1 of 1

BECKHOFF KL2692 Bus Terminal

BECKHOFF KL2692 Bus Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KL2692

  • Country of origin:Germany

  • Product Type: Bus Terminal

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The KL2692 is a multifunctional Bus Terminal from BECKHOFF, combining 2 potential-free relay outputs (normally-open contacts) and 2 digital 24 V DC inputs in a single compact module. This terminal is designed for efficient signal processing and actuator control, allowing for the switching of ohmic or inductive loads up to 5 A (ohmic). With an electrical isolation of 500 V between the K-bus and field potential, the KL2692 ensures reliable separation in complex automation architectures.

Features

  • 2 potential-free relay outputs (normally-open contacts)
  • 2 digital 24 V DC inputs
  • 2-wire connection technology
  • High switching capacity: 5 A ohmic (AC/DC) per channel
  • Minimum load capacity of 10 mA at 5 V DC
  • Mechanical service life of 2 x 10^7 operating cycles
  • Configuration via Bus Coupler or controller
  • Compact IP20-rated housing for DIN rail mounting

Applications

  • Distributed I/O for relay-based logic control
  • Switching of external contactors or solenoids
  • Digital sensor status acquisition combined with output control
  • Automation systems requiring mixed input/output functionality

Technical Specifications

Category Specification
Manufacturer BECKHOFF
Model KL2692
Number of Outputs 2 (relay, NO contacts)
Number of Inputs 2 (digital 24 V DC)
Max. Switching Current (Ohmic) 5 A AC/DC per channel
Max. Switching Current (Inductive) 2 A AC/DC per channel
Nominal Voltage 30 V DC
Current Consumption (K-bus) typ. 165 mA
Electrical Isolation 500 V (K-bus/field potential)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Weight approx. 60 g
Protection Rating IP20

Installation Guidelines

  • Mount the terminal on a 35 mm DIN rail (EN 60715) and secure it using the integrated locking mechanism.
  • Utilize the double slot and key connection for secure side-by-side assembly.
  • Ensure all connections comply with the 2-wire wiring technology requirements.
  • Maintain the ambient operating temperature between 0 and +55 degC to preserve the operational lifespan of the internal relay contacts.
  • Follow EMC standards EN 61000-6-2/EN 61000-6-4 during wiring to prevent signal interference.

Compliance and Certifications

  • CE
  • UL

What is the switching capacity of the relay outputs on the KL2692?

The relay outputs support up to 5 A for ohmic loads and 2 A for inductive loads per channel.

How are the inputs and outputs configured?

Configuration is performed via the Bus Coupler or the host controller.

What is the expected mechanical lifespan of the relays?

The mechanical lifespan is rated for a minimum of 2 x 10^7 operating cycles.

Are the outputs isolated from the K-bus?

Yes, there is 500 V electrical isolation between the K-bus and the field potential.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...