Omron 3G3JZ-A2022 SYSDRIVE 3G3JZ Series 3-Phase Variable Frequency Drive

Omron 3G3JZ-A2022 SYSDRIVE 3G3JZ Series 3-Phase Variable Frequency Drive

Only 6 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: 3G3JZ-A2022

  • Country of origin:ญี่ปุ่น

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Designed for efficient motor speed control and space-saving control cabinet installations, the Omron 3G3JZ-A2022 delivers variable frequency regulation for three-phase AC induction motors up to 2.2kW. Operating on a three-phase AC 200V voltage class, this compact SYSDRIVE 3G3JZ Series inverter features an integrated IP20-rated chassis designed for direct panel or closed wall-mounting configurations, offering high reliability in demanding industrial environments.

Features

  • Optimized for maximum applicable motor capacities up to 2.2kW.
  • Panel-mounting design with a minimum IP20 enclosure rating for secure cabinet housing.
  • High-torque compensation and precise speed control across the operating spectrum.
  • Three-phase AC 200V level power architecture ideal for standard industrial motor systems.
  • Compact footprint allowing high-density side-by-side DIN rail or backplate configuration.

Applications

  • Conveyor drive controls and material handling systems.
  • Industrial pump, fan, and ventilation speed regulation.
  • Packaging, labeling, and automated bottling machinery.
  • Machine tool auxiliary axis control.

Technical Specifications Table

Parameter Specification
Manufacturer Omron
Model Code 3G3JZ-A2022
Series SYSDRIVE 3G3JZ Series
Voltage Class 3-phase AC200V (200V Level)
Max. Applicable Motor Capacity 2.2 kW
Enclosure Rating Panel-mounting / Closed wall mounting (IP20 minimum)
Shipping Weight 3.0 kg

Alternative Models & Compatibility

For modernized systems, the legacy SYSDRIVE series can often be migrated to newer Omron MX2 (3G3MX2) or RX2 series drives. Ensure to verify mounting hole patterns and control terminal differences when substituting older installations with active Omron lines.

Application Pitfalls & Engineering Notes

This unit relies on heat sink convection. To prevent thermal faults (such as Overheat "OH" trip conditions), maintain a minimum mounting clearance of 100mm on the top/bottom and 50mm on the sides when designing layout inside sealed IP20 electrical enclosures.

Commissioning & Wiring Tips

Always install a dedicated noise filter on the line side input to mitigate high-frequency interference. Ensure that control signals (such as 0-10V or 4-20mA speed references) are run using shielded twisted-pair cables with the shield grounded only at the drive end.

Installation Guidelines

CRITICAL WARNING

Risk of severe electrical shock. Ensure all incoming AC mains power is disconnected and locked out. Wait a minimum of 10 minutes for internal high-voltage DC bus capacitors to discharge fully before removing the wiring cover or making terminal adjustments.

1 Mount the inverter vertically on a flat, non-flammable surface inside an appropriate cabinet enclosure.
2 Connect the incoming 3-phase AC 200V supply cables to input terminals R/L1, S/L2, and T/L3.
3 Connect the motor leads to the drive output terminals U/T1, V/T2, and W/T3. Ensure a solid chassis safety ground is connected.

What is the primary input voltage requirement for this variable frequency drive?

The Omron 3G3JZ-A2022 requires a 3-phase 200V to 240V AC input power supply.

What is the maximum motor rating that this inverter can support?

This inverter is rated to support three-phase AC induction motors with a maximum capacity of 2.2kW.

What is the environmental protection rating of the 3G3JZ-A2022?

It features an IP20-rated enclosure designed primarily for secure panel mounting or closed electrical wall cabinet environments.

How long should I wait after powering down before conducting maintenance?

You must wait at least 10 minutes to allow the high-voltage internal DC bus capacitors to discharge safely before servicing any terminals.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
ญี่ปุ่น

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...