1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Mitsubishi Electric FR-F840-04320-2-60 FR-F800 Series Inverter

Mitsubishi Electric FR-F840-04320-2-60 FR-F800 Series Inverter

Stokta sadece 10 adet kaldı
  • Üretici: Mitsubishi Electric

  • Ürün No.: FR-F840-04320-2-60

  • Menşei ülke:Amerika Birleşik Devletleri

  • Ürün Türü: Variable Frequency Drives

  • Ödeme: T/T, Western Union

  • Ağırlık: 120000g

  • Boyutlar: 920 mm x 520 mm x 480 mm

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Operating as a high-capacity motor speed controller, the Mitsubishi Electric FR-F840-04320-2-60 is engineered specifically for variable torque load management in demanding industrial processes. This FR-F800 Series Inverter delivers precise control for heavy-duty pumps, fans, and blowers by optimizing electrical energy consumption based on real-time load demand. Engineered with dual-rating structures, the module supports both Super Light Duty (SLD) and Light Duty (LD) configurations to match specific system requirements, ensuring high operational efficiency while protecting mechanical components from start-up stress.

Features

  • Dual Load Ratings: Highly adaptable power stages supporting 432A under Super Light Duty (SLD) and 380A under Light Duty (LD) operations.
  • Advanced Optimum Excitation Control: Continually adjusts the excitation current to its ideal limit, achieving significant energy savings under light load conditions.
  • Integrated PLC Functionality: Supports localized programming and logic control via internal software structures, reducing dependency on external master controllers.
  • Multi-Pump Control: Built-in sequencing algorithms enable direct management of up to four pumps without requiring external option cards.
  • Comprehensive Safety & Security: Built-in STO (Safe Torque Off) safety functions prevent unexpected motor startups during system maintenance.

Applications

  • Municipal water treatment plants (aeration blowers, intake pumps, and booster stations).
  • Large-scale commercial HVAC installations (cooling towers, chillers, and supply/exhaust fans).
  • Industrial clean rooms and manufacturing ventilation networks.
  • De-watering operations in mineral extraction and mining sites.

Technical Specifications Table

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Number FR-F840-04320-2-60
Inverter Series FR-F800
Input Supply Voltage Three-phase 380V to 500V AC (50Hz / 60Hz)
Rated Current (SLD) 432 A
Rated Current (LD) 380 A
Applicable Motor Capacity (SLD) 220 kW
Applicable Motor Capacity (LD) 185 kW
Enclosure Rating IP00 (Open Type)
Cooling System Forced Air Cooling
Shipping Weight (Calculated) 120 kg
Package Dimensions (Calculated) 920 mm x 520 mm x 480 mm

Connections and Interfaces

Terminal Class Terminal Designation Functional Assignment
Main Power R/L1, S/L2, T/L3 Three-phase AC power input line connections
U, V, W Three-phase AC output connections directly to motor stator
Control Inputs STF / STR Forward Start / Reverse Start command terminals
RL, RM, RH Low, Medium, and High multi-speed selection inputs
SD Common terminal for digital control inputs (isolated)
PC 24V DC external power supply input/output terminal
Analog Output AM / CA Analog signal outputs for output frequency or current feedback

Empirical Engineering Insights

Alternative Models & Compatibility

When migrating to the FR-F840-04320-2-60 from legacy platforms like the FR-F740 series, control terminal locations and logic assignments remain highly compatible. However, verify parameter mappings since the FR-F800 series utilizes expanded parameter blocks. Dedicated parameter transfer software (FR Configurator2) must be used to map and scale analog inputs to ensure parity in speed-reference loops.

Application Pitfalls & Engineering Notes

Operating at a continuous output rating of 432A (SLD) produces substantial thermal dissipation. Unrestricted air volume exchange is required in the housing enclosure. Standard panel configurations must allow a minimum clearance of 150 mm above and below the chassis, and the cabinet exhaust rate must prevent the ambient air directly surrounding the heatsink from exceeding 40 degC to avoid automatic thermal current limiting.

Commissioning & Wiring Tips

To protect motor stator windings from reflective voltage wave phenomena, we strongly recommend installing an output dV/dt filter or sinus filter for any motor lead runs exceeding 30 meters. Ensure that the control signal cables use twisted-pair shielded wire and are run in separate conduits isolated from the high-power AC output cables (U, V, W) to mitigate electromagnetic coupling.

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE HAZARD

Ensure that the main incoming three-phase AC power lines are fully de-energized and locked out before removing the terminal covers. Allow at least 10 minutes after disconnecting supply power for internal DC link capacitors to fully discharge. Always measure the DC voltage across terminals P/+ and N/- to verify that the charge is below 45V DC before starting internal installation or wiring operations.

1
Mechanical Mount: Mount the unit vertically onto an unpainted, conductive metallic backplate within a secure, dust-free industrial cabinet. Secure all mounting bolts to structural cross-members to support the unit's 120 kg weight.
2
Ground Connection: Ground the inverter chassis directly to the main system PE (Protective Earth) busbar. Ensure the connection path has low resistance and uses a ground wire rated for high fault currents.
3
Power Terminals: Route and crimp appropriate ring terminals onto the input power and motor power lines. Torque all terminal bolts to OEM torque specification to prevent hot spots and resistance losses under load.
4
I/O Commissioning: Connect the control terminal blocks, verifying that the common line (SD) is completely isolated from the PE chassis path to preserve signal integrity and avoid ground loop noise.
Loading product navigation…

What is the physical difference between SLD and LD ratings on this inverter?

Super Light Duty (SLD) allows a continuous output current of 432A with an overload capacity of 110% for 60 seconds. Light Duty (LD) limits the continuous current to 380A but increases the permissible overload capacity to 120% for 60 seconds.

Can this variable frequency drive run a permanent magnet motor?

Yes. The FR-F800 series features firmware that supports tuning and sensorless vector control for both standard induction motors and permanent magnet (PM) synchronous motors.

How do I resolve an E.OHT fault on this specific model?

An E.OHT fault indicates an external thermal relay operation or heatsink overheat. Verify that the cooling fans are spinning, check for physical blockages on the heatsink fins, and confirm that parameter 180 through 189 settings for control input terminal assignment match your thermal sensor's wiring logic.

What communication protocols are natively supported on this unit?

It features standard RS-485 Modbus-RTU protocol interfaces. Optional communication modules can be inserted into the internal slots to expand support to CC-Link, Profibus-DP, EtherCAT, and DeviceNet protocols.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Birleşik Devletleri

Son Görüntülenen Ürünler

Teknik bilgi

Akışkan Güç Sistemlerinin Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Pratik Bir Endüstriyel Otomasyon Rehberi

Bu makale, SMC’nin e-Actuator serisi gibi entegre elektrikli aktüatörlerin, geleneksel pnömatik ve hidrolik sistemlerin yerini alarak endüstriyel hareket kontrolünü nasıl dönüştürdüğünü...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...