Basler Electric DECS-200-2L Digital Excitation Control System

Basler Electric DECS-200-2L Digital Excitation Control System

Only 1 item(s) left in stock
  • Manufacturer: Basler Electric

  • Product No.: DECS-200-2L

  • Country of origin:United States

  • Product Type: Digital Excitation Control Systems

  • Payment: T/T, Western Union

  • Weight: 6350g

  • Dimensions: 171 mm x 205 mm x 304 mm (D x W x H)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Basler Electric DECS-200-2L is a total digital excitation control system packaged in a single enclosure, designed to control the output voltage, vars, or power factor of synchronous generators by varying DC excitation applied to the exciter field. Operating with 15 Adc continuous rated output across 32 Vdc, 63 Vdc, or 125 Vdc excitation applications, this unit incorporates a pulse-width-modulated (PWM) power stage to deliver regulation stability under non-linear load conditions. The DECS-200-2L style configuration specifies external and internal autotracking functionality paired with a 24/48 Vdc control power supply.

Equipped with a microprocessor-based architecture, the device provides true RMS single- or three-phase sensing for generator voltage, bus voltage, and generator currents. Integrated features include multiple operating modes (Automatic Voltage Regulation, Field Current Regulation, var, and Power Factor modes), soft start voltage buildup, limiters, generator protection functions, sequence of events recording, and oscillography. Local operator interface is provided via a front-panel backlit LCD display, six navigation pushbuttons, status LEDs, and an RS-232 serial port, with an additional RS-485 port supporting Modbus RTU network communication up to 4,000 feet.

Features

  • Microprocessor-based digital regulation with 0.25% voltage regulation accuracy
  • True RMS single-phase or three-phase sensing for generator voltage and bus voltage
  • Multiple operating modes: Automatic Voltage Regulation (AVR), Field Current Regulation (FCR/Manual Mode), var control, and Power Factor (PF) control
  • External and internal autotracking for bumpless mode transfers and dual-unit tracking
  • Pulse-width-modulated (PWM) power stage delivering up to 15 Adc continuous output
  • Configurable Underfrequency compensation or Volts/Hz Ratio Limiter
  • Programmable Soft Start voltage buildup with adjustable rate from 1 to 7200 seconds
  • Integrated limiter controls including Minimum Excitation Limiter (UEL), On-line/Off-line Maximum Excitation Limiters (OEL), and Stator Current Limiter (SCL)
  • Exciter Diode Monitoring (EDM) for open and shorted diode detection on brushless generators
  • Eight integrated generator protective functions with adjustable trip thresholds and time delays
  • Sequence of Events Recording (SER) storing up to 127 event reports with date and time stamps
  • Oscillography data recording capturing up to 8 records and 6 selectable variables
  • Front panel LCD with 64x128 pixel graphic display, navigation pushbuttons, and status LEDs
  • Dual RS-232 ports and one RS-485 port with Modbus protocol support

Applications

  • Synchronous generator excitation voltage regulation
  • Utility grid-connected generator var and power factor control
  • Dual-redundant backup generator excitation systems
  • Industrial power generation facility generator control

Ordering Information

Style Option Code Selection Description
Tracking 2 External/Internal autotracking
Power Supply L 24/48 Vdc control power supply

Technical Specifications

Parameter Specification
Manufacturer Basler Electric
Model DECS-200-2L
Control Power Input Voltage (Style L) 16 to 60 Vdc
Control Power Burden 30 W
AC Operating Power Input (32 Vdc Output) 60 Vac nominal, 56 to 70 Vac +/-10%, 1 or 3 Phase, 50 to 500 Hz, 780 VA burden
AC Operating Power Input (63 Vdc Output) 120 Vac nominal, 100 to 139 Vac +/-10%, 1 or 3 Phase, 50 to 500 Hz, 1570 VA burden
AC Operating Power Input (125 Vdc Output) 240 Vac nominal, 190 to 277 Vac +/-10%, 1 or 3 Phase, 50 to 500 Hz, 3070 VA burden
Minimum Voltage Buildup 3 Vac
Continuous Field Output Current 15 Adc
10-Second Forcing Output Current 30 Adc
Rated Field Output Voltage (32 Vdc Output) 32 Vdc continuous, 50 Vdc 10-sec forcing, 2.13 Ohm min field resistance
Rated Field Output Voltage (63 Vdc Output) 63 Vdc continuous, 100 Vdc 10-sec forcing, 4.2 Ohm min field resistance
Rated Field Output Voltage (125 Vdc Output) 125 Vdc continuous, 200 Vdc 10-sec forcing, 8.3 Ohm min field resistance
Generator Voltage Sensing Ranges 100V/50Hz (85 to 127V), 120V/60Hz (94 to 153V), 200V/50Hz (170 to 254V), 240V/60Hz (187 to 305V), 400V/50Hz (340 to 508V), 480V/60Hz (374 to 600V), 500V/50Hz (425 to 625V), 600V/60Hz (510 to 660V)
Bus Voltage Sensing Ranges 100V/50Hz (85 to 127V), 120V/60Hz (94 to 153V), 200V/50Hz (170 to 254V), 240V/60Hz (187 to 305V), 400V/50Hz (340 to 508V), 480V/60Hz (374 to 600V), 500V/50Hz (425 to 625V), 600V/60Hz (510 to 660V)
Generator Current Sensing Rating 1 Aac and 5 Aac for metering/control; 1 Aac and 5 Aac for cross current compensation
Sensing Burden Voltage: <0.1 VA per phase; Current: <1 VA; Parallel Compensation: <1 VA
Contact Switching Inputs 11 inputs supplied with 24 Vdc for dry contacts
Remote Set Point Auxiliary Inputs Selectable +10 Vdc or 4 to 20 mA
Contact Output Carry Rating 7.0 A resistive @ 24/48/125 Vdc / 120/240 Vac
Contact Output Make/Break Rating 7.0 A @ 24 Vdc, 0.7 A @ 48 Vdc, 0.2 A @ 125 Vdc, 7.0 A @ 120/240 Vac
AVR Regulation Accuracy +/-0.25% over load range at rated power factor and constant frequency
AVR Steady State Stability +/-0.1% at constant load and frequency
AVR Temperature Drift +/-0.5% for 0 to 50 degC change
FCR Regulation Accuracy +/-1.0% of nominal value for 10% input voltage or 20% field resistance change
var Regulation Accuracy +/-2.0% of nominal VA rating at rated frequency
PF Regulation Accuracy +/-0.02 PF for real power between 10% and 100% at rated frequency
Operating Temperature -40 degC to +60 degC (-40 degF to +140 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Salt Fog Resistance Per MIL-STD-810E, Method 509.3 (100 hrs salt fog, 100 hrs drying)
Shock Resistance 15 Gs in each of three mutually perpendicular planes
Vibration Resistance 5-26 Hz: 1.2 Gs; 27-52 Hz: 0.914 mm (.036 in) double amplitude; 53-500 Hz: 5.0 Gs
Dimensions (H x W x D) 12.0 in x 8.08 in x 6.76 in (304 mm x 205 mm x 171 mm)
Weight 14 lbs (6.35 kg)

Connections/Interfaces

Terminal / Port Function
COM0 (Front Panel) RS-232, 9-pin sub-D connector, ASCII commands, 1200 to 19200 baud for local PC
COM1 (Right Side Panel) RS-232, 9-pin sub-D connector, autotracking port for dual DECS-200 units
COM2 (Left Side Panel) RS-485, Modbus protocol, 1200 to 19200 baud, half duplex
B7 / B8 DC Control Power Input (BATT+ / BATT-)
B9 / B10 AC Power Control Input (L / N)
C1 / C2 / C3 / C4 Operating Power Input (GND / A / B / C)
C5 / C6 Exciter Field Output (F+ / F-)
A1 / A2 / A3 Voltage Sensing Inputs (E1 / E2 / E3)
B1 / B2 / B3 Current Sensing Inputs (CTB 1 AMP / 5 AMP / COM)
B4 / B5 / B6 Paralleling CT Cross Current Sensing (CTCC 1 AMP / 5 AMP / COM)
A4 / B1 / A5 / B3 Bus Voltage Matching Inputs
A6 / A7 Auxiliary Current Input (4-20 mAdc, I+ / I-)
A8 / A9 / A10 Auxiliary Voltage Input (+/-10 Vdc, GND / V+ / V-)
A11 / A12 Contact Input: Stop / Start
A13 / A14 Contact Output: Watchdog Relays
A15 / A16 Contact Output: Programmable Relay #1
A17 / A18 Contact Output: Programmable Relay #2
A19 / A20 Contact Output: Programmable Relay #3
A21 / A22 Contact Input: Start Command
A23 / A24 Contact Input: Stop Command
A25 / A26 Contact Input: AVR Regulation Mode Select
A27 / A28 Contact Input: FCR Field Current Regulation Mode Select
A29 / A30 Contact Input: Active Mode Raise
A31 / A32 Contact Input: Active Mode Lower
A33 / A34 Contact Input: Pre-Position Close
A35 / A36 Contact Input: Unit / Parallel Contact (52 L/M)
A37 / A38 Contact Input: Var / PF Control (52 J/K)
A39 / A40 Contact Input: Enable Unit as Secondary (SECEN)
A41 / A42 Contact Input: Alarm Reset (ALRST)
A43 / A44 / A45 RS-485 Output Terminals (A / B / C)

Installation Guidelines

  • Control Power Source Isolation: When using dual AC control power sources, install a Control Power Isolation Transformer (Basler P/N BE31449-001) on the AC control power input.
  • Inrush Mitigation: When energizing the system from a source already at rated power input voltage level, connect an Inrush Current Reduction Module (ICRM-15) to limit inrush current.
  • Redundant System Freewheeling Diode: Install a DECS Freewheeling Diode Module (Basler P/N 9293600101) when implementing dual DECS-200 redundant configurations.
  • Panel Mounting: Mount the enclosure using the six 0.281 in (7.1 mm) diameter clearance holes or use the optional Front Panel Mounting Bracket (Basler P/N 9360107100).
  • Transformer Requirements: Ensure potential transformers are installed on voltage sensing inputs if the line voltage exceeds 600 Vac.
  • Shielding and Grounding: Attach chassis ground to terminal C1 and utilize shielded twisted-pair conductors for low-level analog accessory inputs (+/-10 Vdc or 4-20 mA) and communication channels.

Compliance and Certifications

  • UL Recognized per Std. 508 (UL File Number E97035)
  • CSA Certified per Std. CAN/CSA-C22.2, Number 14 (CSA File Number LR23131)
  • CE Compliant (EMC and LVD directives)
  • Certified per DNV Standard 2.4
  • GOST-R Certified (Gosstandart of Russia)
  • Byelorussian Certified
  • IEEE C37.90.1-1989 Surge Withstand Capability (SWC) and Fast Transient
  • IEEE 421.3 High Pot
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Basler Electric DECS-200-2L Digital Excitation Control System

What control power supply voltage range does this excitation controller require?

This unit features Style L control power, operating across a range of 16 to 60 Vdc with a 30 W burden rating.

What is the difference between internal and external autotracking on the device?

Internal autotracking allows non-active modes within a single controller to match the active mode for bumpless transfer, while external autotracking enables communication between two separate controllers for redundant backup tracking.

What communication interfaces are available for system integration?

The device provides two RS-232 serial ports (front COM0 for local PC configuration and side COM1 for dual-unit autotracking) along with a side RS-485 port supporting Modbus RTU protocol.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

OpenVMS Alpha da ishlayotgan Bailey INFI 90 Symphony HMI larini zamonaviylashtirish

OpenVMS Alpha asosida ishlayotgan eskirgan Bailey Symphony operator stantsiyalarini almashtirish bo‘yicha amaliy qo‘llanma. Unda Alpha emulyatsiyasi, OpenVMS x86 ga ko‘chirish, OPC platformasini...

Nima uchun texnik xizmat ko‘rsatish ma’lumotlari sanoat ishonchliligi uchun muhimdir

Texnik xizmat ko‘rsatish ma’lumotlari ish buyurtmalari, sensor signallari, aktivlar tarixi, xarajatlar va texnik mutaxassislarning bilimlarini bog‘laydi. To‘g‘ri ishlatilganda, u rejalashtirish,...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...