Product Overview

The 178B8583 (VLT2840PT4B20SBR0DBF00A00C1) is a versatile and compact frequency converter from the legacy Danfoss VLT 2800 series. Rated for 4.0 kW (5.5 HP) at 380-480V, this drive was specifically engineered to provide high-performance motor control in space-constrained industrial environments. Known for its side-by-side mounting capability and integrated cooling fans, the 178B8583 has been a cornerstone in automated production lines, packaging machinery, and material handling systems. Although this specific model has reached the end of its production lifecycle, it remains a critical component for maintaining existing infrastructure. Note that for new installations or complete system overhauls, Danfoss recommends the 134U3013 (VLT Midi Drive FC 280) as the official high-performance replacement.

Technical Configuration

The VLT 2840 architecture focuses on maximizing torque and precision while maintaining a small physical footprint.

  • Power Capability: Designed for 4.0 kW three-phase motor loads, delivering robust speed control for a wide variety of asynchronous motors.

  • Mains Voltage Range: Supports a broad input window of 380-480V (+/- 10 percent) at 50/60Hz, making it adaptable to global power grids and varying industrial supply conditions.

  • Enclosure Design: Features an IP20 rated chassis (B20), intended for installation within protected electrical control cabinets.

  • Dynamic Braking: Includes an integrated brake chopper, allowing for precise control during rapid deceleration and high-inertia stops.

  • Legacy Reliability: Built with the classic VLT user interface, allowing for rapid parameter cloning and consistent performance in environments with significant electrical noise.

Technical Specifications

Feature Specification
Model 178B8583
Brand Danfoss
Model Code VLT2840PT4B20SBR0DBF00A00C1
Power Rating 4.0 kW / 5.5 HP
Mains Voltage 380 - 480 VAC (3-Phase)
Replacement Model 134U3013 (FC 280)
Enclosure Rating IP20
Brake Chopper Integrated
Operating Temp -10 to 45 deg C (Typical)
Net Weight 3.45 kg
Shipping Weight 5.0 kg

Technical FAQs

Is the 178B8583 still available for new projects?

No, production for this specific model has been stopped. It is primarily available as refurbished stock or for emergency replacement. For all new engineering projects, the 134U3013 (FC-280P4K0T4E20H2BXCXXXSXXXXAX) should be used, as it offers modern communication protocols and higher energy efficiency.

What are the primary differences between this legacy drive and the FC 280 replacement?

While the power ratings are identical, the FC 280 replacement features an upgraded processor, improved thermal management, and enhanced functional safety (STO). The physical dimensions may vary slightly, so verify mounting hole patterns before replacing a 178B8583 in an existing panel.

Does this drive require a separate RFI filter?

The VLT 2800 series was available in various configurations. This specific model should be checked against the model code for integrated filter options; however, in high-precision environments, external RFI filters are often recommended to ensure compliance with modern EMC standards.


Engineering & Installation Guide

  • Cooling Requirements: The VLT 2840 generates heat during full-load operation. Even though the VLT 2800 series supports side-by-side mounting, ensure that the cabinet's internal air temperature does not exceed 45 deg C. Maintain clear vertical pathways for the bottom-to-top airflow generated by the internal cooling fan.

  • Brake Resistor Sizing: For applications involving vertical loads or high-inertia flywheels, an external brake resistor must be connected to the R+ and R- terminals. Failure to install a correctly sized resistor when the brake chopper is active can result in DC-link overvoltage trips.

  • Replacement Strategy: When migrating from the 178B8583 to the 134U3013 (FC 280), do not attempt to directly copy parameter numbers, as the menu structures differ. Use the Danfoss conversion guide to map old parameters to the new VLT Midi Drive settings to ensure identical motor performance.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...