1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Mitsubishi Electric FR-F840-03250-2-60 FR-F800 Series Inverter

Mitsubishi Electric FR-F840-03250-2-60 FR-F800 Series Inverter

Stokta sadece 10 adet kaldı
  • Üretici: Mitsubishi Electric

  • Ürün No.: FR-F840-03250-2-60

  • Menşei ülke:Amerika Birleşik Devletleri

  • Ürün Türü: Variable Frequency Drives (VFD)

  • Ödeme: T/T, Western Union

  • Ağırlık: 74000g

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Optimizing flow control in heavy-duty pump and fan installations, the Mitsubishi Electric FR-F840-03250-2-60 functions as a heavy-capacity variable frequency drive from the FR-F800 series. This industrial inverter is engineered specifically for fan, pump, and compressor control, delivering high-efficiency operation through intelligent energy-saving algorithms. Incorporating advanced excitation control, it continuously monitors load demand to optimize torque and reduce power consumption in real time.

Features

  • Advanced Optimum Excitation Control: Automatically balances motor magnetic flux to achieve high energy efficiency even under changing load conditions.
  • Dual Overload Rating: Supports Super Light Duty (SLD) and Light Duty (LD) operational configurations to match specific load profiles.
  • Multi-Pump Control: Built-in advanced PID and multi-pump control algorithms allow coordinated operation of multiple auxiliary pumps.
  • Integrated Safety Function: Features functional safety inputs compliant with SIL 2 / PL d safety standards.
  • Onboard PLC Functionality: Enables basic logic programming directly within the inverter, reducing the need for external mini-PLCs.

Applications

  • Water and Wastewater: Intake pumps, booster stations, and aeration blower systems.
  • HVAC Systems: Large-scale industrial air handling units (AHUs), cooling towers, and chillers.
  • Factory Automation: Dust collectors, exhaust fans, and municipal ventilation systems.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Number FR-F840-03250-2-60
Series Name FR-F800 Series
Input Voltage Range 3-Phase 380 to 500 VAC (50/60 Hz)
Rated Output Current (SLD) 325 A
Rated Output Current (LD) 290 A
Control Method V/f Control, Advanced Magnetic Flux Vector Control, Optimum Excitation Control
Enclosure Protection Rating IP00 (Open Type)
Operating Ambient Temperature -10 to +50 degC (non-freezing, LD rating up to +40 degC without derating)
Shipping Weight (Calculated) 74.0 kg

Connections and Interfaces

Terminal Group Function Assignment
R/L1, S/L2, T/L3 3-Phase AC main power input connections.
U, V, W 3-Phase AC motor power output connections.
P/+, PR, N/- DC link terminals for optional braking units or shared DC bus configurations.
Control Terminals Analog inputs (voltage/current), multi-function digital inputs, safety stop (S1/S2/SIC), and relay outputs.

Alternative Models & Compatibility

The unit acts as a direct modern replacement for the legacy FR-F740-03250 series. When replacing older F700 series models, parameter configuration files can be migrated using the FR Configurator2 software suite. Note that physical dimensions and mounting bolt patterns may differ slightly from the legacy series; ensure layout spacing in enclosed cabinets allows for the ventilation clearances required by the FR-F800 design.

Application Pitfalls & Engineering Notes

This large-capacity inverter exhibits significant thermal dissipation requirements during peak loads. Ensure your electrical enclosure has active ventilation capable of moving hot air away from the drive heat sinks, especially if operating continuously in ambient environments above 40 degC. For installations exceeding 1000 meters above sea level, apply a current derating factor of 1% per 100 meters up to a maximum altitude of 2500 meters.

Commissioning & Wiring Tips

Always ground the drive independently using a Class D grounding connection with a low impedance path. Ground currents generated by high-frequency PWM switching can interfere with sensitive near-field analog signals. It is highly recommended to run encoder, transducer, and control loops in separate, shielded conduits isolated from the main U/V/W motor output cables by at least 30 cm.

Installation Guidelines

CRITICAL WARNING: HIGH-VOLTAGE RISK

Before beginning any installation, maintenance, or terminal wiring work, completely disconnect the main power source. Wait at least 10 minutes for the internal DC bus capacitors to discharge safely. Verify that the charge indicator lamp on the front cover is completely off and measure the voltage across terminals P/+ and N/- to confirm it is below 30 VDC.

1
Mount the inverter vertically onto a flat, non-flammable vertical surface (such as a metal backplate) to guarantee optimal convective airflow across the rear-mounted heat sinks.
2
Connect structural grounds to the designated ground terminals. Securely connect the R/L1, S/L2, and T/L3 incoming power lines and the U, V, and W motor cables using the specified M8/M10 terminal bolt torque specs.
3
Wire the external safety inputs to the dual-channel S1/S2 safety terminals if emergency stop integration is required, ensuring the jumper is removed if using an external safety relay.
Loading product navigation…

What is the difference between Super Light Duty (SLD) and Light Duty (LD) ratings for this inverter?

The SLD rating supports continuous currents up to 325 A with 110 percent overload capacity for 60 seconds, ideal for low-torque fan and centrifugal pump loads. The LD rating supports up to 290 A with 120 percent overload capacity for 60 seconds, providing higher torque handling for general-purpose applications.

Can this drive run without an external 24 VDC control power supply?

Yes, the inverter can operate utilizing the internal power generated from the main AC input line. However, an external 24 VDC supply can be connected to the control terminal block to keep control circuits and communications active when main power is disconnected.

How do I address electromagnetic interference (EMI) issues affecting nearby analog sensors?

Ensure the motor cable is shielded with 360-degree grounding at both ends, separate signal wiring from power cables by a minimum of 30 cm, and utilize the built-in EMC filter by confirming the physical grounding jumper is correctly installed.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Birleşik Devletleri

Son Görüntülenen Ürünler

Teknik bilgi

Akışkan Güç Sistemlerinin Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Pratik Bir Endüstriyel Otomasyon Rehberi

Bu makale, SMC’nin e-Actuator serisi gibi entegre elektrikli aktüatörlerin, geleneksel pnömatik ve hidrolik sistemlerin yerini alarak endüstriyel hareket kontrolünü nasıl dönüştürdüğünü...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...