Description

Integrating high-performance control and built-in industrial connectivity, the Mitsubishi Electric FX5U-64MT/ESS serves as a cornerstone processing unit within the MELSEC iQ-F compact PLC range. This controller delivers high-speed processing and robust capacity designed to handle complex automation sequences. Equipped with 32 digital inputs (24 V DC, sink/source) and 32 digital outputs (transistor, source), it provides an exceptional physical I/O density within a compact footprint. Users benefit from embedded Ethernet, RS-485 serial communication, and integrated analog I/O, minimizing the necessity for auxiliary expansion modules in mid-scale industrial systems.

Features

  • High-Speed Execution: Processing speeds of 34 ns for basic instructions ensure responsive system execution.
  • Embedded Ethernet Port: Supports CC-Link IE Field Basic, Modbus/TCP, and direct socket communications.
  • Built-In RS-485 Port: Allows seamless connection to up to 16 Mitsubishi inverters or Modbus/RTU devices.
  • Integrated Analog I/O: Built-in 2-channel analog input (0 to 10 V DC) and 1-channel analog output (0 to 10 V DC).
  • Hardware-Based Positioning: Features 4-axis pulse output (up to 200 kpps) for precise motion control applications.
  • SD Card Slot: Supports standard SD/SDHC cards for program backup, data logging, and easy firmware updates.

Applications

  • Multi-axis pick-and-place systems and packaging machinery.
  • Pumping station control, water filtration systems, and environmental chambers.
  • Automated material handling, conveying networks, and sorting systems.
  • Distributed HVAC control and facility monitoring systems.

Technical Specifications Table

Parameter Value / Specification
Manufacturer Mitsubishi Electric
Model Number FX5U-64MT/ESS
Product Series MELSEC iQ-F Series (FX5U)
Input Points 32 Points
Input Type 24 V DC (Sink / Source)
Output Points 32 Points
Output Type Transistor (Source)
Supply Voltage 100 to 240 V AC (+10% / -15%), 50/60 Hz
Power Consumption 45 W
Program Memory 64k Steps (Flash Memory)
Built-in Communication Ethernet (1 Port), RS-485 (1 Port)
Built-in Analog Inputs 2 Channels (0 to 10 V DC)
Built-in Analog Output 1 Channel (0 to 10 V DC)
Operating Temperature -20 to 55 degC (non-freezing)
Shipping Weight (Calculated) 1.00 kg
Package Dimensions (Calculated) 150 mm x 110 mm x 95 mm

Connections and Interfaces

Terminal Block Section Signal Assignment / Function
Power Terminals L (Line), N (Neutral), Protective Earth (Ground)
Digital Inputs (X0 - X37) S/S Terminal determines Sink or Source configuration. 24 V DC excitation.
Digital Outputs (Y0 - Y37) +V (External Power Supply Input), COM (Common negative path for source outputs)
Built-in Analog Input V1+, V2+, V- (Common ground for both channels)
Built-in Analog Output V+, V- (Voltage output channel)

Alternative Models & Compatibility

The FX5U-64MT/ESS acts as a modern upgrade path for legacy FX3U-64MT/ESS installations. While mounting footprints and programming software (transitioning from GX Works2 to GX Works3) differ, physical conversion brackets and the GX Works3 translation utility minimize migration effort. Ensure you verify output polarity: the /ESS model features source transistor outputs, unlike the /ES version which features sink transistor outputs.

Application Pitfalls & Engineering Notes

When switching inductive loads such as DC solenoid valves or relays using the transistor outputs, always install an external surge protection diode across the load. Overloading a transistor output terminal past 0.5 A can cause internal hardware damage. Note that the built-in analog inputs/outputs are non-isolated; using external signal isolators is highly recommended if cable runs extend outside the local control cabinet.

Commissioning & Wiring Tips

The built-in RS-485 communication line utilizes a 3-pin spring-clamp terminal. Always enable the terminating resistor (built-in, switch-selectable) at both physical ends of the RS-485 network segment to prevent signal reflections. Ensure that the SG (Signal Ground) line is properly linked across all nodes to stabilize common-mode voltages.

Installation Guidelines

CRITICAL WARNING: Completely isolate and de-energize the main AC power supply feeding the enclosure before performing any mounting, terminal wiring, or maintenance activities. Failure to do so exposes field staff to hazardous voltages and risk of severe shock.
1
Mount the CPU module on a standard 35 mm DIN rail or directly to the cabinet backplate using mounting screws, ensuring proper vertical orientation for optimal heat dissipation.
2
Connect the protective earth terminal directly to the main grounding bar inside the panel using a low-impedance conductor of at least 2.0 mm square.
3
Wire the AC power line (100 to 240 V AC) using recommended ferruled terminals, taking care to isolate signaling cables from high-power distribution lines.
Loading product navigation…

What is the difference between the FX5U-64MT/ES and the FX5U-64MT/ESS?

The FX5U-64MT/ES features sink transistor outputs (switching to ground/0V), while the FX5U-64MT/ESS features source transistor outputs (switching to +24V).

Which programming software is used for the FX5U-64MT/ESS?

The module requires GX Works3 software, which is part of the MELSOFT iQ Works suite.

Does this model support direct analog signal processing?

Yes. It features 2 integrated analog inputs (0-10 V DC) and 1 analog output (0-10 V DC) without requiring extra analog modules.

What is the maximum digital I/O expansion capability of this controller?

The CPU module supports up to 256 local digital I/O points, which can be expanded to 512 points when using CC-Link IE Field Basic network architecture.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma (resmi tatiller hariç) işlenir ve teslim edilir.


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Birleşik Devletleri

Son Görüntülenen Ürünler

Teknik bilgi

FBD PLC Programlama ile Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robotik tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...

Geçmişe Dönüş: Erken Elektrik Motorları Yeraltı Madenciliğini Nasıl Değiştirdi?

Halatla çalışan DC kompresörlerden bataryalı maden arabalarına kadar, erken madencilik faaliyetleri endüstriyel elektrifikasyonda bir dönüm noktası oldu. Bu makale, elektrik motorlarının modern...

Factory I/O: Endüstriyel Otomasyon Eğitimi için Modern Bir PLC Simülasyon Aracı

Factory I/O, öğrenciler, mühendisler ve bakım ekipleri için sürükleyici 3D endüstriyel simülasyonlar sunarak PLC eğitimini dönüştürüyor. Platform, teori ile gerçek dünya otomasyon uygulamaları...