Siemens SIMATIC Panel PC 670 6AV7614-0AF20-0BH0

SKU 6AV7614-0AF20-0BH0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7614-0AF20-0BH0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 35.00 x 25.00 x 25.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a SIMATIC Panel PC 670, model 6AV7614-0AF20-0BH0, manufactured by Siemens. It is an industrial computer designed for human-machine interface (HMI) and control applications. This specific configuration features a 15-inch TFT touch display, a 300 MHz Celeron processor, 128 MB of RAM, and a 40 GB hard drive with an integrated CD-ROM. The unit is pre-installed with the German language version of Windows NT 4.0 and is supplied with a U.S. mains power cable for operation on 115-230V systems.

Features

  • 15-inch TFT color display with integrated touch functionality
  • Powered by a 300 MHz Celeron CPU
  • Equipped with 128 MB of system RAM
  • Includes a 40 GB hard drive for local storage
  • Features a built-in CD-ROM drive
  • Pre-loaded with Windows NT 4.0 operating system (German language)
  • Supplied with a U.S. standard mains power cable

Applications

  • Human-Machine Interface (HMI) for process visualization
  • Supervisory Control and Data Acquisition (SCADA) nodes
  • Machine control and monitoring terminals
  • Factory floor data logging and reporting stations
  • Industrial automation control panels

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC Panel PC 670
Model Number 6AV7614-0AF20-0BH0
Display 15-inch TFT Touch Display
Processor (CPU) Celeron 300 MHz
Memory (RAM) 128 MB
Storage 40 GB Hard Drive, CD-ROM Drive
Operating System Windows NT 4.0 (German Language)
Input Voltage 115-230 V
Included Cable U.S. Mains Cable
Product Lifecycle Status Obsolete
Country of Origin Germany (Estimate)
Package Dimensions 35.00 x 25.00 x 25.00 cm
Shipping Weight 12.00 kg
Harmonized Tariff Code 85371091
ECCN N

Installation Guidelines

CRITICAL WARNING: Electrical Hazard. Installation must be performed by qualified personnel only. Ensure all power sources are de-energized and locked out (LOTO) before commencing any installation, wiring, or maintenance activities. Failure to comply can result in severe injury or death.
  1. 1 Verify that the panel cutout dimensions match the PC 670's mounting requirements. Ensure the mounting surface is flat, clean, and capable of supporting the unit's weight.
  2. 2 Insert the Panel PC into the prepared cutout from the front of the enclosure. Secure it evenly from the rear using all provided mounting clamps. Do not overtighten; apply torque uniformly to create a proper seal.
  3. 3 Connect a dedicated protective earth (PE) or grounding conductor to the designated chassis ground terminal. This connection is critical for safety and noise immunity.
  4. 4 Connect the mains power cable to a stable, correctly rated power source. Ensure the source voltage matches the 115-230 V range of the unit. Route power cables separately from signal and communication lines to prevent interference.
  5. 5 Connect all necessary peripheral and communication cables (e.g., Ethernet, serial, USB). Ensure all connectors are fully seated and secured. After installation is complete, power may be restored to the unit.

FAQ

What operating system is installed on the 6AV7614-0AF20-0BH0?

This unit comes pre-installed with the German language version of Windows NT 4.0.

What are the display specifications for this Panel PC?

It is equipped with a 15-inch TFT color display that features integrated touch screen functionality.

What is the processor and memory configuration?

The device is configured with a 300 MHz Celeron processor and 128 MB of RAM.

Is this a current product from Siemens?

No, the 6AV7614-0AF20-0BH0 is an obsolete product, often used for legacy system maintenance and replacement.

What is included with the Panel PC?

This model is supplied with a U.S. mains power cable for connection to a 115-230V power source.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.