Siemens

Siemens 6GT2002-2CE00 MOBY I ASM424 Communication Module

SKU 6GT2002-2CE00

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens
  • Product No.: 6GT2002-2CE00
  • Origin Germany
  • Product Type: CoMMunication Modules
  • Barcode: 85176200
  • Payment: T/T, Western Union
  • Weight: 1.3 kg
  • Dimensions: 0.10cm x 0.10cm x 0.10cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The 6GT2002-2CE00 is a MOBY I communication module, specifically the ASM424 variant, designed to interface identification systems with host controllers. This module facilitates data exchange between MOBY I read/write devices and external systems using a serial interface that supports both RS-232 and RS-422 standards. It implements the 3964R transmission procedure, ensuring reliable communication with PCs, SICOMP systems, and third-party controllers.

The 6GT2002-2CE00 is engineered for efficiency, allowing for the parallel connection of up to four standard read/write devices (SLG 4x, 7x series). This capability enables the module to manage multiple identification points simultaneously, making it a critical component for tracking and logistics applications in industrial environments.

Features

  • MOBY I communication module (ASM424)
  • Dual serial interface: RS-232 / RS-422
  • Supports 3964R transmission procedure
  • Parallel operation support for up to 4 standard SLG 4x / 7x read-write devices
  • Compatible with PCs, SICOMP, and non-Siemens automation controllers

Applications

  • Automated logistics and material handling
  • Production line item tracking
  • Warehouse management and identification systems
  • Integration of RFID identification points with third-party controllers

Technical Specifications

Feature Specification
Brand Siemens
Range MOBY
Subrange I
Product Type Communication Module
Interfaces RS-232, RS-422
Transmission Protocol 3964R
Max. Connected Devices 4 (SLG 4x / 7x)
Weight 1.30 kg
Product Phase Phase-Out
Commodity Code 85176200

Installation Guidelines

  • Mounting: Ensure the module is securely mounted in an appropriate control cabinet or enclosure to protect against environmental contaminants.
  • Interface Configuration: Select the appropriate physical interface (RS-232 or RS-422) based on the host controller requirements and cable length limitations.
  • Wiring: Use shielded, twisted-pair cabling for serial communication to minimize electromagnetic interference (EMI) and ensure data integrity.
  • Addressing: When connecting multiple SLG read/write devices, ensure each device is properly addressed to support parallel operation within the ASM424 configuration.
  • Grounding: Maintain a solid common ground connection between the communication module, the host controller, and the read/write devices to prevent ground loops.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What serial interfaces are supported by the 6GT2002-2CE00?
The module supports both RS-232 and RS-422 serial interface standards.
How many read-write devices can be connected to this module?
It allows for the parallel connection and operation of up to 4 standard SLG 4x or 7x read-write devices.
What communication procedure does this module use?
It utilizes the 3964R transmission procedure for communication with PCs, SICOMP, and third-party controllers.
Is this product still in active production?
No, the 6GT2002-2CE00 is currently in the Phase-Out stage of its product lifecycle.
Reviews

6GT2002-2CE00

Stock & lead time on request

Call
1 of 1

Siemens 6GT2002-2CE00 MOBY I ASM424 Communication Module

Only 8 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6GT2002-2CE00

  • Country of origin:Germany

  • Product Type: CoMMunication Modules

  • Barcode: 85176200

  • Payment: T/T, Western Union

  • Weight: 1300g

  • Dimensions: 0.10cm x 0.10cm x 0.10cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The 6GT2002-2CE00 is a MOBY I communication module, specifically the ASM424 variant, designed to interface identification systems with host controllers. This module facilitates data exchange between MOBY I read/write devices and external systems using a serial interface that supports both RS-232 and RS-422 standards. It implements the 3964R transmission procedure, ensuring reliable communication with PCs, SICOMP systems, and third-party controllers.

The 6GT2002-2CE00 is engineered for efficiency, allowing for the parallel connection of up to four standard read/write devices (SLG 4x, 7x series). This capability enables the module to manage multiple identification points simultaneously, making it a critical component for tracking and logistics applications in industrial environments.

Features

  • MOBY I communication module (ASM424)
  • Dual serial interface: RS-232 / RS-422
  • Supports 3964R transmission procedure
  • Parallel operation support for up to 4 standard SLG 4x / 7x read-write devices
  • Compatible with PCs, SICOMP, and non-Siemens automation controllers

Applications

  • Automated logistics and material handling
  • Production line item tracking
  • Warehouse management and identification systems
  • Integration of RFID identification points with third-party controllers

Technical Specifications

Feature Specification
Brand Siemens
Range MOBY
Subrange I
Product Type Communication Module
Interfaces RS-232, RS-422
Transmission Protocol 3964R
Max. Connected Devices 4 (SLG 4x / 7x)
Weight 1.30 kg
Product Phase Phase-Out
Commodity Code 85176200

Installation Guidelines

  • Mounting: Ensure the module is securely mounted in an appropriate control cabinet or enclosure to protect against environmental contaminants.
  • Interface Configuration: Select the appropriate physical interface (RS-232 or RS-422) based on the host controller requirements and cable length limitations.
  • Wiring: Use shielded, twisted-pair cabling for serial communication to minimize electromagnetic interference (EMI) and ensure data integrity.
  • Addressing: When connecting multiple SLG read/write devices, ensure each device is properly addressed to support parallel operation within the ASM424 configuration.
  • Grounding: Maintain a solid common ground connection between the communication module, the host controller, and the read/write devices to prevent ground loops.

What serial interfaces are supported by the 6GT2002-2CE00?

The module supports both RS-232 and RS-422 serial interface standards.

How many read-write devices can be connected to this module?

It allows for the parallel connection and operation of up to 4 standard SLG 4x or 7x read-write devices.

What communication procedure does this module use?

It utilizes the 3964R transmission procedure for communication with PCs, SICOMP, and third-party controllers.

Is this product still in active production?

No, the 6GT2002-2CE00 is currently in the Phase-Out stage of its product lifecycle.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany
Power source
DC Power

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...