Bently Nevada

Bently Nevada 24765-02-00 korpus kengayishi o‘zgartirgichi yig‘masi

SKU 24765-02-00

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 24765-02-00

  • Country of origin:United States

  • Product Type: Korpus kengayishi o‘zgartirgichlari yig‘malari

  • Payment: T/T, Western Union

  • Weight: 320g

  • Dimensions: 24.1 sm x 11.7 sm x 8.9 sm (9.49 dyuym x 4.61 dyuym x 3.50 dyuym)

  • Shipping port: Xiamen

  • Warranty: 12 months

Tavsif

Yirik energetik bug‘ turbinalarida korpusning issiqlik ta’siridagi o‘sishini uzluksiz kuzatish uchun Bently Nevada 24765-02-00 transduser majmuasi aniq mutlaq siljish qayta aloqasini ta’minlash maqsadida o‘zgarmas tokli chiziqli o‘zgaruvchan differensial transformator (DC-LVDT)dan foydalanadi. Ushbu og‘ir sharoitlarga mo‘ljallangan tizim fizik o‘q bo‘ylab harakatni analog doimiy kuchlanishga aylantirib, nazorat qiluvchi mashina himoyasi tizimlariga konstruktiv kengayishni kuzatish va korpus deformatsiyasi yoki mexanik tiqilib qolishning oldini olish imkonini beradi. O‘zgarmas tokda ishlaydigan konstruksiya tashqi o‘zgaruvchan tok qo‘zg‘atishi va demodulyator modullariga ehtiyojni bartaraf etib, asboblar konturini soddalashtiradi hamda masshtablangan signalni bevosita boshqaruv xonasiga yoki monitor stendiga uzatadi.

Asosiy xususiyatlar

  • 50.8 mm (2.00 dyuym) chiziqli diapazon: Sanoatdagi aylanuvchi mashinalarning o‘rta va katta miqyosdagi korpus siljishini kuzatish uchun optimallashtirilgan.
  • Prujinali qaytishsiz (00-variant): Mexanik prujina tarangligiga tayanmasdan, sensor shtogi ikki yo‘nalishdagi harakatni kuzatishini ta’minlash uchun sirpanadigan turbina tayanchi yoki korpusiga bevosita qattiq mexanik ulashni talab qiladi.
  • O‘zgarmas tokda ishlash: Ichki o‘rnatilgan elektronika doimiy tok quvvatini qabul qiladi va siljishga mutanosib, toza hamda past impedansli doimiy kuchlanish chiqaradi.
  • Mustahkam himoya korpusi: Elektr energiyasi ishlab chiqarish turbina maydonlarida keng tarqalgan yuqori namlik, moy tumani va davriy qizib-sovishga bardosh beradigan qilib ishlab chiqilgan.

Qo‘llanilishi

  • Bug‘ turbinasining issiqlik ta’siridagi korpus kengayishini monitoring qilish.
  • Gaz turbinasining konstruktiv o‘sishini kuzatish.
  • Qozon va ta’minot nasosi poydevorlarining siljishini o‘lchash.
  • Og‘ir sanoat konstruksiyalarining kengayishi va mexanik tekislanishini kuzatish.

Texnik xususiyatlar

Parametr Spetsifikatsiya qiymati
Ishlab chiqaruvchi Bently Nevada
Model raqami 24765-02-00
Transduser turi O‘zgarmas tokli korpus kengayishi transduseri (DC-LVDT)
Chiziqli diapazon varianti 02 (50.8 mm / 2.00 dyuym)
Prujinali qaytish varianti 00 (Prujinali qaytishsiz; qattiq ulash talab etiladi)
Masshtab koeffitsiyenti Nominal 0.404 V/mm (10.25 V/dyuym)
Chastota javobi (-3 dB) 15 Hz
Ishlash harorati -30 dan +100 °C gacha
Ishlab chiqarilgan mamlakat Amerika Qo‘shma Shtatlari (AQSh)
Qurilma og‘irligi 2.3 kg (5.07 funt)
Yetkazib berish og‘irligi (hisoblangan) 3.5 kg (7.71 funt)
Qadoq o‘lchamlari (hisoblangan) 24.1 cm x 11.7 cm x 8.9 cm (9.49 dyuym x 4.61 dyuym x 3.50 dyuym)

Empirik muhandislik xulosalari

Muqobil modellar va moslik

Bently Nevada 24765-02-00 qurilmasi 3500/45 Position Monitor yoki DC-LVDT kirishlari uchun sozlangan eski 3300-seriyali pozitsiya monitorlari bilan bevosita mos keladi. Eski AC-LVDT korpus kengayishi yig‘masini almashtirganda, tashqi AC demodulyator qurilmalarini chetlab o‘tish yoki olib tashlash kerakligini yodda tuting, chunki 24765 qo‘zg‘atish va signalni shartlashni ichki ravishda amalga oshiradi. Xatoli kalibrlash egri chiziqlarining oldini olish uchun monitoring tizimi kanal kartasi DC kuchlanish kirishiga, to‘g‘ri masshtab koeffitsiyenti (10,25 V/in) bilan sozlanganini tekshiring.

Qo‘llashdagi xatolar va muhandislik qaydlari

Ushbu muayyan yig‘ma Option 00 (prujinali qaytishsiz) variantidan foydalanadi, shuning uchun sensor o‘zagi shtogi avtomatik ravishda tortilmaydi. Shtok turbina korpusiga mexanik ravishda shtift bilan mahkamlanishi, boltlanishi yoki vilka yig‘masi orqali bog‘lanishi kerak. Agar bu jismoniy ulanish issiqlik sikllari vaqtida uzilsa yoki sirpansa, o‘zgartirgich oxirgi jismoniy holatida qoladi va monitoring tizimi statik "tekis chiziq" signalini ko‘rsatadi. Bundan tashqari, korpus harakati paytidagi har qanday yonlama yuk yoki burchakli noto‘g‘ri moslashuv ichki ishqalanishga sabab bo‘lib, PTFE tayanch vtulkalarini yeydiradi va o‘lchashda qadalish holatini yuzaga keltiradi.

Ishga tushirish va ulash bo‘yicha maslahatlar

O‘zgartirgichni sovuq uskuna sharoitida o‘rnatayotganda, LVDT o‘zagi fizik yurishining manfiy uchiga yaqin joylashishi uchun mexanik ulanishni sozlang. Bu bug‘ turbinasi qizib, kengayganda foydalanish mumkin bo‘lgan musbat o‘lchash diapazonini maksimal darajada oshiradi. Dala simlari ekranini faqat 3500 monitoring shkafi terminal blokida yerga ulang; ekraning ikkala uchini ham yerga ulash turbina poydevori bilan boshqaruv xonasi asbobi yerga ulanishi orasidagi potensial farqlar sababli yer konturlarini hosil qilishi mumkin.

O‘rnatish bo‘yicha ko‘rsatmalar

MUHIM OGOHLANTIRISH

O‘rnatish yoki o‘zgartirgich yig‘masini jismoniy sozlashdan oldin turbina butunlay to‘xtatilgan, kuchlanishdan uzilgan va atrof-muhit haroratigacha sovigan bo‘lishi kerak. Sovish paytida korpusning konstruktiv siljishlari kuchli siqilish xavfini tug‘diradi. Ulash vaqtida vaqtinchalik kuchlanish sakrashlari ichki LVDT elektronikasiga zarar yetkazmasligi uchun barcha tegishli monitoring konturi quvvatini uzing.

1

Og‘ir himoya korpusini turbina poydevorining qattiq plitasiga yoki tagligiga mahkam o‘rnating va uning korpus kengayishi yo‘nalishiga parallel tekislanganini ta’minlang.

2

LVDT shtokining uchini korpus kronshteyniga yoki sirpanma tayanchga mexanik ravishda ulang. Butun 50,8 mm yurish oralig‘ida hech qanday burchakli siljish yoki qadalish yo‘qligini tekshiring.

3

Integral ulanish qutisi ichidagi DC quvvat ta’minoti liniyalari va signal chiqish kabellarini ulang; korpusni turbina tebranishlaridan ajratish uchun egiluvchan kabel quvuridan foydalaning.

FAQ

00-variant bilan standart prujinali qaytish modelining asosiy farqi nimada?

00-variantda ichki qaytish prujinasi mavjud emas. Bu transduser shtogi har ikki yo‘nalishda ham harakatlanuvchi turbina korpusiga mexanik tarzda mahkamlanishi yoki ulanib qo‘yilishi kerakligini anglatadi. U o‘z-o‘zidan avtomatik tarzda ichkariga qaytmaydi.

24765-02-00 uchun tashqi AC qo‘zg‘atish moduli kerakmi?

Yo‘q. 24765-02-00 doimiy tokli (DC) LVDT hisoblanadi. U doimiy kuchlanishli kirish signalini qabul qiladi va DC signal chiqaradi; uning tarkibida yuqori chastotali qo‘zg‘atish hamda signal demodulyatsiyasini boshqaruvchi ichki elektronika mavjud.

Sovuq turbinadagi nol nuqtani qanday kalibrlash kerak?

Mexanik ulanishni shunday sozlangki, turbina korpusi to‘liq sovuq bo‘lganda transduser manfiy chegaradagi mexanik tirgakka yaqin holatda joylashsin. Bu korpusning issiqlik ta’sirida kengayishi uchun maksimal musbat siljish masofasini saqlab qoladi.

Ushbu transduser yig‘masining keng tarqalgan nosozlik holatlari qaysilar?

Keng tarqalgan muammolarga mexanik noto‘g‘ri moslashuv sababli o‘zak shtogining tiqilib qolishi, mexanik ulanishlarning bo‘shashi tufayli signalning bir darajada qotib qolishi va kuchli vibratsiyali konstruktiv muhit sababli signalning siljishi kiradi.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Allen-Bradley 1771-IG: TTL mantiqi va 5 V sim ulanishlarini tekshirish

Kirish modulini almashtirishdan oldin 1771-IG TTL HIGH/LOW mantiqiy chegaralarini, dala ta’minotidagi pulsatsiyani va 1771-WC ulanishlarini tekshiring.

AKS 33 va AKS 3000: Bosim o‘zgartirgichni almashtirishdan oldingi tekshiruvlar

Danfoss 060G2105, 060G1323 va 060G2109 modellarini bosim diapazoni, ulanish moslamasi, kontur signali va kontroller shkalasi bo‘yicha farqlash uchun dala sharoitida foydalaniladigan tekshiruv...

Almashtirishdan oldin DeltaV SE5009 quvvat muammolarini tashxislash

Emerson SE5009 ni almashtirishdan oldin 24 VDC kirishi, tashuvchi shinasi, chiqish quvvatining pasayishi va signal kontaktlaridagi nosozliklarni aniqlash uchun dala tekshiruv ro‘yxati.

140XSM00200 simulyatori yordamida Quantum kirish signallarini ishga tushirish

Dala simlarini qayta ulashdan oldin Modicon Quantum kirish xaritasi va blokirovkalarini tekshirish uchun 140XSM00200 simulyatoridan foydalanishning nazorat ostidagi ishga tushirish usuli.

PLX32-EIP-MBTCP ni ishga tushirish: quyi tarmoqlar, registrlar va RPI

ProSoft PLX32-EIP-MBTCP uchun tarmoq quyi tarmoqlarini ajratish, registrlar shartnomalari, EtherNet/IP vaqt parametrlari, nosozlik sinovlari va almashtirish qaydlarini qamrab oluvchi ishga tushirish...

Modulni almashtirishdan oldin IC693MDL916 relesining chiqishlarini diagnostika qilish

IC693MDL916 rele buyruqlari, terminal bloklari, yuklama toki, kommutatsiya tezligi va kontakt tomonidagi o‘lchovlar uchun dala nazorat ro‘yxati.