1 จาก 1

Weidmuller 8965370000 ACT20X-2HDI-2SDO-RNO-S Isolating Switch Amplifiers

Weidmuller 8965370000 ACT20X-2HDI-2SDO-RNO-S Isolating Switch Amplifiers

Only 10 item(s) left in stock
  • Manufacturer: Weidmuller

  • Product No.: 8965370000

  • Country of origin:เยอรมนี

  • Product Type: Isolating Switch Amplifiers

  • Payment: T/T, Western Union

  • Weight: 190g

  • Dimensions: 117.2 mm x 22.5 mm x 113.6 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Designed for intrinsic safety applications, the Weidmuller 8965370000 functions as a highly reliable isolating switch amplifier to transmit digital signals from hazardous areas (Zone 0, 1, 2) to safe areas. This 2-channel module is engineered to process signals from NAMUR sensors or mechanical contacts located in explosive atmospheres, providing complete galvanic isolation between the input, output, power supply, and alarm contacts.

The ACT20X-2HDI-2SDO-RNO-S features integrated line fault detection (LFD) to monitor the input circuits for wire breaks or short circuits. In the event of a fault, the device triggers an alarm relay, ensuring rapid diagnostics and minimizing system downtime. Configuration is easily managed via standard FDT/DTM software, allowing precise customization of operational parameters to match specific process requirements.

Features

  • Dual-channel signal isolation and transmission from Ex to non-Ex zones.
  • Intrinsically safe input circuits compatible with NAMUR sensors and mechanical switches.
  • Two normally open (NO) relay outputs for reliable signal switching.
  • Comprehensive line fault detection (LFD) for short-circuit and wire-break monitoring.
  • FDT/DTM software configuration for flexible parameter adjustment.
  • Complete galvanic isolation between input, output, power supply, and alarm contacts.
  • Compact 22.5 mm DIN-rail mountable housing to optimize cabinet space.

Applications

  • Chemical and petrochemical processing plants.
  • Oil and gas extraction, refining, and distribution facilities.
  • Water and wastewater treatment automation.
  • Hazardous area digital signal isolation (Zone 0, 1, 2, and Class I Div 1/2).

Technical Specifications

Manufacturer Weidmuller
Part Number / Model 8965370000 (ACT20X-2HDI-2SDO-RNO-S)
Product Type Isolating Switch Amplifier
Number of Channels 2
Input Type NAMUR sensor (DIN EN 60947-5-6) or switch contact
NAMUR Supply 8 V DC / 8 mA
Output Type Relay (1 NO contact per channel)
Nominal Switching Voltage 125 V AC / 110 V DC (safe area)
Continuous Current 0.5 A AC / 0.3 A DC
Supply Voltage 19.2 to 31.2 V DC
Power Consumption ≤ 1.9 W
Configuration FDT/DTM software
Connection Type Screw connection
Protection Degree IP20
Operating Humidity 0 to 95% (no condensation)
Dimensions (H x W x D) 117.2 mm x 22.5 mm x 113.6 mm
Weight 0.190 kg

Connections and Interfaces

Terminal Pin Function
Inputs (Hazardous Area) Channel 1 & Channel 2 NAMUR / Switch Contacts
Outputs (Safe Area) Channel 1 & Channel 2 Relay NO Contacts
Power Supply 24 V DC (+ / -)
Alarm Output Fault signaling relay contact

Installation Guidelines

  • Mounting: Mount vertically on a standard TS 35 DIN rail.
  • Wiring: Ensure strict physical separation between intrinsically safe (Ex i) input wiring and non-intrinsically safe output/power wiring. Maintain a minimum distance of 50 mm between the terminal groups.
  • Grounding: Connect the DIN rail to the local functional earth ground to ensure proper shielding and noise immunity.
  • Ventilation: Provide adequate clearance above and below the module to prevent heat buildup inside the control cabinet.

Compliance and Certifications

  • CE
  • ATEX
  • IECEx
  • UL Class I, Division 2 / Zone 2

What is the primary function of the Weidmuller 8965370000?

It is a 2-channel isolating switch amplifier designed to safely transmit digital signals (such as NAMUR sensors or mechanical contacts) from hazardous Ex zones to safe areas.

How is the ACT20X-2HDI-2SDO-RNO-S configured?

The module is configured using standard FDT/DTM software, allowing precise adjustment of input types, line fault detection, and output behavior.

What type of outputs does this module provide?

It features two normally open (NO) relay outputs, along with an integrated alarm relay for system status and fault signaling.

Does the 8965370000 support line fault detection?

Yes, it includes built-in line fault detection (LFD) to monitor input circuits for short circuits and wire breaks.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
เยอรมนี

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...