1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Bently Nevada 74712-01-10-02-00 74712 High-temperature Two-wire Transducer

Bently Nevada 74712-01-10-02-00 74712 High-temperature Two-wire Transducer

Stokta sadece 7 adet kaldı
  • Üretici: Bently Nevada

  • Ürün No.: 74712-01-10-02-00

  • Menşei ülke:Amerika Birleşik Devletleri

  • Ürün Türü: High-temperature Velocity Transducers

  • Ödeme: T/T, Western Union

  • Ağırlık: 320g

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Designed for demanding high-temperature vibration monitoring environments, the Bently Nevada 74712-01-10-02-00 industrial velocity transducer provides critical machine casing measurements. This self-generating, two-wire sensor is specifically designed to measure structural velocity on gas turbines, steam turbines, or other high-temperature rotating machinery. Operating on an electrodynamic moving-coil design, the Bently Nevada 74712-01-10-02-00 provides a voltage output directly proportional to the vibration velocity, requiring no external power supply for signal generation.

Key Features

  • Self-Generating Design: Requires no external excitation power to generate the velocity voltage signal.
  • High Temperature Limit: Rated for sustained operation from -29 degC to +204 degC (-20 degF to +400 degF).
  • Optimized Mounting Angle: Configuration code 01 permits vertical mounting (0 +/-2.5 degrees) with a 4.5 Hz (270 cpm) minimum operating frequency.
  • Robust Connection: Top-mount connector housing protects signal wires from harsh environment exposure.
  • Secure Mounting Base: Features a circular M10X1 threaded connection base to ensure solid mechanical contact.

Industrial Applications

  • Heavy industrial gas turbines and steam turbine casings.
  • High-temperature power generation rotating assets.
  • Process pumps, compressors, and exhaust fans in petro-chemical plants.
  • Draft fans and machinery operating in extreme thermal zones.

Option Selection Decoding

Option Code Parameter Description Selected Value
01 Mounting Angle & Min Operating Frequency 0 +/-2.5 degrees, 4.5 Hz (270 cpm)
10 Mounting Base Circular M10X1 Thread
02 Connector Orientation Top Mount
00 Agency Approval No Approvals Standard

Technical Specifications

Specification Value / Detail
Manufacturer Bently Nevada
Model Number 74712-01-10-02-00
Transducer Type Electrodynamic Moving-Coil Velocity Transducer
Operating Temperature Range -29 degC to +204 degC (-20 degF to +400 degF)
Frequency Response Minimum 4.5 Hz (270 cpm)
Mounting Configuration Vertical (0 +/-2.5 degrees)
Physical Height 102 mm (4.0 in) typical
Physical Diameter 41 mm (1.6 in) typical
Net Transducer Weight 0.48 kg (1.06 lbs)
Shipping Weight (Calculated) 2.0 kg (4.4 lbs)
Country of Origin United States (U.S.A.)

Empirical Engineering Insights

Alternative Models & Compatibility

The 74712 velocity transducer series serves as a specialized, self-generating alternative to standard Piezoelectric Velocity Transducers (PVTs) in superheated environments where active electronics would fail. Ensure your monitor channel cards (such as the Bently Nevada 3500/42M) are explicitly configured to accept moving-coil (seismic) sensors. Attempting to run this on a standard accelerometer or IEPE channel configuration will produce signal clipping or no-reading errors.

Application Pitfalls & Engineering Notes

Never exceed the maximum structural temperature of 204 degC. Even though the body is designed for high temperatures, the interconnecting cabling must be insulated with FEP or glass braid. Avoid routing signal cabling along steam piping or unprotected thermal bridges without proper standoff brackets. Because this is a moving-coil sensor, physical drop damage can misalign the internal suspension springs, causing permanent sensitivity loss or signal distortion.

Commissioning & Wiring Tips

Always verify that the mounting surface is machined flat to at least 0.02 mm (0.001 inches) and free of rust or slag. Tighten the sensor to the specified torque. Avoid over-torqueing, which can warp the base and degrade the transducer frequency response. Ensure the shielding drain wire is only grounded at the system monitor panel; grounding both ends can induce ground loop noise into your turbine casing measurements.

Installation Guidelines

CRITICAL WARNING:

Ensure the machine is completely de-energized, depressurized, and cooled to ambient levels before performing installation. Direct contact with hot casing surfaces can cause severe personal injury. De-energize all power lines in the conduit route to prevent accidental electrical shock.

1
Inspect the machine casing mounting point. Ensure it matches the Circular M10X1 thread pattern and is drilled perpendicular to the casing surface to guarantee precise vertical alignment within the +/-2.5 degree specification limit.
2
Apply a light film of high-temperature mounting lubricant to the base threads and mate the transducer manually. Threading should be smooth. Torque the unit to the mechanical specification using a calibrated hand torque wrench.
3
Secure the high-temperature signal cable to the top mount connector. Ensure the cable is supported with adequate strain relief loops to prevent the weight of the conduit or cable bundle from stressing the connector housing.
Loading product navigation…

What is the primary function of the 74712 velocity transducer?

It measures casing vibration on high-temperature rotating machinery such as steam or gas turbines. It converts structural velocity into a proportional voltage signal without needing external power.

What mounting orientation does the -01 option code require?

The -01 option code specifies a vertical mounting orientation of 0 degrees with a strict tolerance of +/-2.5 degrees. This configuration supports a minimum operating frequency of 4.5 Hz (270 cpm).

Can this transducer be used in temperatures exceeding 204 degrees Celsius?

No, the physical limit for the transducer casing is 204 degC (400 degF). Exceeding this limit can permanently damage the internal suspension coil and degrade the calibration factor.

Does this transducer require loop power?

No. The moving-coil design is self-generating and creates its own voltage output relative to vibration velocity. Loop power is not required for signal generation.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Birleşik Devletleri

Son Görüntülenen Ürünler

Teknik bilgi

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...