 Bently Nevada 3300/30 olti kanalli harorat monitori eski Bently Nevada 3300 monitoring tizimi uchun mo‘ljallangan olti kanalli harorat monitoring moduli hisoblanadi.
Bu versiya RTD datchiklari o‘rniga termopara (TC) kirishlarini qabul qilish uchun maxsus sozlangan.

U odatda sanoat mashinalaridagi muhim harorat nuqtalarini, jumladan, quyidagilarni monitoring qilish uchun ishlatiladi:

  • Podshipnik metalli harorati

  • Chiqindi gaz harorati

  • Stator chulg‘ami harorati

  • Moylash moyi tizimi harorati

Monitor sozlanadigan signalizatsiya relesi va standart qayd etish qurilmasi chiqishlari orqali uzluksiz himoyani ta’minlab, turbina, kompressor va generator qurilmalarida ishonchli termik nazoratni kafolatlaydi.


Texnik xususiyatlar

1. Kirishlar

Kirish sig‘imi

  • Ko‘pi bilan oltita (6 ta) mustaqil termopara kirishini qo‘llab-quvvatlaydi

  • Har bir kanal mustaqil ishlaydi

Qo‘llab-quvvatlanadigan termopara turlari

  • Turi J — Temir / konstantan

  • Turi K — Xromel / alyumel

  • Turi E — Xromel / konstantan

  • Turi T — Mis / konstantan

Sovuq ulanish kompensatsiyasi

  • Terminal blokida ichki kompensatsiya ta’minlangan

  • Atrof-muhit haroratidagi o‘zgarishlar sabab yuzaga keladigan o‘lchash siljishini avtomatik tuzatadi

  • Ishlash muhitlarida harorat aniqligining barqarorligini ta’minlaydi


2. Signalni shartlash

Aniqlik

  • Signalning  ±2,2%i doirasida, shuningdek termopara xatoligi

  • Etalon harorat:
    +25°C (+77°F)

Uzilgan termoparani aniqlash

Monitor termopara zanjiri uzilganda nosozlikni avtomatik aniqlash funksiyasini o‘z ichiga oladi.

Tanlanadigan javob rejimlari:

  • Yuqori diapazonga majburlash — Ko‘rsatkichni yuqori qiymatga majburlaydi

  • Past diapazonga majburlash — Ko‘rsatkichni past qiymatga majburlaydi

Bu funksiya harorat himoyasisiz mashinaning ishlashini oldini oladi.

Skanerlash tezligi

  • Barcha olti kanal taxminan quyidagi tezlikda skanerlanadi:

Har siklga 0,5 soniya

Bu skanerlash tezligi tebranish signallariga nisbatan harorat o‘zgarishlari asta-sekin sodir bo‘ladigan mashinalarni himoya qilish tizimlari uchun xosdir.


3. Chiqishlar

Qayd etish qurilmasi chiqishlari

Foydalanuvchi tomonidan dasturlanadigan analog chiqishlar:

  • +4 dan +20 mA gacha

  • 0 dan −10 VDC gacha

  • +1 dan +5 VDC gacha

Buferlangan chiqishlar

Diagnostika va monitoring maqsadlarida mavjud:

  • Old paneldagi koaksial ulagichlar

  • Orqa terminal blokidagi ulanishlar

  • Har bir kanal uchun bitta buferlangan chiqish

Bu chiqishlar odatda quyidagilarga ulanadi:

  • DCS tizimlari

  • PLC tizimlari

  • Ma’lumotlarni qayd etish qurilmalari

  • Holatni monitoring qilish dasturi


4. Signalizatsiya va displey

Displey

  • 7 segmentli LCD harorat displeyi

  • Haroratning real vaqtdagi qiymatini ko‘rsatadi

Kanalni tanlash:

  •  Display tugmasidan foydalaning

  • 1-kanaldan 6-kanalgacha ketma-ket o‘tadi

Signalizatsiya o‘rnatma nuqtalari

Har bir kanal signalizatsiyani mustaqil sozlashni qo‘llab-quvvatlaydi:

  • Ogohlantirish signali

  • Xavf signali

Har ikkala chegara to‘liq sozlanadi.

OK indikatori

 OK LED indikatori tizim holatini, jumladan, quyidagilarni uzluksiz nazorat qiladi:

  • Monitor elektronikasi

  • Termojuft sensorlari

  • Dala simlarining yaxlitligi


Buyurtma haqida ma’lumot

Buyurtma formati

3300/30-AXX-BXX-CXX-DXX-EXX

A — To‘liq shkala diapazoni opsiyasi

Kod Harorat diapazoni
01 0 dan 100°C gacha
02 0 dan 200°C gacha
03 0 dan 500°C gacha
04 0 dan 1000°C gacha
05 32 dan 212°F gacha
06 32 dan 392°F gacha
07 32 dan 932°F gacha
08 32 dan 1832°F gacha

B — Termojuft kirishi opsiyasi

Kod Termojuft turi
01 J turi
02 K turi
03 E turi
04 T turi

C — Signalizatsiya relesi opsiyasi

Kod Tavsif
00 Relesiz
01 Epoksi bilan yopilgan rele
02 Germetik yopilgan rele

D — Agentlik tomonidan tasdiqlash opsiyasi

Kod Sertifikatlash
00 Talab etilmaydi
01 CSA / NRTL / C
02 ATEX bo‘yicha o‘z-o‘zini sertifikatlash

E — Xavfsizlik to‘sig‘i opsiyasi

Kod Tavsif
00 Yo‘q
01 Tashqi to‘siqlar
02 Ichki to‘siqlar

Muhandislik va o‘rnatish bo‘yicha qo‘llanma

Joy talabi

 3300/30 harorat monitori quyidagicha:

Ikki kenglikdagi modul

O‘rnatish talabi:

  • 3300 stoykasida ikki (2) ta slot egallaydi

Bu modernizatsiya yoki kengaytirish loyihalarida stoyka sig‘imini rejalashtirishda muhim.


Termojuft ulash simiga qo‘yiladigan talab

Har doim termojuft turiga mos keladigan to‘g‘ri termojuft uzaytirish simi dan foydalaning.

Misollar:

  • K turi → K turi uzaytirish simi

  • J turi → J turi uzaytirish simi

Standart mis simdan foydalanish quyidagilarni keltirib chiqaradi:

  • Ulanish nuqtasi kuchlanishidagi xatolar

  • Harorat o‘lchovining siljishi

  • Kalibrlashning noaniqligi

Bu maydondagi o‘rnatishdagi eng keng tarqalgan xatolardan biridir.


Yerga ulash amaliyoti

Tavsiya etilgan yerga ulash usuli:

Termojuft ekranini faqat monitor stoykasida yerga ulang

Bir nechta nuqtada yerga ulashdan saqlaning.

Noto‘g‘ri yerga ulash quyidagilarga olib kelishi mumkin:

  • Yer konturlari

  • Signal shovqini

  • Harorat ko‘rsatkichlarining beqarorligi

Quyidagilardan foydalanishda alohida e’tibor talab etiladi:

Uchi yerga ulangan termojuftlar

Bu sensorlar yerga ulash konfiguratsiyasiga nisbatan sezgirroq.


Sovuq ulanish nuqtasi muhitini boshqarish

Monitor stoykasini quyidagi joylarga o‘rnatmang:

  • Haroratning tez o‘zgarishi

  • Klemmalar bloklari bo‘ylab kuchli havo oqimi

  • Yuqori issiqlik gradientlari

Bu sharoitlar ichki sovuq ulanish nuqtasi kompensatsiyasining aniqligiga ta’sir qilishi mumkin.

Odatda muammoli joylar:

  • Ventilyatsiya kanallari yaqinida

  • Turbina chiqindi gazlari yo‘llariga yaqin

  • Issiqlikdan himoyalanmagan tashqi panellar

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Multicolor
Country of origin
United States
Power source
DC Power

Technical knowledge

Allen-Bradley 1771-IG: TTL mantiqi va 5 V sim ulanishlarini tekshirish

Kirish modulini almashtirishdan oldin 1771-IG TTL HIGH/LOW mantiqiy chegaralarini, dala ta’minotidagi pulsatsiyani va 1771-WC ulanishlarini tekshiring.

AKS 33 va AKS 3000: Bosim o‘zgartirgichni almashtirishdan oldingi tekshiruvlar

Danfoss 060G2105, 060G1323 va 060G2109 modellarini bosim diapazoni, ulanish moslamasi, kontur signali va kontroller shkalasi bo‘yicha farqlash uchun dala sharoitida foydalaniladigan tekshiruv...

Almashtirishdan oldin DeltaV SE5009 quvvat muammolarini tashxislash

Emerson SE5009 ni almashtirishdan oldin 24 VDC kirishi, tashuvchi shinasi, chiqish quvvatining pasayishi va signal kontaktlaridagi nosozliklarni aniqlash uchun dala tekshiruv ro‘yxati.

140XSM00200 simulyatori yordamida Quantum kirish signallarini ishga tushirish

Dala simlarini qayta ulashdan oldin Modicon Quantum kirish xaritasi va blokirovkalarini tekshirish uchun 140XSM00200 simulyatoridan foydalanishning nazorat ostidagi ishga tushirish usuli.

PLX32-EIP-MBTCP ni ishga tushirish: quyi tarmoqlar, registrlar va RPI

ProSoft PLX32-EIP-MBTCP uchun tarmoq quyi tarmoqlarini ajratish, registrlar shartnomalari, EtherNet/IP vaqt parametrlari, nosozlik sinovlari va almashtirish qaydlarini qamrab oluvchi ishga tushirish...

Modulni almashtirishdan oldin IC693MDL916 relesining chiqishlarini diagnostika qilish

IC693MDL916 rele buyruqlari, terminal bloklari, yuklama toki, kommutatsiya tezligi va kontakt tomonidagi o‘lchovlar uchun dala nazorat ro‘yxati.