The Rosemount 1056-01-21-31-AN is a sophisticated dual-channel multi-parameter transmitter designed for demanding liquid analysis. This specific configuration is optimized for Dual Toroidal Conductivity measurements, allowing for simultaneous monitoring of two separate process lines or the calculation of differential conductivity in high-concentration chemical applications.

Technical Specifications

Category Specification
Manufacturer Rosemount (Emerson)
Model 1056
Power Supply 115/230 VAC, 50/60 Hz (No Relays)
Measurement 1 Toroidal Conductivity
Measurement 2 Toroidal Conductivity
Output / Communication Dual 4-20 mA Analog Outputs
Operating Temperature 0 to 55 °C (32 to 131 °F)
Enclosure Rating NEMA 4X / IP66
Shipping Weight 5.0 kg

Measurement Capability

  • Toroidal (Inductive) Method: Ideal for high-conductivity liquids, slurries, or corrosive chemicals that would foul or coat standard contact electrodes.

  • Dual Display: The large, high-contrast LCD displays both measurements simultaneously with user-defined units.

  • Auto-Configuration: The transmitter automatically recognizes the measurement boards upon power-up.


Installation & Wiring Guidelines

  • Mounting Options: The 1056 is versatile and can be mounted via panel-mount (1/2 DIN), pipe-mount, or surface-mount. Ensure the rear cable glands are tightened to maintain the NEMA 4X seal.

  • Power Connection: This unit is configured for 01 (AC Power). Internal jumpers or terminal selection must be checked to match your local supply of 115 VAC or 230 VAC.

  • Sensor Compatibility: This model requires Toroidal sensors (e.g., Rosemount 222, 225, or 228 series). Ensure the sensor cable is properly shielded and routed away from high-power VFD or motor cables.

  • Analog Outputs: The dual 4-20 mA outputs are isolated. They can be mapped to represent Conductivity 1, Conductivity 2, or the temperature of either process.


Frequently Asked Questions (FAQs)

Why choose Toroidal conductivity over Contacting conductivity?

Toroidal sensors are "non-contacting." They use induction to measure conductivity, making them nearly maintenance-free in applications that involve heavy oils, fibrous slurries, or high-acid/base concentrations that would corrode standard sensors.

Does this model include alarm relays?

No. The "01" power option in this specific product code indicates "no relays." If your application requires local high/low alarm triggers, you must utilize the 4-20 mA signals to an external PLC or DCS, or select a different hardware configuration.

How do I calibrate the dual channels?

Calibration is performed through the front-panel membrane keypad. You can perform a "Zero" calibration in air and a "Standard" calibration using a solution of known conductivity or by comparing it to a grab sample.

Is the display visible in direct sunlight?

Yes, the 1056 features a high-contrast, black-on-white LCD that is designed for high visibility in both indoor industrial lighting and outdoor daylight conditions.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White
Country of origin
United States

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...