1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Mitsubishi Electric FR-A840-04810-2-60 FR-A800 Inverter

Mitsubishi Electric FR-A840-04810-2-60 FR-A800 Inverter

Stokta sadece 10 adet kaldı
  • Üretici: Mitsubishi Electric

  • Ürün No.: FR-A840-04810-2-60

  • Menşei ülke:Amerika Birleşik Devletleri

  • Ürün Türü: VFD Inverter Modules

  • Ödeme: T/T, Western Union

  • Ağırlık: 120000g

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Designed for heavy industrial applications requiring exceptional motor control torque and reliability, the Mitsubishi Electric FR-A840-04810-2-60 is a high-capacity variable frequency drive within the premium FR-A800 inverter family. This 400V class inverter delivers precise vector, sensorless, and V/f control for highly demanding automation loops. It is engineered with a Class 3C2 conformal board coating for superior resistance against chemical and gaseous environmental hazards, making it ideal for deployment in harsh industrial settings. It features multiple overload ratings, allowing optimization for Super Light Duty (SLD) configurations up to a rated current of 481 A.

Features

  • Real Sensorless Vector Control: Achieves high-torque and fast response times without requiring an encoder feedback interface.
  • Enhanced Environmental Protection: Conformal coating (3C2 classification) on all internal printed circuit boards protects sensitive electronics from moisture, dust, and corrosive industrial gases.
  • Multi-Rating Capability: Seamless adjustment between Super Light Duty (SLD), Light Duty (LD), Normal Duty (ND), and Heavy Duty (HD) output profiles.
  • Integrated Safety Protocols: Built-in dual-channel Safe Torque Off (STO) capability for compliance with global functional safety regulations.
  • Advanced Connectivity: Built-in USB diagnostic port and support for multiple industrial Ethernet and fieldbus communication options.

Applications

  • Municipal wastewater aeration compressors and high-volume water pump systems.
  • Industrial manufacturing extruders, mixers, and continuous-run process machinery.
  • Metal processing rolling mills, wire drawing lines, and heavy material handling cranes.
  • Mining ventilation fans, large belt conveyor drives, and bulk material stackers.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Identifier FR-A840-04810-2-60
Product Series FR-A800 Series
Voltage Class 400 V Class (Three-Phase 380 to 500 VAC, 50/60 Hz)
SLD Rated Inverter Current 481 A
Control Logic Variant CA Type (European layout standard)
Circuit Board Coating With (Conforms to IEC 60721-3-3 Class 3C2)
Plated Conductor Without
Enclosure Rating IP00 (Open Type)
Cooling Mechanism Forced Air Cooling
Actual Unit Weight 120.0 kg

Connections and Interfaces

Terminal Group Functional Assignment / Description
R/L1, S/L2, T/L3 Main three-phase AC power supply input connections.
U, V, W Three-phase AC variable frequency output terminals to the induction or PM motor.
P/+, N/- DC link common bus terminals for connecting external braking units or regeneration modules.
S1, S2, SC Safety circuit input connections for redundant dual-channel STO (Safe Torque Off) shutdown loops.

Alternative Models & Compatibility

The FR-A840-04810-2-60 can directly upgrade older generation FR-A740-04810 series units. Note that control terminal layouts differ slightly: the "-2-60" represents a standard European control terminal structure, which may require minor wiring layout adjustments compared to Japanese native models (-1-60). Parameter conversion can be fully completed using Mitsubishi's FR Configurator2 software, although complex multi-speed and custom PID parameters should be audited manually post-migration.

Application Pitfalls & Engineering Notes

Due to the unit’s substantial weight (120 kg) and heat dissipation requirements under high load conditions, vertical mounting inside a robust, well-ventilated enclosure is mandatory. When designing cabinet ventilation, ensure the cabinet can evacuate the heavy thermal load produced by the drive at its nominal 481 A current rating. Avoid placing other heat-generating equipment directly below the inverter intake vents.

Commissioning & Wiring Tips

To prevent electrical noise issues on sensitive analog feedback lines, use shielded twisted pair (STP) cabling for all control-circuit inputs and ensure the shield is grounded only at the drive end. If the Safe Torque Off (STO) terminals (S1, S2, and SC) are not wired to an external emergency safety relay, the pre-installed shorting link blocks must remain in place; otherwise, the inverter will display an "E.SAF" alarm and refuse to run.

Installation Guidelines

CRITICAL WARNING

Ensure that the main incoming AC power source is fully de-energized, locked, and tagged out before removing the terminal cover plate. Wait at least 20 minutes for internal high-voltage capacitors to bleed down. Verify zero voltage across terminals P/+ and N/- with a reliable voltmeter before commencing terminal wiring.

1

Mount the heavy IP00 chassis vertically onto a flat, non-combustible steel surface using the specified mounting bolts.

2

Verify grounding connections are correctly established back to the main factory earth PE busbar using the shortest possible cable paths.

3

Tighten main terminal block power connections (R/L1, S/L2, T/L3 and U, V, W) using a calibrated torque wrench to the exact torque specifications detailed in the OEM manual to prevent hot-spot connections.

Loading product navigation…

What does the -60 suffix represent on the FR-A840-04810-2-60 inverter?

The -60 suffix indicates that the control printed circuit boards have been treated with a protective conformal coating conforming to IEC 60721-3-3 Class 3C2 guidelines, and that it does not feature plated copper conductors.

What is the maximum rated current for this inverter under different duty profiles?

Under Super Light Duty (SLD), the rated output current is 481 A. When configured for more demanding duty cycles such as LD, ND, or HD, the current limits must be derated according to the OEM manual specs.

How do you bypass the Safe Torque Off (STO) function if not utilizing external safety devices?

If an external safety circuit is not connected, you must install physical shorting jumpers across terminals S1-SC and S2-SC to prevent the drive from generating a continuous E.SAF lockout condition.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Birleşik Devletleri

Son Görüntülenen Ürünler

Teknik bilgi

Akışkan Güç Sistemlerinin Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Pratik Bir Endüstriyel Otomasyon Rehberi

Bu makale, SMC’nin e-Actuator serisi gibi entegre elektrikli aktüatörlerin, geleneksel pnömatik ve hidrolik sistemlerin yerini alarak endüstriyel hareket kontrolünü nasıl dönüştürdüğünü...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...