Siemens

Siemens SIMATIC TP177B PN/DP 170 Series HMI Touch Panel

SKU 6AV6642-8BA12-0AB0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV6642-8BA12-0AB0

  • Country of origin:Germany

  • Product Type: HMI Touch Panel

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 2100g

  • Dimensions: 40.6 x 25.4 x 7.6 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a Siemens SIMATIC TP177B PN/DP HMI touch panel, model 6AV6642-8BA12-0AB0, designed for machine-level operator control and monitoring. It features a robust stainless steel front and a membrane-covered display, making it suitable for demanding industrial environments. The unit provides a frontal IP66K protection class, ensuring resistance to high-pressure water jets and dust ingress. This specific part number is a customized design for Hauni, based on the standard 6AV6642-8BA10-0AA0 platform. Please note that this product is in the Phase-Out stage of its product lifecycle.

Features

  • Stainless steel front bezel for enhanced durability and chemical resistance.
  • Membrane-covered display for protection in industrial settings.
  • Frontal ingress protection rating of IP66K.
  • Integrated PROFINET (PN) and PROFIBUS (DP) communication interfaces.
  • Part of the SIMATIC HMI 170 series.
  • Customized design for Hauni applications.

Applications

  • Food and Beverage Processing
  • Pharmaceutical and Packaging Lines
  • Automotive Manufacturing
  • Machine Tool Control
  • Applications requiring frequent wash-downs

Technical Specifications

Specification Value
Brand Siemens
Model SIMATIC TP177B PN/DP
Product Series SIMATIC HMI 170 Series
Product Type HMI Touch Panel
Front Protection Class IP66K
Front Material Stainless Steel
Product Lifecycle Phase Phase-Out
Export Control (ECCN) N
Commodity Code 85371091
Shipping Weight 2.10 kg
Package Dimensions (Calculated) 40.6 x 25.4 x 7.6 cm
Country of Origin Germany (Estimated)
Manufacturer Siemens

Installation Guidelines

CRITICAL WARNING: Risk of Electric Shock

Disconnect all power sources before installation or maintenance. Failure to de-energize equipment can result in severe injury, death, or equipment damage. Installation must be performed by qualified personnel in accordance with all applicable electrical codes.

  1. 1 Verify that the control cabinet and machinery are fully de-energized and locked out/tagged out (LOTO) before beginning work.
  2. 2 Prepare the panel cutout according to the mechanical dimensions specified for the TP177B series. Ensure the mounting surface is clean, flat, and free of debris.
  3. 3 Insert the HMI panel into the cutout from the front. Secure it evenly from the rear using the provided mounting clamps, tightening them to the specified torque to ensure a proper IP66K seal.
  4. 4 Connect the 24V DC power supply to the designated terminals, observing correct polarity. Use appropriately sized conductors for the power connection.
  5. 5 Connect the PROFINET or PROFIBUS DP communication cable to the corresponding port. Ensure proper shielding and grounding of communication cables to prevent interference.
  6. 6 Connect the functional earth (FE) terminal to the control cabinet's central grounding point to ensure proper equipotential bonding and noise immunity.

FAQ

What is the front protection rating of this HMI panel?

The front of the 6AV6642-8BA12-0AB0 is rated IP66K, making it suitable for environments with high-pressure, high-temperature water jets and dust.

What material is the front bezel made of?

This HMI touch panel features a stainless steel front, providing excellent durability and resistance to corrosion and chemicals.

Is this a standard Siemens product?

No, this specific model is a customized design for Hauni, which is based on the standard Siemens TP177B PN/DP platform (6AV6642-8BA10-0AA0).

What is the product lifecycle status for this part number?

This product is in the 'Phase-Out' stage of its lifecycle, meaning it is no longer actively promoted and may have limited availability.

What communication protocols does this panel support?

The 'PN/DP' in the model name indicates that it supports both PROFINET (PN) and PROFIBUS DP (DP) for industrial communication.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.