1 จาก 3

Bently Nevada 3500/05-01-01-00-00-00 System Chassis Rack

Bently Nevada 3500/05-01-01-00-00-00 System Chassis Rack

Only 5 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 3500/05-01-01-00-00-00

  • Country of origin:สหรัฐอเมริกา

  • Product Type: System Chassis Rack

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 13600g

  • Dimensions: 482.60 mm x 265.94 mm x 349.25 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

 

Description

The 3500/05-01-01-00-00-00 is a full-size, 19-inch System Chassis Rack manufactured by Bently Nevada (a Baker Hughes business) designed as the foundational structural framework for the 3500 Series Machinery Protection System. This equipment serves as the physical enclosure and backplane hub that houses all the core 3500 machinery vibration monitors, transient data interfaces, and system power supplies. It provides the vital high-speed digital communications bus backplane allowing distinct slots to exchange data seamlessly, while simultaneously supplying a highly filtered internal power distribution grid to each individual hardware module.

The exact hardware layout code 3500/05-01-01-00-00-00 specifically details a 19-inch full-size structural framework containing 14 available instrumentation slots (excluding the dedicated left-hand utility power and rack interface module positions). It features a Panel Mount structural format option, meaning it is optimized to drop directly into custom rectangular cut-outs on cabinet doors or control panels where it secures firmly using the heavy-duty mechanical clamps included with the assembly. All underlying input/output field terminations, transducer cables, and back-end I/O modules are fully accessible directly from the rear of the panel structural layout. This model contains no special hazardous agency approvals and is standard production series hardware.

Features

  • Central high-speed communication backplane enabling real-time processing interaction between protection cards.
  • Full-size 19-inch instrumentation architecture offering 14 discrete, customizable module expansion slots.
  • Panel mount design using heavy-duty mounting clamps for flush integration on panel faceplates.
  • Rear-access configuration ensuring field sensor loops and I/O cards can be wired without opening the front chassis.
  • Rigid industrial-grade structural metal build to damp ambient high-frequency vibration and shield against magnetic interference.

Applications

  • Primary localized equipment rack holding machinery protection cards for large utility steam and gas turbines.
  • Plant-wide central safety interlock and predictive maintenance monitoring hub on high-vibration compression trains.
  • Multi-channel vibration marshalling enclosures used inside harsh oil and gas refinery or petrochemical control rooms.

Option String Breakdown

Option Code Slot Selected Option Value Technical Detail
Model Number 3500/05 System Rack Product Series
A: Rack Size -01 19-inch Rack (14 usable module slots)
B: Mounting Options -01 Panel Mount Option, Full-Size Rack format
C: Agency Approval Option -00 None (Standard safety area classification)
D: Reserved Option -00 None (Factory baseline configuration)
E: European Compliance -00 None (Standard configuration)

Technical Specifications

Parameter Detail
Manufacturer Bently Nevada (Baker Hughes / GE)
Part Variant ID 3500/05-01-01-00-00-00
Product Category Condition Monitoring System Chassis Rack
Total Available Slots 14 slots for standard monitors, plus 2 dedicated left positions for Power/RIM
Physical Mounting Profile Flush panel cutout integration with rear-facing I/O access
Overall Framework Width 482.60 mm (Standard 19-inch layout)
Overall Framework Height 265.94 mm
Overall Framework Depth 349.25 mm
Average Component Weight Approximately 13.6 kg (30 lbs) to 20.4 kg (45 lbs) empty
Enclosure Material Base Heavy-gauge aluminum and structural sheet metal alloys
Ground Reference Target Dedicated copper ground lugs provided on the chassis rear grid

Connections/Interfaces

Structural Interface Function Assignment
Internal Bus Backplane High-density pin array distributing internal DC power and control logic between slots
Rear I/O Panel Space Open architecture slots receiving the slide-in external field sensor termination blocks
Chassis Ground Lug Heavy-duty copper stud point connecting the rack frame to structural earth safety grounds

Installation Guidelines

  • Panel Cutout Clearance: Prepare a clean rectangular panel cutout matching the exact dimensions specified by Bently Nevada documentation. Ensure sufficient depth behind the panel face for I/O module clearance and cable bend radiuses.
  • Clamping System Engagement: Insert the rack assembly from the front of the cutout panel. From the inside or rear, hook the provided fastening clamps into the chassis side tracks and tighten them uniformly until the front face gasket seals firmly against the panel surface.
  • Dedicated Utility Slot Rules: Remember that the far left slots are dedicated exclusively to the power supply modules (such as the 3500/15) and the Rack Interface Module (3500/22M). Standard vibration monitors cannot be inserted into these utility slots.
  • Chassis Earth Ground Link: Connect a heavy-gauge copper grounding wire from the main chassis earth stud to the primary electrical ground grid of the control room panel enclosure to block electrical noise.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3500/05-01-01-00-00-00 System Chassis Rack

Which specific modules must be placed in the far left positions of the 3500/05 rack?

The rack power supply modules (such as the 3500/15) and the Rack Interface Module (RIM, such as the 3500/22M) are required to occupy the far-left slot positions of the chassis.

What is the key difference between the Panel Mount option and a standard Rack Mount option for this chassis?

The Panel Mount option mounts directly inside custom rectangular panel cutouts using included mechanical clamps, with access to wiring from the rear. The Rack Mount option is engineered to bolt directly onto standard standard 19-inch EIA open relay rails.

How many functional monitoring card slots are accessible on a full-size 3500/05-01 chassis?

A full-size 19-inch system rack provides exactly 14 usable monitor module expansion slots, excluding the dedicated utility slots located on the far left side.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีดำ
Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...