1 / 1

B&R X20CS1070 X20 Series CAN Bus Communication Module

B&R X20CS1070 X20 Series CAN Bus Communication Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20CS1070

  • Country of origin:Avusturya

  • Product Type: X20 Electronics Module Communication

  • Payment: T/T, Western Union

  • Weight: 4000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Adet
Tüm ayrıntıları görüntüle

Product Overview

The X20CS1070 (X20CS1070) is a high-performance communication electronics module within the B&R X20 System lineup, serving as a dedicated gateway for CAN bus integration. Engineered for deterministic data exchange in complex industrial networks, this module allows X20 PLC systems to interface seamlessly with CAN-based peripherals such as variable frequency drives (VFDs), specialized sensors, and third-party controllers. Supporting transfer rates up to 1 Mbit/s, the X20CS1070 is vital for high-speed motion control and real-time process monitoring. Its compact 12.5 mm design, combined with integrated diagnostic indicators and a software-switchable terminating resistor, ensures a streamlined installation process while maintaining the highest levels of network stability.

Network Architecture and Communication Logic

The X20CS1070 acts as a robust communication bridge, providing the physical and logical layer necessary for reliable CAN networking in harsh EMI environments.

  • High-Speed Throughput: Supports standard CAN transmission rates from low-speed long-distance runs up to a maximum of 1 Mbit/s for local high-speed synchronization.

  • Integrated Termination: Features an internal terminating resistor that can be activated via software, eliminating the need for external resistors at the end of the bus line.

  • Extended Network Reach: Capable of managing network segments with a maximum distance of 1000 m (at reduced bitrates), making it suitable for large-scale factory floor deployments.

  • Advanced Diagnostics: Four dedicated LEDs provide instant feedback on Data Transfer, Terminating Resistor status, Operating Status, and Module Status.

Technical Specifications

Feature Specification Details
Model X20CS1070
Brand B&R (Bernecker + Rainer)
Module Type Communication Electronics Module
Protocol CAN bus
ID Code 0x1FD1
Transfer Rate Max. 1 Mbit/s
Maximum Distance 1000 m
Terminating Resistor Integrated (Software-switchable)
Terminal Block Required: 12-pin X20TB12
Operating Temp 0 to +55 Celsius
Shipping Weight 4.0 kg

Technical FAQs

How do I activate the internal terminating resistor in the X20CS1070?

The terminating resistor is software-controlled within B&R Automation Studio. In the module's hardware configuration, you can toggle the resistor "ON" if the module is positioned at the physical end of the CAN network segment, ensuring signal integrity by preventing reflections.

What is the significance of the 0x1FD1 ID code?

The 0x1FD1 ID code is the unique electronic identifier for the X20CS1070. When the X20 system performs its power-on self-test (POST), the bus controller verifies this ID to ensure the physical hardware matches the software project configuration, preventing communication mismatches.

Can I use the X20CS1070 for CANopen applications?

Yes. While the module manages the physical and data link layers of the CAN bus, higher-level protocols like CANopen are handled via the B&R software libraries. The X20CS1070 provides the deterministic hardware foundation required for robust CANopen master or slave functionality.


Field Engineering & Installation Guide

  • Wiring for Long Distances: For runs approaching the 1000 m limit, use high-quality twisted-pair cabling with a cross-section of at least 0.5 mm squared. Ensure the transfer rate is lowered in Automation Studio to match the physical cable length (e.g., 50 kbit/s for 1000 m).

  • Terminal Block Connection: This electronics module requires a 12-pin X20TB12 terminal block. Ensure that the shield of the CAN cable is connected to the functional ground (FE) at the terminal block to divert high-frequency interference.

  • Grounding Best Practices: To prevent ground loops across long CAN segments, ensure that the potential equalization between the different network nodes is addressed. The X20 system's internal bus isolation helps, but a common reference ground for the CAN transceiver is recommended.

Engineering Advantages

The X20CS1070 is designed for maximum uptime in mission-critical systems. The 4.0 kg shipping weight (reflecting the protective bulk packaging) underscores the industrial-grade nature of B&R's communication hardware. The module's ability to provide real-time status via LEDs—specifically the "Terminating Resistor" LED—allows for rapid visual audits of network topology without opening software diagnostics. Its wide operating temperature and IP20 protection ensure it thrives in the heat and vibration common to cabinet-mounted industrial automation.

 

Key Features:

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Gri Beyaz
Country of origin
Avusturya
Power source
DC Güç

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Recently Viewed Products

Technical knowledge

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robotik tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...

Geçmişe Dönüş: Erken Elektrik Motorları Yeraltı Madenciliğini Nasıl Değiştirdi?

Halatla çalışan DC kompresörlerden bataryalı maden arabalarına kadar, erken madencilik faaliyetleri endüstriyel elektrifikasyonda bir dönüm noktası oldu. Bu makale, elektrik motorlarının modern...

Factory I/O: Endüstriyel Otomasyon Eğitimi için Modern Bir PLC Simülasyon Aracı

Factory I/O, öğrenciler, mühendisler ve bakım ekipleri için sürükleyici 3D endüstriyel simülasyonlar sunarak PLC eğitimini dönüştürüyor. Platform, teori ile gerçek dünya otomasyon uygulamaları...

CMZ Servo Sürücüsünde Tek Eksenli Hareket Döngülerinin Programlanması

Bu eğitim, bir CMZ SBD servo sürücüsündeki dahili PLC işlevselliğinin, harici bir PLC olmadan homing mantığı, konum kontrolü ve döngüsel eksen hareketi dahil olmak üzere bağımsız hareket...

CMZ Servo Sürücülerle Tek Eksenli Hareket Kontrol Kurulumu

Bu eğitim, endüstriyel otomasyon ortamları için CMZ SBD sürücü kullanarak tek eksenli servo hareket sisteminin devreye alınmasını, donanım kurulumu, eksen ölçeklendirme, sıfırlama yapılandırması ve...