The Bently Nevada 125800-01 is an internal termination Keyphasor I/O module designed for use with the 3500/25 Enhanced Keyphasor Module within a 3500 Machinery Protection System rack. The 125800-01 receives input signals directly from proximity probes or magnetic pickups and delivers phase and speed timing signals to monitor modules across the rack system. Installed in a full-height rear slot, this non-isolated I/O module provides direct internal wiring terminal connections and rear buffered Keyphasor signal outputs for machine diagnostics and TSI monitoring applications.

Features

  • Direct internal termination connections using Euro-style/screw terminal blocks for transducer field wiring
  • Dual-channel transducer input handling for proximity probe and magnetic pickup signals
  • Rear-panel buffered Keyphasor signal outputs via terminal headers
  • Seamless integration with 3500/25 main half-height cards across legacy and current 3500 system racks

Applications

  • Machinery protection systems requiring once-per-turn or multi-event timing reference signals
  • Shaft rotative speed and phase angle (1X vibration amplitude/phase) tracking
  • Turbine, compressor, and large rotating equipment condition monitoring

Technical Specifications

Parameter Category Specification Details
Manufacturer Bently Nevada
Part Number 125800-01
Input Signal Range +0.8 V to -21.0 V
Input Impedance 21.8 kOhm minimum
Speed/Frequency Signal Range Input: 1 to 1,200,000 cpm (0.017 to 20 kHz); Output: 1 to 99,999 cpm (0.017 to 1667 Hz)
Frequency Signal Accuracy 0.017 to 100 Hz: +/-1 cpm; 101 to 500 Hz: +/-8 cpm; 501 to 20 kHz: +/-1% of cpm
Transducer Power Supply -24 Vdc, 40 mA maximum per channel
Buffered Output Impedance 504 Ohm maximum
Slot Requirement 1 full-height rear slot
Operating Temperature -30 degC to +65 degC (-22 degF to +150 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Relative Humidity 95%, non-condensing
Dimensions (H x W x D) 241.3 mm x 24.4 mm x 103.1 mm (9.50 in x 0.96 in x 4.06 in)
Weight 0.46 kg (1.01 lbs)

Connections/Interfaces

Connector Pin Function
CH 1 - PWR Transducer Power (-24 Vdc) Channel 1
CH 1 - COM Transducer Power Common Channel 1
CH 1 - KPH Keyphasor Signal Input Channel 1
CH 1 - SHLD Transducer Cable Shield Channel 1
CH 2 - PWR Transducer Power (-24 Vdc) Channel 2
CH 2 - COM Transducer Power Common Channel 2
CH 2 - KPH Keyphasor Signal Input Channel 2
CH 2 - SHLD Transducer Cable Shield Channel 2
BUF 1 Buffered Keyphasor Output Channel 1
COM (BUF) Buffered Keyphasor Common Channel 1
BUF 2 Buffered Keyphasor Output Channel 2
COM (BUF) Buffered Keyphasor Common Channel 2
SHIELD System Ground/Shield Connection

 

Installation Guidelines

  • Rack Slot Placement: Mount the I/O module in the full-height rear slot directly behind the corresponding 3500/25 main half-height module position.
  • Wiring & Shielding: Connect transducer field wiring to the internal terminal blocks (PWR, COM, KPH, SHLD). Ensure shield wires are properly landed at the assigned SHLD terminals to prevent signal noise.
  • External Termination Compatibility: Do not attempt to connect External Termination (ET) blocks or cables to this internal termination module.

Compliance and Certifications

  • EMC Directives: European Community Directive 2014/30/EU; Standards EN 61000-6-2, EN 61000-6-4
  • Electrical Safety: European Community Directive 2014/35/EU; Standard EN 61010-1
  • Hazardous Area (cNRTLus): Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC)
  • Hazardous Area (ATEX/IECEx): Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)
  • Maritime Approvals: DNV GL rules for classification (Ships, offshore units); ABS Rules for Condition of Classification Part 1
  • Environmental Compliance: RoHS Directive 2011/65/EU; China RoHS SJ/T 11364-2024
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 125800-01 3500/25 Keyphasor I/O Module

What is the primary function of the I/O module?

The device accepts signals from proximity probes or magnetic pickups and routes timing signals to 3500/25 monitor modules for shaft speed and phase angle measurements.

Does this module support external termination blocks?

No, external termination blocks cannot be used with internal termination I/O modules.

What physical slot does this module occupy in a 3500 rack?

The module occupies one full-height rear slot located directly behind the 3500/25 main card.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

OpenVMS Alpha da ishlayotgan Bailey INFI 90 Symphony HMI larini zamonaviylashtirish

OpenVMS Alpha asosida ishlayotgan eskirgan Bailey Symphony operator stantsiyalarini almashtirish bo‘yicha amaliy qo‘llanma. Unda Alpha emulyatsiyasi, OpenVMS x86 ga ko‘chirish, OPC platformasini...

Nima uchun texnik xizmat ko‘rsatish ma’lumotlari sanoat ishonchliligi uchun muhimdir

Texnik xizmat ko‘rsatish ma’lumotlari ish buyurtmalari, sensor signallari, aktivlar tarixi, xarajatlar va texnik mutaxassislarning bilimlarini bog‘laydi. To‘g‘ri ishlatilganda, u rejalashtirish,...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...