1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Omron CJ1W-TC101 CJ Series Temperature Control Unit

Omron CJ1W-TC101 CJ Series Temperature Control Unit

Stokta sadece 4 adet kaldı
  • Üretici: Omron

  • Ürün No.: CJ1W-TC101

  • Menşei ülke:Japonya

  • Ürün Türü: Temperature Control Modules

  • Ödeme: T/T, Western Union

  • Ağırlık: 500g

  • Boyutlar: 15.0 cm x 12.0 cm x 5.0 cm

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Managing up to four high-precision closed-loop PID thermal processes, the Omron CJ1W-TC101 is a high-density, CJ Series Special I/O module engineered for direct interface with platinum resistance thermometers. This multi-loop module consolidates the functionality of four discrete temperature controllers into a single PLC slot, reducing panel footprint and wiring overhead. Equipped with a advanced 2-PID (two-degree-of-freedom) control algorithm, it minimizes overshoot while maintaining robust disturbance rejection. Its direct integration into the CJ-series backplane enables high-speed data access to process variables, set points, and manipulated variables without complex ladder communication, making it ideal for precision-critical heating and cooling applications.

Features

  • Four Closed-Loop Control Channels: Operates four independent loops simultaneously from a single, compact module.
  • Platinum Resistance Thermometer Inputs: Supports direct connections to Pt100 and JPt100 RTD sensors without external converters.
  • 2-PID Control Algorithm: Features advanced two-degree-of-freedom PID control to suppress thermal overshoot during startup and step changes.
  • NPN Open Collector Outputs: Equipped with open collector control outputs suitable for driving solid-state relays (SSRs) or digital indicators.
  • Auto-Tuning and Self-Tuning: Built-in optimization algorithms dynamically calculate proportional, integral, and derivative constants on-site.
  • Run/Stop Control: Allows individual or global loop enablement directly through PLC memory allocation tables.

Applications

  • Plastic Extrusion and Blow Molding: Precise multi-zone barrel temperature control to guarantee material viscosity consistency.
  • Packaging Equipment: High-speed thermal sealing bars requiring fast recovery times and minimal temperature droop.
  • Semiconductor Processing: Environmental chamber and wafer thermal conditioning systems demanding tight tolerances.
  • Food & Beverage Pasteurization: Reliable multi-point thermal monitoring and control adhering to food safety regulations.

Technical Specifications

Parameter Specification
Module Classification CJ-Series Special I/O Unit
Number of Control Loops 4 loops
Compatible Sensor Inputs Platinum Resistance Thermometers (Pt100, JPt100), 3-wire
Control Output Type NPN Open Collector (100 mA max at 24 VDC)
Sampling Period 500 ms (for all 4 loops combined)
Measurement Accuracy +/-0.3% of PV or +/-0.8 degC (whichever is larger) +/-1 digit max
Internal Current Consumption 5 VDC at 250 mA max (supplied via backplane)
External Power Supply 24 VDC +10%/-15%, 80 mA max
Isolation Method Photocoupler isolation between input terminals and PLC internal circuits
Manufacturer Omron Corporation
Country of Origin Japan
Shipping Weight (Calculated) 0.35 kg
Package Dimensions (Calculated) 15.0 cm x 12.0 cm x 5.0 cm

Connections and Interfaces

The CJ1W-TC101 utilizes an 18-point detachable terminal block. The standard mapping for the 4-channel platinum resistance thermometer inputs and NPN outputs is structured as follows:

Terminal Pin Assignment / Signal Function Terminal Pin Assignment / Signal Function
A1 Loop 1 RTD Input (A) B1 Loop 3 RTD Input (A)
A2 Loop 1 RTD Input (B) B2 Loop 3 RTD Input (B)
A3 Loop 1 RTD Input (B') B3 Loop 3 RTD Input (B')
A4 Loop 2 RTD Input (A) B4 Loop 4 RTD Input (A)
A5 Loop 2 RTD Input (B) B5 Loop 4 RTD Input (B)
A6 Loop 2 RTD Input (B') B6 Loop 4 RTD Input (B')
A7 Loop 1 NPN Output (+) B7 Loop 3 NPN Output (+)
A8 Loop 2 NPN Output (+) B8 Loop 4 NPN Output (+)
A9 Output Common (0V) B9 Output Common (0V)

Empirical Engineering Insights

Alternative Models & Compatibility

The CJ1W-TC101 is designed for 3-wire RTDs (Pt100 and JPt100). If your system utilizes thermocouples (such as Type K, J, or T), you must specify the CJ1W-TC001 thermocouple model instead. For loops requiring PNP (source) open collector outputs rather than NPN (sink) outputs, evaluate the CJ1W-TC102. These modules are hot-swappable only when the rack is entirely de-energized, and they maintain register mapping compatibility when moving from CJ1G/H CPUs to CJ2M/H processors.

Application Pitfalls & Engineering Notes

To prevent measurement error caused by unequal wire resistance, all three lead wires for each RTD must have identical lengths, gauge thicknesses, and physical routing. Avoid running RTD sensor lines in the same wire duct as 480 VAC motor power leads or high-speed VFD cables, as high-frequency electromagnetic noise will cause raw temperature readings to spike or drift, leading to false integral windups in the 2-PID loop.

Commissioning & Wiring Tips

When configuring the unit for the first time, use the Omron CX-Programmer IO Table setting interface to define input ranges and sensor types. Enabling the Auto-Tuning (AT) function requires that the process loop is in a stable, cold state. Running auto-tuning during a fluctuating process will result in calculated PID parameters that are too aggressive, causing severe hunting at the set point.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Always disconnect the main supply voltage to the PLC rack and all external 24 VDC auxiliary loops prior to mounting, removing, or wiring the terminal block of the module. Failure to de-energize equipment can cause permanent Damage to the internal analog inputs or result in unpredictable PLC CPU bus faults.

1

Mount the CJ1W-TC101 module onto the CJ-series backplane by securely engaging the bottom hook and pressing the top hook inward until it clicks into position.

2

Set the Unit Number rotary dials on the front panel of the module to assign memory allocation blocks in the CPU (each unit requires two unit numbers).

3

Connect the three RTD wires to the detachable terminal block as mapped. Connect the external 24 VDC auxiliary power supply to terminals A9 and B9.

4

Securely tighten all terminal block screws to a torque of 0.4 N-m to prevent loose contact faults under high-vibration conditions.

Loading product navigation…

Which RTD types does the CJ1W-TC101 support?

It supports standard 3-wire Pt100 and JPt100 platinum resistance thermometer inputs.

What type of control outputs are featured on this unit?

The module features 4 NPN open collector outputs rated for up to 100 mA at 24 VDC.

Is the CJ1W-TC101 compatible with CJ2H and CJ2M PLC systems?

Yes, it is fully compatible as a Special I/O Unit across both CJ1 and CJ2 CPU series, as well as NX/NJ series rack configurations.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Japonya

Son Görüntülenen Ürünler

Teknik bilgi

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...

Geçmişe Dönüş: Erken Elektrikli Motorlar Yeraltı Madenciliğini Nasıl Değiştirdi

Halatla çalışan DC kompresörlerden bataryalı maden arabalarına kadar, erken madencilik faaliyetleri endüstriyel elektrifikasyonda bir dönüm noktası oldu. Bu makale, elektrik motorlarının modern...