1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Beckhoff IP4112-B400 Fieldbus Box Module

Beckhoff IP4112-B400 Fieldbus Box Module

Stokta sadece 10 adet kaldı
  • Üretici: BECKHOFF

  • Ürün No.: IP4112-B400

  • Menşei ülke:Almanya

  • Ürün Türü: Fieldbus Box Modules

  • Ödeme: T/T, Western Union

  • Ağırlık: 500g

  • Boyutlar: 160 mm x 120 mm x 60 mm

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Designed for direct machine-mounting in demanding industrial environments, the Beckhoff IP4112-B400 establishes a ruggedized Interbus fieldbus interface without requiring an additional protective enclosure. By integrating control and processing mechanisms directly on-site, this module facilitates robust IP65/66/67-rated distributed I/O operation. It features standard M23 connection nodes for seamless network handshaking and is fully configurable using the specialized KS2000 configuration software environment.

Features

  • High-integrity Interbus network communication capabilities.
  • Robust IP65, IP66, and IP67 dust and liquid ingress protection.
  • Direct-to-machine installation footprint, eliminating terminal box requirements.
  • Dual M8 power interface configurations supporting simplified downstream daisy-chaining.
  • Full configuration integration within the Beckhoff KS2000 environment.
  • Exceptional vibration and shock resistance complying with European industrial standards.

Applications

  • Automotive assembly lines utilizing legacy and modern Interbus networks.
  • Material handling, logistics, and multi-zone conveyor systems.
  • Processing plants requiring decentralized I/O distribution in high-moisture or dusty zones.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Beckhoff Automation
Model Number IP4112-B400
Product Type Fieldbus Box
Bus Interface 1 x M23 female 9-pin, 1 x M23 male 9-pin (Interbus)
Control Voltage Supply 24 V DC (20 to 29 V DC)
Current Consumption (Box Supply) 85 mA + sensor load (max. 0.5 A)
Power Feed Connection 1 x M8 male socket, 4-pin
Power Downstream Connection 1 x M8 female socket, 4-pin
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Country of Origin Germany
Shipping Weight (Calculated) 0.55 kg
Package Dimensions (Calculated) 160 mm x 120 mm x 60 mm

Connections and Interfaces

M8 Power Connector Pin Function Assignment
Pin 1 Feed Control Voltage, +24 V DC
Pin 2 Feed Load Voltage (according to I/O configuration)
Pin 3 GND Control Voltage
Pin 4 GND Load Voltage

Empirical Engineering Insights

Alternative Models & Compatibility

The "B400" suffix designates native integration into Interbus topologies via M23 connectors. For migration paths to modern networks such as EtherCAT or PROFINET, alternative Fieldbus Box suffixes (e.g., "-B110" or "-B310") should be sourced. If replacing older generation modules, ensure that the existing Master configuration file (GSD or device description database) matches the legacy revision of this specific firmware sequence.

Application Pitfalls & Engineering Notes

A common point of failure in distributed setups is exceeding the total physical power distribution thresholds. When daisy-chaining modules via the downstream M8 connectors, ensure the total current consumption of sensor networks and auxiliary controls does not exceed the absolute limit of 0.5 A. Excessive current draw will trigger localized power rail dips and communication drops.

Commissioning & Wiring Tips

To maintain full IP67 ingress ratings in harsh operating conditions, unused M8 or M23 ports must be sealed with official protective threaded metal caps. Standard plastic transport plugs do not prevent liquid ingress over time. When utilizing KS2000 for diagnostics, ensure you use the proper isolated serial interface adapter to prevent ground loops between the fieldbus nodes and your PC hardware.

Installation Guidelines

CRITICAL WARNING:

Always isolate the 24 V DC supply lines before starting any assembly or maintenance operations. Connecting or disconnecting active cables under load can lead to diagnostic data corruption, arc flashes, or localized transceiver hardware failure.

1

Mount the Fieldbus Box on a flat, vibration-free surface utilizing standard M4 screws. Torque the mounting hardware to 1.2 Nm.

2

Establish the Interbus incoming and outgoing physical lines using high-shielded M23 9-pin industrial cables.

3

Connect the 24 V DC power distribution via the 4-pin M8 male connector. Securely hand-tighten all knurled collars to seat the internal O-ring seal.

Loading product navigation…

What is the primary fieldbus protocol supported by the IP4112-B400?

The IP4112-B400 is specifically designed for Interbus networks, utilizing standard 9-pin M23 connectors for network incoming and outgoing signals.

Can this module be mounted directly in washdown zones?

Yes, with IP65, IP66, and IP67 ratings, it is dust-tight and resistant to high-pressure water jets and short periods of immersion, provided all unused ports are capped.

What software is required to configure the unit?

The module is configured using the Beckhoff KS2000 software suite, connected via standard diagnostics channels.

How is power supplied and distributed to downstream devices?

Power is fed through an M8 4-pin male connector and can be daisy-chained to subsequent modules via the downstream M8 female connector, up to a maximum load of 0.5 A.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Almanya

Son Görüntülenen Ürünler

Teknik bilgi

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...

Geçmişe Dönüş: Erken Elektrikli Motorlar Yeraltı Madenciliğini Nasıl Değiştirdi

Halatla çalışan DC kompresörlerden bataryalı maden arabalarına kadar, erken madencilik faaliyetleri endüstriyel elektrifikasyonda bir dönüm noktası oldu. Bu makale, elektrik motorlarının modern...