1 -ın, -in, -un, -ün (bağlama göre değişir) 1

BECKHOFF EP4378-1022 EtherCAT Box I/O Module

BECKHOFF EP4378-1022 EtherCAT Box I/O Module

Stokta sadece 10 adet kaldı
  • Üretici: BECKHOFF

  • Ürün No.: EP4378-1022

  • Menşei ülke:Almanya

  • Ürün Türü: EtherCAT Boxes

  • Ödeme: T/T, Western Union

  • Ağırlık: 250g

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Designed for decentralized automation tasks, the EP4378-1022 accommodates high-density digital and analog signals within a ruggedized, field-mountable housing. This Beckhoff EtherCAT Box serves as a versatile combination module, integrating 8 digital inputs, 8 digital outputs, 4 analog inputs, and 4 analog outputs. By providing comprehensive I/O capabilities directly on the machine, it eliminates the requirement for protective control cabinets and complex terminal boxes.

The analog channels on the module are highly adaptable, supporting both current and voltage modes (-10/0 to +10 V or -20/0/4 to +20 mA) customizable per individual channel at a precise 16-bit resolution. Built-in M12 connector interfaces ensure sealed, vibration-resistant connections under demanding industrial conditions, drastically reducing field wiring complexity and installation time.

Features

  • Combination module with 8 digital inputs/outputs and 4 analog inputs/outputs.
  • Parameterizable analog signals (voltage or current) configurable per channel.
  • High 16-bit resolution for precise analog-to-digital and digital-to-analog signal processing.
  • Direct field installation with IP65, IP66, and IP67 ingress protection ratings.
  • Dual M8 shielded, screw-type socket interfaces for high-speed EtherCAT communication.
  • Integrated actuator supply derived from the auxiliary voltage UP (short-circuit proof).
  • Electrical isolation of 500 V to isolate external field potentials from the EtherCAT network.

Applications

  • Decentralized field instrumentation and sensor arrays in assembly plants.
  • Machine tool control and localized factory automation networks.
  • Process control systems in wet, dusty, or demanding industrial environments.
  • Material handling systems requiring high-density localized I/O routing.

Technical Specifications

ManufacturerPart Number / ModelProtocolBus InterfaceNumber of Digital I/ONumber of Analog I/OI/O ConnectionsSignal TypeResolutionConversion TimeMeasurement UncertaintyOutput LoadInput Internal ResistanceActuator SupplyCurrent Consumption from USPower Supply ConnectionElectrical IsolationWeightOperating TemperatureStorage TemperatureProtection RatingVibration/Shock ResistanceEMC Immunity/Emission
BECKHOFF
EP4378-1022
EtherCAT
2 x M8 socket, shielded, screw type
8 x inputs, 8 x outputs
4 x inputs, 4 x outputs
M12 x 1, 5-pin, a-coded
-10/0 to +10 V | -20/0/4 to +20 mA (parameterizable per channel)
16 bit
Input: ~100 us, Output: ~40 us
Input: < 0.3%, Output: < 0.1% (relative to full scale value)
Voltage mode: > 5 kOhm | Current mode: < 350 Ohm
Voltage mode: > 200 kOhm | Current mode: typ. 85 Ohm + diode voltage
From auxiliary voltage UP, max. 0.5 A (total short-circuit proof)
120 mA
Feed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin
500 V
approx. 250 g
-25 to +60 degC
-40 to +85 degC
IP65/66/67 (conforms to EN 60529)
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Connector Type Interface Style Function Description
EtherCAT Bus 2 x M8 socket, shielded, screw type Inbound and outbound industrial Ethernet communications
I/O Channels M12 x 1, 5-pin, a-coded Direct connection for analog and digital field sensors/actuators
Power Feed 1 x M8 male socket, 4-pin Input power supply feed (US and UP lines)
Power Downstream 1 x M8 female socket, 4-pin Loop-through supply connection for downstream EtherCAT modules

Installation Guidelines

  • Mount securely to an industrial machine frame or mounting plate using the integrated screw holes. Installation is permitted in variable positions.
  • Ensure all mating M8 and M12 connectors are tightened to the recommended torque specifications to maintain the IP65/66/67 physical seal.
  • Route signal and EtherCAT cables separately from high-voltage AC power lines to prevent electromagnetic interference.
  • Ground the device using the designated connection point to safeguard communication integrity in electrically noisy environments.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What is the physical protection rating of the Beckhoff EP4378-1022?

The EP4378-1022 features an IP65/66/67 protection rating (conforming to EN 60529), making it completely dust-tight and resistant to water jets and temporary immersion, enabling direct installation in harsh field environments without an enclosure.

Can the analog channels be individually configured for different signal types?

Yes, each of the 4 analog inputs and 4 analog outputs is parameterizable individually for either voltage (-10/0 to +10 V) or current (-20/0/4 to +20 mA) depending on your field device requirements.

What is the resolution and conversion speed for the analog channels?

The module operates with a high 16-bit resolution. The signal conversion time is approximately 100 microseconds for inputs and 40 microseconds for outputs.

How is power distributed to downstream EtherCAT Box modules?

The module features a 4-pin M8 male power inlet for the feed, and a 4-pin M8 female socket for downstream connection, allowing you to daisy-chain the power supply (US/UP) to adjacent modules.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Almanya

Son Görüntülenen Ürünler

Teknik bilgi

OpenPLC Platformu Kullanarak Matematiksel İşlemler

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

FBD PLC Programlama ile Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robotik tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...

Geçmişe Dönüş: Erken Elektrik Motorları Yeraltı Madenciliğini Nasıl Değiştirdi?

Halatla çalışan DC kompresörlerden bataryalı maden arabalarına kadar, erken madencilik faaliyetleri endüstriyel elektrifikasyonda bir dönüm noktası oldu. Bu makale, elektrik motorlarının modern...