1 จาก 1

Honeywell TSDO-0824 Safety Manager Safe Digital Output FTA

Honeywell TSDO-0824 Safety Manager Safe Digital Output FTA

Only 3 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: TSDO-0824

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Field Termination Assembly Module

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Dimensions: 170 x 70 x 64 mm (6.72 x 2.76 x 2.52 in)

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

The Honeywell TSDO-0824 is a high-reliability Safe Digital Output Field Termination Assembly (FTA) module specifically engineered for integration within the Honeywell Safety Manager platform. This module acts as the dedicated physical and electrical interface connecting the system interconnection cable SICC-0001/Lx directly to external field circuitry via robust onboard screw terminals.

Designed to support critical safety-instrumented functions, the TSDO-0824 handles the eight independent channels of a single or redundant pair of SDO-0824 safe digital output modules. The assembly features a universal snap-in mounting provision designed for standard DIN EN rails, offering structured, secure, and vibration-resistant field terminal assignments for high-availability industrial safety applications.

Features

  • Seamlessly interfaces 8 independent safe digital output channels to the field.
  • Designed as the direct terminal companion for the SICC-0001/Lx system interconnection cable.
  • Fully supports redundant pairing topologies with SDO-0824 safety output modules.
  • Integrated universal snap-in hardware for secure and direct DIN rail mounting.
  • Durable built-in screw terminal blocks provide standard, gas-tight field wiring connections.
  • Confirmed high electrical compliance matching overvoltage category 3 parameters.

Applications

  • Safety Instrumented Systems (SIS)
  • Emergency Shutdown Systems (ESD)
  • Burner Management Systems (BMS)
  • High-integrity Fire and Gas (F&G) output systems
  • Distributed Control System (DCS) safety loop interlocks

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Product Number TSDO-0824
Product Type Safe Digital Output FTA
System Series Safety Manager
Number of Channels 8
Maximum Voltage 36 Vdc – IEC 1010 (1990), overvoltage category 3
Maximum Continuous Current per Channel 1.5 A
Actual Maximum Current Defined by connected output module
DIN EN Rails TS32 / TS35 x 7.5
Used Rail Length 171 mm (6.73 in)
Screw Terminals Max Wire Diameter 2.5 mm² (AWG 14)
Screw Terminals Strip Length 7 mm (0.28 in)
Screw Terminals Tightening Torque 0.5 Nm (0.37 ft-lb)
Module Dimensions (L x W x H) 170 x 70 x 64 mm (6.72 x 2.76 x 2.52 in)
Shipping Weight 3 Kg
Country of Origin Netherlands

Installation Guidelines

  • DIN Rail Installation: Snap the module firmly onto standard TS32 or TS35 x 7.5 DIN EN rails. Verify that the targeted rail segment leaves at least 171 mm of usable horizontal space to properly accommodate the base alignment.
  • Cable Termination: Plug the multi-pin interface plug of the SICC-0001/Lx system interconnection cable completely into the module's onboard SIC header to establish the internal link with the SDO-0824 output modules.
  • Field Wiring Connection: Carefully strip field conductor ends to a precise length of 7 mm (0.28 in). Insert the conductors into the terminal blocks (accepting up to 2.5 mm² / AWG 14 max wire size) and securely tighten the screws to a nominal torque of 0.5 Nm (0.37 ft-lb).
  • Enclosure Protection: Mount the assembly within a clean, climate-controlled electrical panel or marshalling cabinet to provide appropriate moisture, environmental dust protection, and effective shielding against industrial EMI/RFI noise.

Compliance and Certifications

  • CE
  • TUV
  • UL
  • CSA
  • FM

FAQ

What is the primary role of the TSDO-0824 module in a safety system?

It acts as the physical field termination assembly interface that bridges the Honeywell Safety Manager system interconnection cabling to the external field equipment wiring.

How many output channels are built into this termination assembly?

The module is equipped with exactly 8 safe digital output channels.

Which system cable must be used to connect this FTA to the system rack?

This module requires the standard SICC-0001/Lx system interconnection cable.

Can this field termination module handle redundant output signals?

Yes, it can seamlessly accommodate the eight combined channels of a redundant pair of SDO-0824 modules.

What is the maximum absolute voltage limit permitted for the field contacts?

The maximum voltage limit is defined as 36 Vdc under IEC 1010 (1990) overvoltage category 3 parameters.

Does the TSDO-0824 strictly limit channel current to 1.5 A?

While the hardware continuous current limit per channel is 1.5 A, the actual maximum current limit is determined by the specific output module connected upstream.

What specific profile types of DIN EN rails can this module be snapped onto?

The integrated universal snap-in assembly is fully compatible with TS32 and TS35 x 7.5 DIN EN rails.

How much horizontal space on the DIN rail does the unit require?

The module has a specified used rail length of 171 mm (6.73 inches).

What is the required insulation stripping length for preparing field wiring?

External field wires must be stripped to an exact length of 7 mm (0.28 inches) before termination.

What torque level should be applied when securing the field screws?

All onboard field screw terminals must be tightened to a torque rating of 0.5 Nm (0.37 ft-lb).

What is the maximum allowable wire gauge size for the terminal block?

The terminal blocks accept a maximum solid or stranded conductor diameter up to 2.5 mm², which matches AWG 14.

What independent product testing certifications does this hardware hold?

The field termination assembly holds official, fully verified approvals from CE, TUV, UL, CSA, and FM.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell TSDO-0824 Safety Manager Safe Digital Output FTA

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
ส้ม สีเขียว
Country of origin
สหรัฐอเมริกา
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...