Only 7 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: IMCPM02

  • Country of origin:Switzerland

  • Product Type: Communication Port Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 680g

  • Dimensions: 355.6 mm x 279.4 mm x 76.2 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The ABB IMCPM02 is a microprocessor-based single-slot wide interface module designed for the INFI 90 system. This device connects the CTT02 Configuration and Tuning Terminal and/or an engineering work station (EWS) to a single INFI 90 process control unit (PCU). It provides a local, reliable interface within the PCU for comprehensive system configuration, tuning, and diagnostics. The IMCPM02 enables operators to configure, tune, and monitor master modules alongside their respective function blocks. It features direct compatibility with existing Network 90 and INFI 90 systems, serving as a functional replacement for the IMSPM01 Serial Port Module and IMCPM01 Configuration Port Module. The module operates efficiently across PCUs utilizing either a module bus or Controlway architecture.

Features

  • Microprocessor-driven architecture occupying a single slot within a standard module mounting unit (MMU).
  • Dual-interface capability supporting both a handheld configuration tuning terminal (CTT) and an engineering work station (EWS) to minimize physical hardware footprints.
  • Comprehensive diagnostic interface featuring one dual-color (red/green) status LED and eight dedicated red error status LEDs.
  • Two onboard eight-pole dipswitches for setting the Controlway/module bus address, configuring baud rates, and enabling specialized diagnostic routines.
  • Front panel reset switch accessible directly through the faceplate window for manual module initialization.
  • Flexible jumper array designed to select between DTE, DCE, or loopback operating modes for the EWS serial port.
  • Expandable installation options accommodating permanent mounting configurations via a dedicated termination module or unit.

Applications

  • Local system tuning, parameter adjustment, and configuration of master modules in INFI 90 process control units.
  • Real-time diagnostic verification and communication testing across intelligent DCS components.
  • Industrial process automation environments requiring a direct serial interface for work station integration.

Ordering Information

Description Part Number Quantity
Module, communication port module IMCPM02 1
Termination module, multi-function processor NIMP01 1
Termination unit, multi-function processor NTMP01 1
Cable, IMCPM02 to termination unit NKTU01 1
Cable, IMCPM02 to termination module NKTU02 1

Technical Specifications

Property Characteristics
Current Consumption 0.81 A maximum, 750 mA typical, at +5 VDC
Power Dissipation 4.1 W maximum, 3.8 W typical
Microprocessor 32 bit processor (16 bit external bus) running at 16 MHz
Memory 128 kbytes of ROM, 256 kbytes of RAM
Serial Ports 1 - isolated RS-232-C at up to 19.2 kbaud
Ambient Temperature 0 to +70 degC (32 to 158 Fahrenheit)
Relative Humidity 5% to 90% R.H. up to 55 degC (131 Fahrenheit) (noncondensing), 5% to 40% R.H. at 70 degC (158 Fahrenheit) (noncondensing)
Atmospheric Pressure Sea level to 3 km (1.86 mi)

Connections/Interfaces

Connector Pin Function
P1 Power / Module Bus / Controlway Connection
P3 Input / Output Interface
P4 CTT Port (5-Pin Round Connector)
P5 EWS Port (DB-25 Connector)
P6 Utility Port

Installation Guidelines

  • Verify the MMU backplane voltages before installing the module; ensure that older system configurations applying -30 VDC are isolated or that jumper J12 is properly configured to avoid potential equipment damage.
  • Set jumper J12 to short pins 2 and 3 if the module is deployed in a standard INFI 90 system to enable redundant Controlway bus operations.
  • Align the circuit board with the top and bottom guide rails of the module mounting unit slot, sliding the module backward until it sits firmly within the backplane connectors.
  • Tighten the two front concentric faceplate screws by turning them 1/2 turn clockwise to lock the assembly into place.
  • For remote or permanent wiring terminations, route the appropriate NKTU01 or NKTU02 cable from the backplane to the corresponding NIMP01 termination module or NTMP01 termination unit.
  • Ensure cabinet power is entirely disconnected before initiating any external termination unit or module wiring procedures.

Compliance and Certifications

  • CSA certified for use as process control equipment in ordinary (non-hazardous) locations.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB IMCPM02 Bailey infi 90 Communication Port Module

What is the primary purpose of the communication module?

The module connects the CTT02 Configuration and Tuning Terminal and an engineering work station to a single INFI 90 process control unit for local configuration, tuning, and diagnostic monitoring.

What are the onboard memory specs for the device?

The device features 128 kbytes of read-only memory (ROM) and 256 kbytes of static random-access memory (RAM).

What are the safe ambient temperature limits for the module?

The module is designed to operate within an ambient temperature range from 0 to +70 degC.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Switzerland
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...