Decentralized signal routing in demanding physical environments is optimized with the Beckhoff EP2028-0001 EtherCAT Box, an IP67-rated digital output module designed for mounting directly on machinery without control cabinets. This robust field device manages 8 digital outputs operating at 24 V DC, with each channel engineered to supply up to 2 A of load current. Featuring high-speed EtherCAT system integration, industrial M8 connection interfaces, and comprehensive electrical isolation, it delivers reliable output control for ohmic, inductive, and lamp loads under aggressive physical stress.

Features

  • High Current Output Capacity: Supplies up to 2 A per channel, allowing direct control of heavy actuator loads.
  • Individual Short-Circuit Protection: Each channel is isolated and short-circuit proof, preventing localized faults from disrupting the entire system.
  • Industrial-Grade Sealing: Achieves IP65, IP66, and IP67 protection ratings, safeguarding inner electronics from moisture and particulate ingress.
  • Standardized M8 Connectivity: Utilizes robust M8 interfaces for both high-speed EtherCAT communications and system/peripheral power.
  • Hazardous Location Certification: ATEX Zone 2 approval permits deployment within explosive atmospheres.

Applications

  • Pneumatic valve terminal control and decentralized manifold switching.
  • Direct machine-mount actuator control in automated material handling systems.
  • Automated packaging and washdown environments requiring localized, cabinet-free I/O.
  • Process plants and chemical environments utilizing hazardous area (ATEX) regulations.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Beckhoff
Model Number EP2028-0001
Series EtherCAT Box (EP)
Fieldbus Protocol EtherCAT
Number of Outputs 8 digital outputs
Nominal Output Voltage 24 V DC (-15 percent / +20 percent)
Max. Output Current 2 A per channel (individually short-circuit proof); Sum max. 4 A
Short-Circuit Current Limit Typically 15 A
Switching Delay TON: 200 us (typical); TOFF: 200 us (typical)
System Power Consumption (US) 120 mA from US
Auxiliary Power Current (UP) 20 mA typical + load current
Electrical Isolation 500 V (system/auxiliary power to control logic)
Operating Temperature Range -25 to +60 degC
Storage Temperature Range -40 to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Ex Marking II 3 G Ex nA IIC T4 Gc
Approvals CE, UL, ATEX
Unit Weight Approx. 165 g

Connections and Interfaces

Interface Type Connector Style Assignment Function
EtherCAT Bus Input/Output 2 x M8 socket, shielded, screw type Inbound and downstream EtherCAT network routing
Digital Outputs (0 to 7) 8 x M8 socket, 3-pin, A-coded Pin 1: +24 V DC auxiliary out; Pin 3: GND; Pin 4: Output signal
Power Feed 1 x M8 male socket, 4-pin 24 V DC system power (US) and peripheral power (UP)
Downstream Power 1 x M8 female socket, 4-pin Power distribution loop to subsequent EtherCAT Box units

Empirical Engineering Insights

Alternative Models & Compatibility

When standardizing field wiring layouts, contrast the EP2028-0001 (utilizing compact M8 connectors) with the EP2028-0002 (designed with dual M12 connection ports). Direct interchangeability is straightforward via the EtherCAT configuration files (ESI), although physical wiring adaptations are required if substituting M8 connectors for M12 variants. Ensure your TwinCAT system manager configurations are aligned with the exact hardware suffix to maintain cyclic communication timing.

Application Pitfalls & Engineering Notes

A primary engineering constraint of this module is the 4 A aggregate current limit for all channels combined. While individual outputs can switch up to 2 A, simultaneous high-current operation across multiple channels must not exceed 4 A. Exceeding this collective thermal limit will trip system diagnostic flags and may trigger short-circuit protective mechanisms. Engineers must calculate duty cycles and load profiles during design to avoid nuisance thermal shut-offs in high-load actuator applications.

Commissioning & Wiring Tips

For industrial environments with heavy electromagnetic interference (EMI), ensure the metal mounting brackets of the EtherCAT Box are directly grounded to the machine frame. Use shielded M8 network cables and torque connections to the OEM specification (0.4 Nm) to guarantee IP67 sealing. All unused output or power ports must be fitted with screw-on protective IP67 plastic caps to prevent moisture condensation or particulate contamination from compromising the internal signal paths.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical power sources (both control system US power and peripheral UP power) before mounting, routing cables, or plugging/unplugging connections on the module. Live insertions can damage sensitive solid-state switching elements and compromise communication bus performance.

1
Position and secure the EtherCAT box onto a flat, vibration-resistant machine frame using M3 or M4 screws. Avoid applying excessive torque to the mounting tabs.
2
Connect the incoming EtherCAT bus cable to the top-left M8 socket. Loop downstream EtherCAT segments via the adjacent output socket.
3
Terminate the 4-pin M8 auxiliary power feed (US/UP). Verify that polarity and voltage drops across long cable runs remain within specified operational limits.
4
Secure all M8 actuator leads onto ports 0 through 7. Hand-tighten all knurled locking nuts to secure the IP67-rated seals against external environment infiltration.

What is the collective current limit for the EP2028-0001 module?

The total cumulative current limit (sum of all channels) is 4 A. While individual channels can switch up to 2 A, you cannot run all 8 channels at their individual maximum outputs simultaneously.

Does the EP2028-0001 support Distributed Clocks (DC)?

No, this specific model does not support Distributed Clocks. Cyclic communication timing relies on the standard EtherCAT system cycle.

How does the short-circuit protection behave when tripped?

The output channels are individually short-circuit proof. When a fault is detected on a channel, it switches off independently, with a typical peak short-circuit current limit of 15 A before the hardware safeguard trips.

What is the difference between US and UP power supply pins?

US supplies the control electronics logic and internal system operations of the box, whereas UP supplies the peripheral actuator power required by the outputs. These circuits are electrically isolated up to 500 V.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...