1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Bently Nevada 330878-90-CN 3300 XL 50 mm Proximitor Sensor

Bently Nevada 330878-90-CN 3300 XL 50 mm Proximitor Sensor

Stokta sadece 7 adet kaldı
  • Üretici: Bently Nevada

  • Ürün No.: 330878-90-CN

  • Menşei ülke:Amerika Birleşik Devletleri

  • Ürün Türü: Proximitor Sensors

  • Ödeme: T/T, Western Union

  • Ağırlık: 320g

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Conditioning dynamic eddy current signals for high-reliability machinery diagnostics, the Bently Nevada 330878-90-CN operates as a key component of the 3300 XL 50 mm Proximitor Sensor system. This unit converts the radio frequency (RF) signal generated by the proximity probe into a proportional voltage output, enabling precise measurements of shaft displacement, vibration, and position in heavy rotating machinery. The specific -90-CN configuration designates a 9.0-meter system length with panel-mounting capability and regional-specific safety certifications.

Features

  • Optimized for the high-aperture fields of 50 mm proximity probes.
  • 9.0-meter (29.5 feet) total system length calibration matches probe and extension cable impedance.
  • Rugged panel-mount design for secure installation within industrial junction boxes or instrument enclosures.
  • Corrosion-resistant A380 cast aluminum housing provides superior durability in harsh environments.
  • CN agency approval designation for country-specific regulatory compliance.

Applications

  • Thrust and radial vibration monitoring on large utility-scale steam and gas turbines.
  • Shaft centerline tracking and displacement analysis in hydroelectric generators.
  • Mechanical protection loops for high-horsepower industrial compressors and process pumps.
  • Torsional and structural displacement monitoring in power generation and marine propulsion.

Technical Specifications Table

Parameter Specification Value
Manufacturer Bently Nevada (Baker Hughes)
Model Number 330878-90-CN
Sensor Series 3300 XL 50 mm
System Length 9.0 meters (29.5 feet)
Mounting Configuration Panel Mount
Housing Material A380 Aluminum
Operating Temperature -51 degC to +100 degC (-60 degF to +212 degF)
Storage Temperature -51 degC to +105 degC (-60 degF to +221 degF)
Agency Approvals CN (Country Specific Approvals)
Shipping Weight (Calculated) 3.0 kg (6.6 lbs)
Country of Origin United States

Connections and Interfaces

Terminal / Port Function / Circuit Assignment
Coaxial Jack Accepts RF cable connection from the 3300 XL 50 mm extension cable / probe assembly.
Terminal VT Power input supply (-24 Vdc nominal).
Terminal OUT Dynamic output voltage signal (proportional to target distance).
Terminal COM Common ground reference.

Alternative Models & Compatibility

The 330878-90-CN must only be paired with 3300 XL 50 mm proximity probes and equivalent 9.0-meter matching systems. It is not interchangeable with 8 mm or 11 mm Proximitor sensors, as the internal oscillators and linearization curves are explicitly tuned for the electromagnetic footprint of the large 50 mm probe head. Intermixing components across different millimeter-scale families will lead to severe calibration drift and false machine trip signals.

Application Pitfalls & Engineering Notes

The 50 mm sensor system generates a broad electromagnetic field. Ensure that a clear, unobstructed side-clearance zone is maintained around the probe head to prevent parasitic targets (such as machine casing walls or internal brackets) from entering the detection field. Operating outside the rated temperature envelope (-51 degC to +100 degC) will degrade the sensor's temperature compensation circuitry, introducing measurement offset errors.

Commissioning & Wiring Tips

Always check the coaxial connector insulation prior to startup. The outer connector sleeve must be kept completely isolated from the machine ground; utilize Bently Nevada connector protectors or silicone heat-shrink tubing over the coaxial junctions. For signal integrity, route field wiring inside dedicated, grounded conduit, keeping it physically separated from high-voltage motor supply runs to minimize electromagnetic interference.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all external power sources before handling terminal block wiring. Failure to de-energize active monitoring systems prior to connection can introduce electrical transients that may cause damage to the monitoring rack input cards or trigger spurious turbine emergency trips.

1

Mount the Proximitor housing securely on the subpanel using the integrated mounting flanges. Ensure the mounting plate has a solid path to the structural instrument ground.

2

Connect the 9.0-meter extension cable coaxial plug to the sensor's coaxial jack. Hand-tighten the connector and ensure the mechanical locking mechanism is secure.

3

Install three-wire shielded instrument cabling to the VT, OUT, and COM screw terminals, maintaining proper torque to prevent loose terminations.

4

Ground the cable shield exclusively at the monitor rack/safety barrier end; do not connect the shield to ground at the Proximitor sensor terminal block to avoid ground loops.

Loading product navigation…

Can I use the 330878-90-CN with a standard 3300 XL 8 mm proximity probe?

No. The 330878-90-CN is designed and calibrated exclusively for the larger 3300 XL 50 mm probe system. Utilizing it with an 8 mm or 11 mm probe will cause incorrect scale factor output and inaccurate measurements.

What is the physical significance of the -90 configuration suffix?

The -90 suffix indicates a 9.0-meter (29.5 feet) calibrated system length with a panel-mount option. The internal impedance matching of the sensor requires a total physical cable length (probe plus extension) of exactly 9.0 meters.

What does the CN approval code mean on this Proximitor Sensor?

The CN option indicates country-specific agency approvals, typically signifying compliance with hazardous area standards and operational specifications required for localized plant deployment in China.

How do I ground the 330878-90-CN sensor housing?

The sensor should be panel-mounted to a metal subplate that is tied to local safety ground. However, the coaxial connection and cable shields must be kept isolated from the housing to prevent electrical ground loops that corrupt signal data.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Birleşik Devletleri

Son Görüntülenen Ürünler

Teknik bilgi

Akışkan Güç Sistemlerinin Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Pratik Bir Endüstriyel Otomasyon Rehberi

Bu makale, SMC’nin e-Actuator serisi gibi entegre elektrikli aktüatörlerin, geleneksel pnömatik ve hidrolik sistemlerin yerini alarak endüstriyel hareket kontrolünü nasıl dönüştürdüğünü...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...