1 จาก 1

Omron 3G3JZ-A2015 SYSDRIVE 3G3JZ 3-Phase AC Inverter

Omron 3G3JZ-A2015 SYSDRIVE 3G3JZ 3-Phase AC Inverter

Only 10 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: 3G3JZ-A2015

  • Country of origin:ญี่ปุ่น

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Providing precise motor speed control within compact industrial architectures, the Omron 3G3JZ-A2015 variable frequency drive is engineered for three-phase 200V applications demanding high operational efficiency. This SYSDRIVE 3G3JZ series inverter supports up to 1.5 kW motor capacities, delivering reliable performance and dynamic torque response. Built with an IP20-rated protective enclosure, it is designed for secure panel integration or closed wall-mount configurations, making it a rugged choice for demanding machine control panels.

Key Features

  • Precise Output Rating: Fully optimized to drive 3-phase AC motors up to 1.5 kW capacity.
  • Resilient Panel Enclosure: Rated IP20 minimum, suitable for space-saving side-by-side mounting.
  • Efficient Thermal Management: Engineered layout for efficient heat dissipation inside closed control panels.
  • User-Friendly Interface: Simplifies on-site calibration, parameter setting, and fault diagnostics.

Applications

  • Conveyor and Material Handling: Provides smooth starting torque and precise velocity control.
  • Pumping and HVAC Systems: Regulates fluid and air flow velocities to conserve energy.
  • Packaging Machinery: Handles rapid stop/start cycles with predictable deceleration ramps.
  • Automated Production Lines: Seamlessly integrates with master PLC architectures via discrete and analog control loops.

Technical Specifications

Parameter Specification Value
Manufacturer Omron
Model Code 3G3JZ-A2015
Product Series SYSDRIVE 3G3JZ
Input Voltage Class 3-Phase AC 200V Level (200 to 240 VAC)
Max Applicable Motor Capacity 1.5 kW (2.0 HP)
Enclosure Rating IP20 (Panel Mounting/Closed Wall Mounting)
Cooling Method Forced air cooling / Fan cooled
Shipping Weight (Calculated) 3.0 kg

Connections and Interfaces

Terminal Symbol Description and Terminal Function
R/L1, S/L2, T/L3 Main circuit AC power supply input terminals (3-phase 200 to 240 VAC)
U/T1, V/T2, W/T3 Inverter output terminals connected directly to the 3-phase AC motor
+1, +2 / B1, B2 DC reactor connection and external dynamic braking resistor terminals
Ground (PE) Safety earth ground terminal (must be grounded securely to prevent ESD/EMI issues)

Empirical Engineering Insights

Alternative Models & Compatibility

The legacy 3G3JZ series can often be upgraded to newer Omron MX2 (3G3MX2) or RX series variable frequency drives. When migrating, verify physical dimensional differences, terminal positioning, and Modbus control register addresses, as legacy 3G3JZ parameters will require manual mapping to the newer CX-Drive configurations.

Application Pitfalls & Engineering Notes

Avoid installing the unit in areas of high humidity or where conductive metallic dust is present. Ensure a minimum clearance of 120 mm above and below the drive housing when installing inside a closed electrical panel to allow natural convection, even when forced-air cooling fans are operational. Running the drive close to its thermal thresholds significantly shortens the operational lifespan of the internal DC bus capacitors.

Commissioning & Wiring Tips

To eliminate electromagnetic interference (EMI) issues with nearby low-voltage analog control wiring (such as 4-20mA or 0-10V PLC output loops), always run power input/output cables and signal cables in separate conduits. Additionally, use shielded, symmetrical motor cabling and ground the shield at both the inverter PE terminal and the motor frame.

Installation Guidelines

CRITICAL WARNING: Hazardous voltages remain present within the drive's internal capacitors even after disconnecting the AC input supply. Disconnect all electrical power sources and wait at least 10 minutes for the charge to bleed off. Confirm zero voltage across the DC bus terminals using a trusted, calibrated digital voltmeter before touching any wiring connections or electronic components.
1

Mount the inverter vertically to a flat, metallic panel backplate to assist with grounding and heat dissipation.

2

Terminate input power conductors to terminals R/L1, S/L2, and T/L3. Connect motor lines to U/T1, V/T2, and W/T3.

3

Configure control signals (source/sink parameters) based on your system design requirements before energizing the drive.

What is the maximum motor output rating supported by this model?

This model is rated for three-phase AC motors with a maximum capacity of 1.5 kW (equivalent to 2.0 HP).

Does this model support single-phase input voltage?

No, this specific model requires a 3-phase AC 200V to 240V supply. Do not power it with single-phase lines as it will trigger phase loss and under-voltage protection faults.

What is the enclosure protective rating for this VFD?

It features an IP20 minimum-rated enclosure, meaning it is protected against solid foreign objects greater than 12.5 mm but provides no protection against water ingress. It must be installed within an appropriate control cabinet.

What is the correct mounting orientation inside an enclosure?

Always mount the unit vertically on a rigid panel, leaving at least 120 mm clearance above and below the housing to maintain proper air circulation and cooling performance.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
ญี่ปุ่น

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...