Description

Engineered for high-integrity safety systems, the Honeywell FTA-T-08 is a 4-channel fail-safe digital output relay Field Termination Assembly (FTA). Designed to interface directly with safety-critical control modules such as the 10201/2/1, this unit provides robust galvanic isolation and contact multiplication for critical process shutdown and safety interlock loops. Each of the four channels features a redundant, diverse relay configuration utilizing devices from different manufacturers to mitigate common-cause failures and comply with rigorous functional safety requirements.

The FTA-T-08 incorporates an integrated 3.15 AT slow-acting fuse on each normally open (NO) field contact, protecting field-side wiring and devices from unexpected overcurrent conditions. Local status diagnostics are indicated through on-board LEDs, facilitating prompt field troubleshooting. Connection to the primary controller rack is accomplished using specialized SIC-C-02 cables, maintaining optimal signal integrity across the termination assembly.

Features

  • Four independent fail-safe digital output relay channels.
  • Redundant contact architecture featuring diverse relays from separate manufacturers to prevent common-mode failures.
  • Individual channel protection via 3.15 AT slow-acting fuses on the output contacts.
  • Integrated diagnostic LEDs for real-time channel status monitoring.
  • Silver alloy contacts designed for reliable and durable switching.
  • Direct integration compatibility with Honeywell 10201/2/1 modules using SIC-C-02 cable assemblies.

Applications

  • Emergency Shutdown Systems (ESD) in petrochemical and refinery environments.
  • Burner Management Systems (BMS) in power utility plants.
  • Fire and Gas (F&G) mitigation control networks.
  • Critical safety interlock loops in chemical processing.

Technical Specifications

Manufacturer Honeywell
Part Number/Model FTA-T-08 (3410713)
Module Compatibility 10201/2/1
Number of Channels 4
Nominal Input Voltage 24 Vdc
Maximum Input Voltage 31 Vdc
Relay Cut-in Voltage 19 Vdc
Typical Input Current 50 mA at 24 Vdc
Maximum Output Current 3.15 A
Minimum Output Current 400 mA at 24 Vdc
Maximum Switched Voltage 250 Vac / 150 Vdc
Maximum Switched Load 1250 VA / 150 W
Maximum Switched Frequency 20 Hz
Contact Material Silver alloy
Fuse Rating 3.15 AT (slow-acting), 5 x 20 mm or 5 x 25 mm
Electrical Lifecycles 80,000 operations
Mechanical Lifecycles 5,000,000 operations
Operating Ambient Temperature -40 degC to +60 degC (-40 degF to +140 degF)
Shipping Weight 1.5 kg

Connections and Interfaces

Connection Interface Specification
Termination Type T10 terminal connection
FTA Connector 1 x 4F connector layout
System Interface Cable SIC-C-02
Signals per Cable 4/4 channels

Installation Guidelines

  • De-energize all power sources before handling, mounting, or wiring the Field Termination Assembly.
  • Mount the module securely on a standard DIN rail or enclosure backplate inside a dust-free, dry industrial cabinet.
  • Isolate and route the high-voltage relay wiring separately from low-voltage logic signal cables.
  • Confirm that the field load does not exceed the maximum rated capacity of the 3.15 AT internal fuses.
  • Maintain sufficient spacing between adjacent modules to ensure continuous convection cooling within the specified ambient temperature limits.

Compliance and Certifications

  • CE Compliant
  • TUV Safety Certified
  • UL Listed
Loading product navigation…

What is the primary function of the Honeywell FTA-T-08?

The FTA-T-08 is a 4-channel fail-safe digital output relay Field Termination Assembly (FTA) designed for isolation and high-integrity switching in safety shutdown and interlock applications.

What makes the relay configuration in this module safety-oriented?

Each channel is built with a diverse pair of redundant relays from different manufacturers to minimize the risk of common-cause failures.

What type of overcurrent protection is installed on the FTA-T-08?

Each output channel features an individual 3.15 AT slow-acting fuse, compatible with standard sizes of 5 x 20 mm or 5 x 25 mm.

What are the operating temperature limits for the FTA-T-08?

The assembly is rated for operations in ambient temperatures ranging from -40 degC to +60 degC (-40 degF to +140 degF).

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma (resmi tatiller hariç) işlenir ve teslim edilir.


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Birleşik Devletleri

Son Görüntülenen Ürünler

Teknik bilgi

FBD PLC Programlama ile Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robotik tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...

Geçmişe Dönüş: Erken Elektrik Motorları Yeraltı Madenciliğini Nasıl Değiştirdi?

Halatla çalışan DC kompresörlerden bataryalı maden arabalarına kadar, erken madencilik faaliyetleri endüstriyel elektrifikasyonda bir dönüm noktası oldu. Bu makale, elektrik motorlarının modern...

Factory I/O: Endüstriyel Otomasyon Eğitimi için Modern Bir PLC Simülasyon Aracı

Factory I/O, öğrenciler, mühendisler ve bakım ekipleri için sürükleyici 3D endüstriyel simülasyonlar sunarak PLC eğitimini dönüştürüyor. Platform, teori ile gerçek dünya otomasyon uygulamaları...