Triconex

Triconex 3636T Digital Relay Output Module

SKU 3636T

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Triconex

  • Product No.: 3636T

  • Country of origin:United States

  • Product Type: Digital Relay Output Module

  • Payment: T/T, Western Union

  • Weight: 2700g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The 3636T (3636T) by Triconex is a high-density Digital Relay Output Module designed to interface the Tricon controller with non-critical field devices. As a non-triplicated module, the 3636T provides an essential bridge for auxiliary functions that are incompatible with standard high-side solid-state switches, such as annunciator panels, legacy interposing relays, and signal lamps. Despite its non-triplicated output nature, it maintains high system integrity by receiving signals from all three Main Processors. These signals are voted internally before driving the 32 individual relays. In industrial settings like petrochemical plants and power utilities, the 3636T is vital for secondary signaling and monitoring, ensuring that even non-safety-critical data is handled with the precision and diagnostic oversight expected from a TMR (Triple Modular Redundant) system.

Technical Configuration (Deep Dive)

The hardware architecture of the 3636T focuses on transparency and fault detection. Unlike solid-state modules, the 3636T utilizes physical Normally Open (NO) contacts, providing true dry-contact isolation for field circuits. A standout feature is the integrated loopback circuit for each of the 32 points. This circuit continuously verifies the mechanical operation of each relay switch, ensuring it responds correctly to the voted logic even if no field load is currently present. If a diagnostic mismatch is detected, the module immediately triggers the FAULT indicator and a chassis-level alarm, allowing maintenance teams to swap the unit using the supported hot-spare capability without interrupting the rest of the controller's operations.

Technical Specifications

Feature Specification Details
Model 3636T
Brand Triconex (Schneider Electric)
Module Type Relay Output (RO), Non-triplicated
Output Points 32, Non-commoned
Voltage Range 125 VAC/VDC (Maximum)
Current Load 2 A (Maximum per point)
Min Permissible Load 10 mA at 5 VDC
Switching Power 2,000 VA or 150 Watts (Resistive)
Point Isolation 1,500 VDC (1,900 VDC Peak)
Fuses 1 per output (2.5 A fast-acting)
Status Indicators PASS, FAULT, ACTIVE, Point Status
Color Code Silver Blue
Net Weight 2.7 kg
Shipping Weight 3.7 kg

Technical FAQs

Does the 3636T support safety-critical shutdown functions?

No. The 3636T is classified as a non-triplicated module intended for non-critical points. For safety-instrumented functions (SIF) requiring SIL3 integrity, you should utilize triplicated digital output modules like the 3604 or 3625.

What happens if a single relay fails to close?

The 3636T features a loopback circuit that monitors relay state. If the relay fails to follow the voted command from the Main Processors, the module will activate the FAULT light. If a hot-spare is present, the system can transition control to the backup module automatically.

Can I use the 3636T to switch highly inductive loads?

While the module is rated for 2 A, inductive loads (like large solenoid coils) can cause arcing across the NO contacts. It is highly recommended to use external surge suppression (RC snubbers for AC or diodes for DC) to extend the lifespan of the mechanical relays.


Engineering & Installation Guide

  • External Termination Requirement: The 3636T requires a dedicated External Termination Panel (ETP). Ensure the interface cable is securely latched to the Tricon backplane and that the ETP is grounded according to the standard Triconex grounding architecture to prevent EMI interference on the loopback diagnostics.

  • Thermal Considerations: Although the module is rated for 0-60 deg C, switching 32 relays at maximum current simultaneously generates significant heat. Ensure the cabinet has unobstructed airflow and that the PASS and ACTIVE LEDs are visible during routine inspections to monitor module health.

  • Fuse Replacement Protocol: Each output is protected by a 2.5 A fast-acting fuse. If a field short occurs, the fuse will clear to protect the module circuitry. Always disconnect field power at the ETP before attempting to troubleshoot field wiring or replace the module.

Engineering Advantages

The 3636T excels in environments where electrical isolation is paramount. With 1,500 VDC point-to-point isolation, it effectively prevents field-side electrical noise from migrating into the logic backplane. Its silver-blue color coding allows for rapid identification in a crowded rack, reducing the risk of human error during maintenance. Furthermore, its ability to provide dry-contact outputs makes it perfectly downward compatible with older annunciator systems and specialized instrumentation that cannot tolerate the leakage current often associated with solid-state switching modules.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Triconex 3636T Digital Relay Output Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
AC-powered DC Power

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...