1 / 1

ProSoft PLX31-EIP-MBS PLX31 Series EtherNet/IP to Modbus Serial Gateway

ProSoft PLX31-EIP-MBS PLX31 Series EtherNet/IP to Modbus Serial Gateway

Stokta sadece 10 adet kaldı
  • Üretici: ProSoft

  • Ürün No.: PLX31-EIP-MBS

  • Menşei ülke:Amerika Birleşik Devletleri

  • Ürün Türü: Gateways

  • Ödeme: T/T, Western Union

  • Ağırlık: 2000g

  • Boyutlar: 13.67 cm x 5.05 cm x 11.13 cm

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Adet
Tüm ayrıntıları görüntüle

Description

Facilitating seamless data communication between EtherNet/IP-enabled control networks and Modbus serial networks, the ProSoft PLX31-EIP-MBS protocol converter operates as a standalone gateway. Designed to link Rockwell Automation PLCs, including ControlLogix and CompactLogix systems, to Modbus RTU/ASCII-compliant devices, this module acts as a bridge for legacy and modern system integration. It allows the integration of sensors, drives, and specialized instrumentation into high-level control architectures without requiring expensive network overhauls.

The gateway is engineered for harsh industrial environments, offering high electrical isolation on both the Ethernet and serial pathways to prevent damage from ground loops. Featuring a compact form factor for DIN rail installation, the gateway delivers reliable data routing with configurable read/write commands, mapping internal registry memory across protocols with minimum transmission latency.

Features

  • Dual-protocol mapping facilitates real-time data exchange between EtherNet/IP master/slave devices and Modbus RTU/ASCII networks.
  • Complete galvanic isolation on serial and Ethernet communication paths shields control equipment from electrical noise and voltage transients.
  • Integrated diagnostic LEDs provide real-time status indication for power, network connectivity, internal errors, and port traffic.
  • Flexible power input tolerances make the module suitable for diverse industrial power distribution standards.
  • Configuration is managed via user-friendly software utilities, allowing memory offset mapping and quick deployment.

Applications

  • Oil and gas production monitoring, connecting Modbus-based flow meters to EtherNet/IP RTU networks.
  • Water and wastewater plant automation for motor control center (MCC) integration.
  • Power generation and substation systems linking protective relays to central SCADA systems.
  • Factory automation environments standardizing fieldbus devices onto unified Ethernet backbones.

Technical Specifications

Manufacturer ProSoft Technology
Part Number / Model PLX31-EIP-MBS
Power Supply Input 24 VDC nominal (10 VDC to 36 VDC allowable)
Current Load 24 VDC nominal @ 300 mA (10 VDC to 36 VDC @ 610 mA maximum)
Operating Temperature -25 degC to 70 degC (-13 degF to 158 degF)
Storage Temperature -40 degC to 80 degC (-40 degF to 176 degF)
Relative Humidity 5% to 95% RH (non-condensing)
Vibration Protection IEC 60068-2-6; 5G @ 10 to 150 Hz
Ethernet Port 1x 10/100 Mbps RJ45 port (half/full duplex)
Ethernet Isolation 1500 Vrms for 60 seconds (per IEC 60950: 1991 section 5.3.2)
Serial Communication Port 1x RS-232/422/485 configurable port
Serial Port Isolation 2500 Vrms port signal isolation per UL 1577 (using RF-based isolation media)
LED Status Indicators Configuration (CFG), Error (ERR), Power (PWR), Hardware Fault (FLT), Network Status (NS), Module Status (MS), Serial RX/TX, Ethernet Link/Activity
Dimensions (H x W x D) 13.67 cm x 5.05 cm x 11.13 cm (approximate)
Shipping Weight 2.0 kg

Connections and Interfaces

Interface / Pin Function Description
RJ45 Port EtherNet/IP network communication and configuration port
Serial Port RS-232, RS-422, or RS-485 connection to Modbus slave or master field devices
V+ Terminal Positive DC Power input (10 to 36 VDC)
V- Terminal Negative DC Power return line
GND Terminal Chassis/Functional Ground reference

Installation Guidelines

  • Ensure the unit is mounted on a standard 35mm DIN rail within a dust-free and temperature-regulated control enclosure.
  • Always use shielded Ethernet (Category 5e or higher) and shielded twisted-pair serial cables to limit electromagnetic interference (EMI).
  • Connect the GND terminal directly to a clean, low-resistance functional earth ground bus bar.
  • Ensure there is adequate ventilation spacing of at least 25mm above and below the module during operation.
Loading product navigation…

What power input does the ProSoft PLX31-EIP-MBS require?

The gateway operates on a nominal 24 VDC power supply, but is compatible with a wider input range of 10 to 36 VDC.

Does the serial port on the PLX31-EIP-MBS feature isolation?

Yes, the serial port provides 2500 Vrms signal isolation utilizing RF modulation technology compliant with UL 1577 standards.

Can this gateway be used in extreme temperature environments?

Yes, the module is rated for an industrial operating temperature range of -25 degC to 70 degC (-13 degF to 158 degF).

Which Modbus protocols are supported by the serial port?

The gateway supports both Modbus RTU and Modbus ASCII protocols on its configurable RS-232/422/485 serial port.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma (resmi tatiller hariç) işlenir ve teslim edilir.


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Birleşik Devletleri

Son Görüntülenen Ürünler

Teknik bilgi

FBD PLC Programlama ile Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robotik tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...

Geçmişe Dönüş: Erken Elektrik Motorları Yeraltı Madenciliğini Nasıl Değiştirdi?

Halatla çalışan DC kompresörlerden bataryalı maden arabalarına kadar, erken madencilik faaliyetleri endüstriyel elektrifikasyonda bir dönüm noktası oldu. Bu makale, elektrik motorlarının modern...

Factory I/O: Endüstriyel Otomasyon Eğitimi için Modern Bir PLC Simülasyon Aracı

Factory I/O, öğrenciler, mühendisler ve bakım ekipleri için sürükleyici 3D endüstriyel simülasyonlar sunarak PLC eğitimini dönüştürüyor. Platform, teori ile gerçek dünya otomasyon uygulamaları...