1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Beckhoff IP3202-B200 Fieldbus Box Lightbus RTD Input Module

Beckhoff IP3202-B200 Fieldbus Box Lightbus RTD Input Module

Stokta sadece 10 adet kaldı
  • Üretici: BECKHOFF

  • Ürün No.: IP3202-B200

  • Menşei ülke:Almanya

  • Ürün Türü: Fieldbus Modules

  • Ödeme: T/T, Western Union

  • Ağırlık: 500g

  • Boyutlar: 180 mm x 110 mm x 60 mm

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Engineered for decentralized temperature acquisition in demanding industrial environments, the Beckhoff IP3202-B200 fieldbus box delivers precise RTD sensor processing directly at the machine level without requiring a protective control cabinet. This module integrates high-performance analog-to-digital conversion with the noise-immune Lightbus fiber-optic communication system, allowing reliable long-distance signal transmission in high-interference settings. The physical enclosure is built to withstand extreme mechanical stress, moisture, and dust, providing direct-to-machine mountability for minimized field-wiring loops.

Features

  • Lightbus Interface: Employs dual optical fiber connections operating at 2.5 Mbaud, providing absolute electrical isolation and immunity against electromagnetic interference.
  • Direct RTD Acquisition: Optimized for standard RTD and Pt100 temperature sensors without requiring external signal transmitters.
  • Robust IP67 Enclosure: Designed for direct field mounting in wet, dusty, or high-vibration environments, complying with IP65, IP66, and IP67 protection standards.
  • Efficient Power Daisy-Chaining: Dual M8 connectors (male feed and female downstream) enable direct distribution of control voltages across multiple fieldbus boxes.
  • Flexible Configuration: Accessible parameters and calibration settings manageable via Beckhoff KS2000 software or directly through controller register structures.

Applications

  • Decentralized temperature sensing in washdown areas, food processing, and chemical production.
  • Remote monitoring on highly articulated mechanical systems and robotic assemblies.
  • Noise-sensitive installations where traditional copper fieldbus lines suffer from EMI/RFI issues.
  • Distributed HVAC and environmental control loops in large industrial facilities.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation
Model / Part Number IP3202-B200
Fieldbus System Lightbus (Fiber-Optic Ring)
Data Transfer Rate 2.5 Mbaud
Bus Connection 2 x fiber-optic socket for ZS1020-0010 plug
Control Voltage 24 V DC (-15% / +20%)
Power Connections Feed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)
Electrical Isolation Control voltage to fieldbus: Yes
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Approvals CE, UL
Country of Origin Germany
Weight (Net) 250 g
Shipping Weight (Calculated) 0.55 kg
Package Dimensions (Calculated) 180 mm x 110 mm x 60 mm

Connections and Interfaces

M8 Pin Location Function / Circuit Assignment
Pin 1 Feed: Control Voltage +24 V DC / Downstream: Control Voltage +24 V DC
Pin 2 Feed: Auxiliary/Load Voltage +24 V DC / Downstream: Auxiliary/Load Voltage +24 V DC
Pin 3 Feed: GND Control Voltage / Downstream: GND Control Voltage
Pin 4 Feed: GND Auxiliary/Load Voltage / Downstream: GND Auxiliary/Load Voltage

Empirical Engineering Insights

Alternative Models & Compatibility

The IP3202-B200 module is designed specifically for Beckhoff Lightbus architectures. If migrating or integrating with newer control platforms, keep in mind that Lightbus requires dedicated master PCI/PCIe cards (e.g., FC2001) or specific bus terminal controllers. For applications looking to migrate to EtherCAT without altering physical layouts, equivalent models from the EP series (such as the EP3202-0002) should be considered, though a change in network architecture and cabling from fiber-optic to industrial Ethernet is required.

Application Pitfalls & Engineering Notes

When working with fiber-optic connections in industrial rings, maintaining optical clean room standards is critical during physical installations. Avoid exceeding the minimum bending radius of the fiber-optic cabling (typically 30 mm for ZS1020 assemblies) to prevent signal loss or permanent physical degradation of the polymer fibers. Furthermore, any open or unused M8 or fiber-optic ports must be sealed using certified protective IP67 caps. Leaving these connections open in wet environments invites capillary moisture ingress, which can corrode internal components over time.

Commissioning & Wiring Tips

To configure analog channel operational characteristics, use the Beckhoff KS2000 software package connected via a serial configuration cable, or access the internal registry directly through the PLC startup parameters in TwinCAT. Ensure that the sensor cabling shields are terminated close to the fieldbus module's metal mounting ears to provide a low-impedance path to local earth ground, preventing high-frequency common-mode noise from corrupting delicate RTD measurements.

Installation Guidelines

CRITICAL WARNING: De-energize all power sources (both control and auxiliary load voltages) before performing any mounting, physical cleaning, or wiring modifications on the module. High-intensity light is used in optical networks; never look directly into the transmitter optical fiber or fiber-optic port while the system is powered.
1
Mount the Fieldbus Box securely onto a flat, vibration-resistant surface using two M4 bolts through the integrated mounting flanges.
2
Ensure the local machine frame is connected to a reliable system ground, and bond the module’s mounting surface appropriately.
3
Insert clean, undamaged fiber-optic cables (ZS1020-0010 connectors) into the optical interfaces until they click securely into place.
4
Connect the M8 power cables, ensuring they are tightened to the recommended torque specifications to maintain the IP67 integrity.
Loading product navigation…

Can I use the IP3202-B200 directly with an EtherCAT network?

No. The IP3202-B200 is built specifically for Beckhoff Lightbus fiber-optic communication. To interface this module with EtherCAT, you must use a Lightbus-to-EtherCAT gateway, or replace the box with an EtherCAT-native equivalent like the EP3202 series.

What is the recommended cable connector type for the fiber-optic ports?

The optical fiber connections are designed to be mated with Beckhoff ZS1020-0010 connectors, which provide the exact physical mechanical lock needed to maintain reliable communication.

How are analog inputs on the IP3202-B200 calibrated?

Calibration data, filter frequencies, and sensor types can be adjusted using Beckhoff KS2000 configuration software or by configuring register settings directly through the TwinCAT PLC environment.

Is external power needed for both control and auxiliary connections on the M8 ports?

Control voltage (Pin 1 and Pin 3) is required to power the internal electronics and Lightbus communication. The auxiliary load voltage (Pin 2 and Pin 4) is routed through the downstream port to supply adjacent modules but is not consumed internally by the IP3202 unless specific sensor configurations demand isolated auxiliary loop supply.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Almanya

Son Görüntülenen Ürünler

Teknik bilgi

Akışkan Güç Sistemlerinin Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Pratik Bir Endüstriyel Otomasyon Rehberi

Bu makale, SMC’nin e-Actuator serisi gibi entegre elektrikli aktüatörlerin, geleneksel pnömatik ve hidrolik sistemlerin yerini alarak endüstriyel hareket kontrolünü nasıl dönüştürdüğünü...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...