Facilitating safe system expansion and precise timing control across complex machine layouts, the Omron G9SX-AD322-T150-RC flexible safety unit delivers advanced safety logic integration without complex programming. This advanced safety controller features solid-state safety outputs configured for both instantaneous shut-off and controlled deceleration profiles. Built with a spring-cage terminal interface, the hardware ensures gas-tight, vibration-proof electrical terminations ideal for high-stress manufacturing environments.

Features

  • Configurable OFF-delay times up to 150 seconds via synchronized front-panel rotary dials.
  • Three instantaneous solid-state safety outputs and two OFF-delayed safety outputs for staged system shutdowns.
  • Spring-cage (tension clamp) terminal blocks for rapid installation and long-term connection reliability.
  • Two auxiliary outputs providing clear diagnostics and machine status communication directly to control PLCs.
  • Logical AND connection capability to cascade multiple safety units while preserving safety integrity levels.

Applications

  • Robotic work cell safety integration requiring delayed interlocking guard access until complete arm deceleration.
  • Emergency stop circuits necessitating controlled motor ramp-down prior to physical brake application.
  • Complex packaging line synchronization requiring zoned safety shutdown capabilities.
  • Safety light curtain integration paired with automated process gates.

Technical Specifications

Manufacturer Omron
Model Reference G9SX-AD322-T150-RC
Unit Classification Advanced Safety Unit
Rated Supply Voltage 24 VDC
Operating Voltage Range 20.4 to 26.4 VDC (-15% to +10% of nominal)
Power Consumption 4.0 W maximum
Instantaneous Safety Outputs 3 Semiconductor (P-channel MOS FET)
OFF-delayed Safety Outputs 2 Semiconductor (P-channel MOS FET)
Auxiliary Outputs 2 PNP Transistor (100 mA maximum)
Max. OFF-delay Configuration 150 seconds
Load Current (1 to 2 active outputs) 1.0 A DC maximum per output
Load Current (3 or more active outputs) 0.8 A DC maximum per output
Safety Input Impedance Approximately 2.8 kOhms
Connection Style Spring-cage terminals (RC model)
Vibration Resistance 10 to 55 to 10 Hz, 0.375 mm single amplitude
Net Unit Weight 0.2 kg
Shipping Weight 1.5 kg

Connections and Interfaces

Terminal Block Designation Functional Circuit Assignment
A1, A2 Power supply connections (24 VDC and 0 VDC reference)
T11, T12 / T21, T22 Dual-channel safety sensor/switch inputs
T31, T32 Feedback loop and manual reset inputs
S14, S24, S34 Instantaneous safety semiconductor outputs
S44, S54 OFF-delayed safety semiconductor outputs
Y1, Y2 Auxiliary solid-state outputs for diagnostic communication

Empirical Engineering Insights

Alternative Models & Compatibility

The G9SX-AD322-T150-RC features spring-cage terminals, which represent the direct structural and electrical alternative to the G9SX-AD322-T150-RT model (which utilizes traditional screw terminals). Because both variants share an identical internal logic engine and mounting footprint, they are completely interchangeable from a system engineering standpoint. However, the terminal plugs themselves cannot be directly cross-connected due to physical housing differences; wiring must be re-terminated with ferrules for optimal performance in the RC unit.

Application Pitfalls & Engineering Notes

When configuring the OFF-delay timing on the G9SX-AD322-T150-RC, engineers must adjust both rotational switches on the front panel to the exact same delay coefficient. If the two dials do not match precisely, the unit detects an asymmetrical layout parameter and enters a lock-out fault status, disabling all safety outputs. To reset this fault condition, set both dials to identical configurations and cycle the main 24 VDC supply voltage.

Commissioning & Wiring Tips

For optimal termination reliability, utilize insulated wire ferrules with a crimp length of 10 mm. Avoid using bare stranded copper wire in the spring-cage terminals, as single stray strands can cause local resistance faults or physical short-circuits. Utilize a 2.5 mm flat-head screwdriver inside the actuation slot to open the internal tension clamp during termination or diagnostic procedures.

Installation Guidelines

CRITICAL WARNING: Prior to attempting installation, configuration, or physical wiring adjustments on the safety unit, isolate and lock out all upstream electrical power sources. Verify the absence of residual voltage across all power and output lines before proceeding to avoid severe electrical hazards.
  1. 1
    DIN-Rail Mounting: Snap the safety unit securely onto standard 35 mm DIN rail inside a protective electrical enclosure rated for the application environment (minimum IP54 rating recommended).
  2. 2
    Terminal Block Connection: Insert the designated ferruled wire leads into the spring-cage terminals by depressing the adjacent actuation slot using a dedicated 2.5 mm flat tool.
  3. 3
    Time-Delay Calibration: Configure the integrated rotary switches to align with the desired machine deceleration delay profile, ensuring both front-panel dials are dialed to the identical numeric value.
  4. 4
    Functional System Test: Energize the module, verify the green LED diagnostic indications, and execute a controlled system verification test to confirm active-low safety response profiles.

What happens if the two OFF-delay rotary dials do not match?

If there is any setting mismatch between the dual dials on the front panel, the safety unit will identify this as an asymmetrical layout parameter. This places the unit into a lock-out fault mode, immediately disabling all safety outputs. Both dials must be matching and power must be cycled to clear this state.

Can I replace a G9SX-AD322-T150-RT unit with this RC variant?

Yes. The G9SX-AD322-T150-RC is electrically identical to the -RT model and shares the exact same logic functions. The only physical difference is that the 'RC' variant features spring-cage terminals, while the 'RT' variant features screw terminals.

What are the output load limits when multiple semiconductor outputs are active?

When using 2 or fewer outputs, each output can handle a maximum load current of 1.0 A DC. When using 3 or more safety outputs simultaneously, the maximum allowable load current drops to 0.8 A DC per output to prevent thermal overload.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
ญี่ปุ่น

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...