Description

The PLX31-EIP-MBS4 is an industrial-grade communication gateway designed to establish bi-directional data exchange between EtherNet/IP networks and Modbus Serial protocols. By acting as a protocol converter, this module permits EtherNet/IP-enabled controllers, such as Rockwell Automation Logix processors, to seamlessly read and write data to Modbus Serial devices. The gateway features four isolated serial ports, allowing independent configuration for RS-232, RS-422, or RS-485 electrical interfaces. This flexibility enables high-density integration of field instruments, power meters, drives, and flow controllers into modern control systems.

Engineered for demanding industrial environments, this interface module supports both EtherNet/IP Class 1 I/O connections for real-time control and Class 3 messaging for diagnostic data transfer. The dynamic data mapping capabilities allow engineers to optimize throughput, ensuring minimal latency between networks.

Features

  • Four fully independent, isolated serial ports supporting RS-232, RS-422, and RS-485 configurations.
  • Supports up to 5 EtherNet/IP Class 3 server connections and 8 Class 1 I/O connections.
  • Bi-directional data mapping between EtherNet/IP and Modbus Serial networks.
  • Configurable serial parameters including baud rate, parity, stop bits, and handshaking.
  • Diagnostics and monitoring available via web-based configuration tools.
  • Wide operating temperature range suited for unconditioned control cabinets.

Applications

  • SCADA and HMI integration with legacy Modbus field devices.
  • Power distribution networks integrating Modbus RTU power meters.
  • Oil and gas flow metering system communication.
  • Water and wastewater remote telemetry integration.
  • Industrial manufacturing assembly line automation.

Technical Specifications

ParameterSpecification
Manufacturer ProSoft Technology
Part Number / Model PLX31-EIP-MBS4
Product Type EtherNet/IP to Modbus Serial Gateway
Number of Serial Ports 4 (isolated)
Serial Interface Types RS-232, RS-422, RS-485
EtherNet/IP Class 3 Connections 5
EtherNet/IP Class 1 I/O Connections 8
I/O Connection Size 248 / 248 bytes
Max Requested Packet Interval (RPI) 5 ms per connection
Nominal Input Voltage 24 VDC
Allowed Input Voltage Range 10 to 36 VDC
Current Load (Nominal) 300 mA @ 24 VDC
Current Load (Maximum) 610 mA @ 10 to 36 VDC
Operating Temperature -25 degC to 70 degC
Storage Temperature -40 degC to 80 degC
Shipping Weight 3 kg

Connections and Interfaces

Interface PortPhysical Connection TypeSupported Protocols
Ethernet Port RJ45 (10/100 Mbps) EtherNet/IP, TCP/IP
Serial Port 1 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Serial Port 2 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Serial Port 3 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Serial Port 4 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Power Input 3-position terminal block Positive, Negative, GND

Installation Guidelines

  • Mounting: Install on standard 35mm DIN rails. Verify the locking mechanism is secure.
  • Grounding: Connect the dedicated ground terminal on the power connector directly to the panel functional ground using low-impedance copper wire.
  • Wiring: Route communication cabling (Ethernet and Serial) away from high-voltage AC lines to prevent electromagnetic interference.
  • Clearance: Maintain at least 50mm of clearance at the top and bottom of the module to support proper convective cooling.

Compliance and Certifications

  • CE Mark
  • UL/cUL Class I, Division 2
  • ATEX Zone 2
Loading product navigation…

What protocols does the ProSoft PLX31-EIP-MBS4 gateway bridge?

The PLX31-EIP-MBS4 bridges devices on an EtherNet/IP network with devices on Modbus Serial (RTU or ASCII) networks.

Can the serial ports be configured independently?

Yes, all four serial ports are isolated and can be individually configured for RS-232, RS-422, or RS-485 physical layer communication.

What are the power requirements for this gateway?

The module requires a nominal 24 VDC power supply, but supports an input range of 10 to 36 VDC.

How many Class 1 and Class 3 connections does it support?

It supports up to 5 Class 3 Server connections and up to 8 Class 1 I/O connections.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma (resmi tatiller hariç) işlenir ve teslim edilir.


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Birleşik Devletleri

Son Görüntülenen Ürünler

Teknik bilgi

FBD PLC Programlama ile Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robotik tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...

Geçmişe Dönüş: Erken Elektrik Motorları Yeraltı Madenciliğini Nasıl Değiştirdi?

Halatla çalışan DC kompresörlerden bataryalı maden arabalarına kadar, erken madencilik faaliyetleri endüstriyel elektrifikasyonda bir dönüm noktası oldu. Bu makale, elektrik motorlarının modern...

Factory I/O: Endüstriyel Otomasyon Eğitimi için Modern Bir PLC Simülasyon Aracı

Factory I/O, öğrenciler, mühendisler ve bakım ekipleri için sürükleyici 3D endüstriyel simülasyonlar sunarak PLC eğitimini dönüştürüyor. Platform, teori ile gerçek dünya otomasyon uygulamaları...