1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Beckhoff EL2596-0010 EtherCAT Terminal 1-Channel LED Output Module

Beckhoff EL2596-0010 EtherCAT Terminal 1-Channel LED Output Module

Stokta sadece 10 adet kaldı
  • Üretici: BECKHOFF

  • Ürün No.: EL2596-0010

  • Menşei ülke:Almanya

  • Ürün Türü: EtherCAT Terminals

  • Ödeme: T/T, Western Union

  • Ağırlık: 2000g

  • Boyutlar: 12 mm x 100 mm x 68 mm

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Providing direct current control and precise pulse timing for high-speed industrial vision systems, the Beckhoff EL2596-0010 is a highly specialized EtherCAT Terminal engineered for LED illumination control. This high-density module operates up to 48 V DC and delivers up to 3 A in pulsed mode, allowing direct synchronization with industrial cameras. By utilizing Distributed Clocks, the terminal achieves trigger and synchronization precision of less than 1 microsecond, making it ideal for fast-moving inspection lines. It supports multiple operating modes including constant voltage, constant current, and pulse-width modulation (PWM), alongside built-in trigger inputs and outputs to streamline camera-to-light interfacing without external controller lag.

Features

  • 1-Channel LED Output: Delivers flexible illumination control with continuous or high-intensity pulsed modes.
  • Integrated Synchronization: Built-in Distributed Clocks provide synchronization precision down to less than 1 microsecond.
  • Flexible Control Modes: Configurable via CoE (CoE - CAN over EtherCAT) for constant current, constant voltage, or high-frequency PWM operation.
  • Direct Camera Triggering: Features 1 electrically isolated trigger input (from camera) and 1 electrically isolated trigger output (to camera) to eliminate external delay stages.
  • Compact HD Housing: High-density 12 mm wide polycarbonate enclosure with integrated signal LEDs for channel state diagnostics.
  • Real-Time Diagnostics: Extensive diagnostic monitoring parameters available over EtherCAT, checking for voltage limits, open circuits, and overtemperature faults.

Applications

  • High-speed industrial machine vision systems
  • Automated optical inspection (AOI) units
  • Semiconductor manufacturing wafer scanning
  • RGB and common-anode LED lighting control
  • Synchronized multi-angle camera inspection stations

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model Number EL2596-0010
Output Type 1-channel LED output
Connection Technology 2-wire
Input Voltage Range 48 V DC (-15% / +20%)
Output Voltage Range 0 to (Input Voltage - 2 V)
Max. Output Current (Continuous) 0 to 1.2 A
Max. Output Current (Pulsed Mode) 0 to 3 A (depending on output voltage and duty cycle)
Distributed Clocks (DC) Yes, precision less than 1 microsecond
Switching Times Typical TON: less than 1 us, TOFF: less than 1 us
Pulse Duration Range 25 microseconds to 10 seconds
Trigger Output (To Camera) 1 electrically isolated, max. 10 mA push-pull, 10 to 24 V DC
Trigger Input (From Camera) 1 electrically isolated, typ. 3 mA, 4 to 24 V DC
E-bus Current Consumption Typical 265 mA
Power Contact Current Load Max. 10 A
Electrical Isolation 500 V (E-bus / field potential)
Protection Rating IP20
Operating / Storage Temp 0 to +55 degC / -25 to +85 degC
Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Net Unit Weight 55 g
Shipping Weight (Calculated) 2.0 kg (including secure export packaging)

Wiring & Connection Terminals

Conductor Type Cross-Section (Metric) Cross-Section (AWG)
Solid Wire (s) 0.08 to 1.5 mm² AWG 28 to 16
Stranded Wire (st) 0.25 to 1.5 mm² AWG 22 to 16
Flexible with Ferrule (f) 0.14 to 0.75 mm² AWG 26 to 19
Stripping Length 8 to 9 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The EL2596-0010 operates within standard EtherCAT networks and requires a compatible Beckhoff Coupler (such as EK1100 or EK1200) or an Embedded PC. When migrating from legacy analog output cards or PWM modules used for light dimming (such as EL2502), the EL2596-0010 provides highly superior response times and dedicated hardware camera triggering lines, making external pulse generators redundant. Ensure your TwinCAT version is up to date (TwinCAT 3.1 or higher is recommended) to fully leverage the XML device description files for the CoE configurations.

Application Pitfalls & Engineering Notes

While the module can deliver up to 3 A in pulsed mode, engineers must tightly calculate the thermal profile and duty cycle. Exceeding the maximum allowed duty cycle at high currents can cause thermal shutdown faults. When configuring the LED output, verify if your illumination source requires constant current or constant voltage; choosing the incorrect mode in the CoE directory can over-drive and damage sensitive LED arrays. Additionally, when drawing full 10 A continuous currents across the power contacts, ensure appropriate ventilation inside the enclosure.

Commissioning & Wiring Tips

To prevent high-frequency EMI noise from interfering with the camera's triggering signals, always use shielded twisted-pair (STP) wiring for the trigger input and trigger output loops. Keep the cable length to the camera trigger under 10 meters if operating at maximum frequency. When wiring the solid or stranded conductors into the push-in High-Density terminal connections, utilize a dedicated flat-blade terminal screwdriver to depress the spring mechanism gently. This prevents damage to the internal clamp assembly.

Installation Guidelines

CRITICAL WARNING: Ensure that the entire control cabinet and all field power supplies feeding the EtherCAT terminal segment are fully de-energized before mounting, removing, or wiring the EL2596-0010. Hot-swapping modules or live-wiring the 48 V DC input can lead to destructive electrical arcing, irreparable module damage, or immediate hardware failure.
1

Mount the terminal onto a 35 mm DIN rail conforming to EN 60715. Align the side-by-side slot-and-key connection and push firmly until the locking mechanism clicks securely.

2

Establish the E-bus connections by sliding the module horizontally against the adjacent EtherCAT terminal until the contacts touch fully.

3

Connect the 48 V DC field power supply to the terminal inputs, taking care to respect nominal voltage tolerances (-15% / +20%).

4

Wire the LED output lines and camera trigger lines using correct stripping lengths (8 to 9 mm) and shield terminations to prevent electromagnetic coupling.

Loading product navigation…

What is the primary difference between pulsed and continuous output current for this terminal?

In continuous mode, the terminal delivers up to 1.2 A. In pulsed mode, it can supply up to 3 A. However, pulsed mode is heavily dependent on the output voltage and duty cycle to prevent thermal damage to the module.

How do you select between constant current and constant voltage operating modes?

The modes are configured programmatically in TwinCAT via the CoE (CAN over EtherCAT) online directory. Ensure you set the correct mode matching your LED specifications before enabling the channel.

Does the EL2596-0010 require external power contacts?

The terminal utilizes the external 48 V DC power supply fed directly into the terminal points to power the LED channel. The internal E-bus connections only power the communication logic of the module.

What is the role of Distributed Clocks (DC) in this LED output module?

Distributed Clocks synchronize the trigger output and pulse generation with other network nodes (such as camera inputs or motion axes) with sub-microsecond precision, eliminating jitter in high-speed inspection lines.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Almanya

Son Görüntülenen Ürünler

Teknik bilgi

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...

Geçmişe Dönüş: Erken Elektrikli Motorlar Yeraltı Madenciliğini Nasıl Değiştirdi

Halatla çalışan DC kompresörlerden bataryalı maden arabalarına kadar, erken madencilik faaliyetleri endüstriyel elektrifikasyonda bir dönüm noktası oldu. Bu makale, elektrik motorlarının modern...