Yokogawa ANB10D-425/CU2N CENTUM VP ESB Bus Node Unit
SKU ANB10D-425/CU2N
In stock
No reviews
12-month warranty
Free returns within 30 days
Manufacturer:
Yokogawa
Product No.:
ANB10D-425/CU2N
Country of origin:Japan
Product Type:
ESB Bus Node Unit
Payment:
T/T, Western Union
Weight:
10000g
Dimensions:
48.26 cm x 22.15 cm x 20.50 cm (W x H x D)
Shipping port:
Xiamen
Warranty:
12 months
The Yokogawa ANB10D-425/CU2N is an ESB Bus Node Unit designed for field control applications within CENTUM VP distributed control systems. It operates as an interface between field analog and contact I/O signals and a Field Control Unit (FCU) via an ESB bus connection, while supplying power to up to 8 installed I/O modules. Built with dual-redundant power supplies and dual ESB bus interfaces, the ANB10D-425/CU2N ensures continuous communication, field transmitter power distribution, and signal processing for critical industrial process control environments.
Features
Interfaces field analog and contact I/O signals directly with a Field Control Unit via an ESB bus connection.
Houses up to 8 field I/O modules and provides internal power distribution to modules and connected field transmitters.
Includes dual-redundant power supply module slots and dual SB401 ESB Bus Interface Slave Module slots.
Standard 19-inch rack-mount hardware layout using four M5 screw attachment locations.
Configured with a 220–240 V AC power input and standard non-explosion protection design.
Ships with the /CU2N dual-connector unit option for connecting dual-redundant ESB bus lines.
Applications
DCS process automation in refining, petrochemical, and chemical facilities
Thermal and nuclear power generation control systems
Industrial water, wastewater, and utility monitoring platforms
Continuous manufacturing process control and Field Control Unit node expansion
Ordering Information
Model
Suffix / Option Code
Description
ANB10D
Node Unit for Dual-Redundant ESB Bus
Power Supply
-4
Dual-redundant power supply
Voltage
2
220 - 240 V AC power supply
Protection
5
Basic type with no explosion protection
Option
/CU2N
Connector Unit for ESB Bus [part No.: S9562FA (2 pieces)]
Technical Specifications
Parameter
Specification
Manufacturer
Yokogawa Electric Corporation
Model
ANB10D-425/CU2N
Node Unit Type
Node Unit for Dual-Redundant ESB Bus
Power Supply Type
Dual-redundant power supply
Input Voltage
220–240 V AC
Power Frequency
50/60 Hz
Power Consumption
230 VA, 120 W
I/O Module Capacity
Maximum 8 modules
Power Supply Modules
PW481, PW482, or PW484 (2 modules for dual-redundant configuration)
ESB Bus Interface Modules
SB401 ESB Bus Interface Slave Module (2 modules for dual-redundant configuration)
Connector Unit Option
/CU2N (2 x S9562FA ESB Bus Connector Units)
Power Terminal Screw Type
M4 screws
Mounting
19-inch Rack Mounting (M5 x 4 screws)
Dimensions (W x H x D)
482.6 mm x 221.5 mm x 205 mm
Weight
10 kg (including 8 I/O Modules)
Connections/Interfaces
Component / Terminal
Function
Power Supply Terminals
M4 screw terminals for 220–240 V AC dual power input connections
ESB Bus Connectors (/CU2N)
Dual S9562FA connector units for dual-redundant ESB bus cable integration
I/O Module Slots 1–8
Field interface slots for analog and contact I/O modules
Power Module Slots
Dedicated dual slots for PW481/PW482/PW484 power supply modules
Slave Module Slots
Dedicated dual slots for SB401 ESB Bus Interface Slave Modules
Installation Guidelines
19-Inch Rack Mounting: Mount the unit on a standard 19-inch rack using four M5 screws and four S9049PM insulating bushes included as accessories.
Power Terminal Wiring: Secure field power wiring to the dual power supply terminals using M4 terminal screws.
Barrier Insulation Partition: If installing I/O modules with built-in intrinsic safety barriers, install an insulating partition (Part No. T9083NA) at the 8th slot.
Bus Coupler Placement: Ensure the host Field Control Unit uses EC401 or EC402 ESB Bus Coupler Modules installed in slots 7 and 8 to interface with the node unit.
Compliance and Certifications
CE Marking: Compliant (for 220–240 V AC power supply)
EMC Standards: CE Marking, C-Tick Marking, KC Marking
Hazardous Location: FM Non-Incendive (for 220–240 V AC power supply)
FAQ
How many I/O module slots are provided on the node unit?
The node unit supports a maximum of 8 field I/O modules.
What is the primary power supply requirement for this specific model configuration?
The device operates on a 220–240 V AC power supply at 50/60 Hz frequency.
Which interface modules establish dual-redundant ESB bus communication?
The node unit utilizes two SB401 ESB Bus Interface Slave Modules along with the /CU2N dual connector unit.
A field replacement guide for GE Fanuc IC200MDL650 covering revision-dependent negative logic, four common groups, 24 VDC thresholds, input filtering, carrier checks and commissioning records.
A field-focused IC697CPX935 replacement guide covering fast memory, firmware-dependent serial behavior, rack power, cooling, I/O architecture and backup records.
A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.