1 of 1

BECKHOFF EK1122 EtherCAT 2-port Junction

BECKHOFF EK1122 EtherCAT 2-port Junction

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EK1122

  • Country of origin:Germany

  • Product Type: EtherCAT Junctions

  • Payment: T/T, Western Union

  • Weight: 75g

  • Dimensions: 24 mm x 100 mm x 52 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Integrating physical segments within an industrial communication network requires robust hardware designed to handle high-speed data routing. The EK1122 2-port EtherCAT junction module enables flexible branching of EtherCAT topologies, allowing the deployment of star and tree networks directly within terminal blocks. This compact terminal interfaces seamlessly with standard EtherCAT Couplers and I/O segments, extending the physical reach and structural configuration of automated production systems.

Operating at a native communication rate of 100 Mbit/s, this junction terminal facilitates direct coupling between various EtherCAT stations using standard shielded Cat.5 Ethernet cables. Because the EK1122 routes standard EtherCAT frames dynamically, no complex configuration or manual IP addressing is required during setup. The module draws its operating power directly from the E-bus backplane, simplifying field wiring while maintaining low power consumption and microsecond-level signal propagation delay.

Features

  • Supports the configuration of physical star topologies in industrial networks.
  • Equipped with two RJ45 bus interfaces for secure connection of downstream stations.
  • Requires zero software configuration, enabling true plug-and-play installation.
  • Extends communication distances up to 100 meters per segment over Cat.5 shielded cable.
  • Powered via internal E-bus connections to eliminate external power cables.
  • Compact, DIN-rail-mountable polycarbonate housing designed for space-constrained panels.

Applications

  • Distributed machinery control systems requiring modular station additions.
  • Robotics and pick-and-place automation utilizing Hot Connect functions.
  • Automotive assembly lines, packaging machinery, and material handling systems.
  • Wind power and HVAC infrastructure demanding robust star network topologies.

Technical Specifications

Parameter Technical Specification
Manufacturer BECKHOFF
Model / Part Number EK1122
Task within EtherCAT System Coupling of EtherCAT junctions / branching
Data Transfer Medium Ethernet/EtherCAT cable (minimum Cat.5), shielded
Distance Between Stations Up to 100 m (100BASE-TX)
Protocol EtherCAT
Propagation Delay Approximately 1 microsecond
Data Transfer Rate 100 Mbit/s
Bus Interface 2 x RJ45
Power Supply Source Via E-bus connection
Current Consumption Typical 220 mA
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
Electromagnetic Compatibility (EMC) Conforms to EN 61000-6-2 (Immunity) / EN 61000-6-4 (Emission)
Protection Rating IP20
Housing Material Polycarbonate
Dimensions (W x H x D) 24 mm x 100 mm x 52 mm
Weight Approx. 75 g

Connections and Interfaces

Interface / Port Connection Type Function Description
X1 Port RJ45 Outgoing EtherCAT port for junction segment 1
X2 Port RJ45 Outgoing EtherCAT port for junction segment 2
E-bus Contacts Slide-on blade contacts Internal system power and backplane data routing

Installation Guidelines

  • Mount securely on standard 35 mm DIN rails conforming to EN 60715.
  • Ensure double slot and key connection is fully engaged when mounting side-by-side with other terminals.
  • Always use shielded Cat.5 or higher network cabling to maintain noise immunity in high-interference environments.
  • Ensure clear ventilation space above and below the module to remain within recommended operating temperature parameters.

Compliance and Certifications

  • CE
  • UL
  • ATEX
  • IECEx
  • cFMus

Does the Beckhoff EK1122 require additional software configuration?

No, the EK1122 2-port EtherCAT junction requires no software configuration. It functions plug-and-play and routes native EtherCAT packets dynamically.

How is the EK1122 junction terminal powered?

The module is powered directly through the E-bus backplane connection of the EtherCAT Terminal segment, requiring no external power wiring.

What cable standard should be used with the RJ45 interfaces?

A minimum of shielded Category 5 (Cat.5) Ethernet or EtherCAT cable is required to maintain signal integrity and meet EMC requirements.

What is the maximum distance supported between stations using the EK1122?

The maximum physical distance supported between stations is 100 meters (conforming to 100BASE-TX).

Are hazardous area certificates available for the EK1122?

Yes, the Beckhoff EK1122 carries ATEX, IECEx, and cFMus certifications for hazardous area installations.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...