1 จาก 3

Bently Nevada 3500/33 149986-01 16-Channel Relay Module

Bently Nevada 3500/33 149986-01 16-Channel Relay Module

Only 7 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 3500/33 149986-01

  • Country of origin:สหรัฐอเมริกา

  • Product Type: 16-Channel Relay Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1300g

  • Dimensions: 241 mm x 24.4 mm x 242 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

The 3500/33 with spare part number 149986-01 is a full-height module that provides 16 independent programmable relay outputs for machinery protection and control switching. This 3500/33 149986-01 module functions within the 3500 Series Machinery Protection System and installs into any standard slot to the right of the Transient Data Interface (TDI) module. Each relay output features independent voting logic configuration and dedicated Alarm Drive Logic, which processes alert, danger, and Not-OK statuses derived from any combination of monitor channels across the rack via the configuration software. Internal communication link tracking is visually monitored via integrated front panel status indicators.

Features

  • 16 fully independent single-pole double-throw (SPDT) relay output channels.
  • Custom voting logic and Alarm Drive Logic supporting complex AND/OR logic configurations.
  • Integrated onboard 250 Vrms arc suppressors installed as a standard protection feature.
  • Switch-selectable operations for Normally De-energized (ND) or Normally Energized (NE) modes in groups of four channels.
  • Visual status verification via OK, TX/RX, and individual channel alarm LEDs.

Applications

  • Automated machinery trip and emergency shutdown logic initialization.
  • Interlocking and annunciator panel control in heavy industrial processing.
  • Critical alarm state relay signaling for turbines, large pumps, and industrial compressors.

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Model Number 3500/33
Spare Part Number 149986-01
Product Type 16-Channel Relay Control Module
Power Consumption 5.8 watts typical
Relay Contact Type Single-pole Double-throw (SPDT), epoxy-sealed
Relay Arc Suppressor 250 Vrms standard
Relay Contact Life 10,000 cycles
Standard System Min Load 100 mA @ 5 Vdc
Standard DC Max Load 5 A, 70 W @ 24 Vdc, 10 W @ 48 Vdc, 9 W @ 60 Vdc, 125 Vdc max
Standard AC Max Load 5 A, 1200 VA, 250 Vac max
Failsafe System Max DC 5 A, 30 Vdc max
Low Current System Min Load 1 mA @ 1 Vdc (Gold-plated contacts)
Low Current System Max DC 100 mA @ 48 Vdc
Low Current System Max AC 5 mA max (Specific to AC up to 120Vac)
Main Module Dimensions 241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in)
I/O Module Dimensions 241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Main Module Weight 0.7 kg (1.6 lb)
I/O Module Weight 0.4 kg (1.0 lb)
Rack Space Required 1 full-height front slot (Main), 1 full-height rear slot (I/O)
Country of Origin United States

Installation Guidelines

  • Slot Placement: Seat the full-height main control module into any available chassis slot located directly to the right of the primary TDI module.
  • Redundant Pairs: Pair the main front-panel module with its corresponding 16-channel relay I/O module positioned directly behind it in the rear chassis space.
  • Logic Programming: Configure the voting logic structures and operational parameters via the 3500 Rack Configuration Software prior to putting the instrumentation loop online.
  • Operation Mode Setup: Set the physical switches to select between Normally De-energized (ND) and Normally Energized (NE) setups for each four-channel group based on plant safety specifications.
  • Hazardous Voltage Warning: Ensure all field terminal wiring points are completely isolated from source power lines prior to installation or maintenance to eliminate high-voltage shock risks.
  • Explosion Hazard Precaution: Do not connect or disconnect any components or field terminations while the active instrumentation circuit is live unless the surrounding zone is verified to be non-hazardous.
Key Features:

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3500/33 149986-01 16-Channel Relay Module

Where can this 16-channel relay module be installed inside the rack?

The module is full-height and can be placed in any of the slots located to the right of the Transient Data Interface (TDI) module.

How are the Normally Energized or Normally De-energized operations chosen?

The relay operations are switch-selectable on the hardware in four distinct groups of four channels each.

What is the maximum current rating for standard relays in AC applications?

Standard relays support a maximum switched current of 5 A and a maximum switched power of 1200 VA, up to a maximum voltage of 250 Vac under resistive loads.

What happens if standard electrical loads are applied to gold-plated low current relays?

For low current gold-plated relays, the maximum switching current before sustaining component damage is strictly limited to 5 mA for AC up to 120Vac.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีขาวอมเทา เงิน
Country of origin
สหรัฐอเมริกา
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...