Bently Nevada

Bently Nevada 3500/15-01-00-00 3500 seriyali quvvat manbai moduli

SKU 3500/15-01-00-00

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 3500/15-01-00-00

  • Country of origin:United States

  • Product Type: PLC quvvat manbai modullari

  • Payment: T/T, Western Union

  • Weight: 320g

  • Dimensions: 25,0 sm x 15,0 sm x 10,0 sm

  • Shipping port: Xiamen

  • Warranty: 12 months

Tavsif

3500 mashinalarni himoyalash tizimi uchun ishonchli quvvatni o‘zgartirish va konditsiyalashni ta’minlaydigan Bently Nevada 3500/15-01-00-00 yuqori uzluksiz ishlash talablari bo‘lgan sanoat monitoring muhitlari uchun mo‘ljallangan yarim balandlikdagi quvvat manbai modulidir. Ushbu maxsus konfiguratsiya past kuchlanishli AC kirishini qabul qilish, tarmoq quvvatini orqa panel va o‘rnatilgan monitoring kartalari talab qiladigan rostlangan doimiy kuchlanishlarga aylantirish uchun ishlab chiqilgan. Muhim aylanadigan mashinalarni qo‘llash sohalarida ishlatish uchun mo‘ljallangan bo‘lib, muhim himoya stendlari uchun uzluksiz ishlash va signal yaxlitligini ta’minlaydi.

Xususiyatlari

  • Past kuchlanishli AC imkoniyati: Aynan 85 dan 132 Vac rms gacha bo‘lgan diapazondagi tarmoq quvvatlari uchun ishlab chiqilgan.
  • Modulli arxitektura: Yarim balandlikdagi jismoniy dizayn standart 3500 stendi ichida slotlardan samarali foydalanish imkonini beradi.
  • Quvvat manbaini izolyatsiyalash: Quyi oqimdagi stend komponentlarini tarmoqdagi kuchlanish sakrashlari va o‘tkinchi jarayonlardan himoyalash uchun yuqori elektromagnit immunitetni ta’minlaydi.
  • Moslashuvchan konfiguratsiya: Bitta (zaxirasiz) quvvat manbai opsiyasi sifatida sozlangan bo‘lib, muhim bo‘lmagan yoki standartlashtirilgan zavod arxitekturalari uchun juda mos.

Qo‘llanilishi

  • Neft va gazni qayta ishlash zavodlari hamda neft-kimyo mahsulotlarini qayta ishlash bo‘linmalaridagi tebranish monitoringi tizimlari.
  • Bug‘ yoki gaz turbinalarini monitoring qilish majmualari ishlaydigan elektr energiyasi ishlab chiqarish korxonalari.
  • Markazlashtirilgan aylanadigan mashinalarni himoyalash tizimlaridan foydalanadigan suv ta’minoti va oqova suv inshootlari.

Texnik xususiyatlar

Parametr Qiymat
Ishlab chiqaruvchi Bently Nevada
Model seriyasi 3500 seriyali mashinalarni himoyalash tizimi
Quvvat manbai turi (01) Past kuchlanishli AC (85 dan 132 Vac rms gacha)
Chastota diapazoni 47 dan 63 Gts gacha
Ikkilamchi quvvat manbai opsiyasi (00) Quvvat manbaisiz (bitta quvvat manbali konfiguratsiyalar uchun)
Agentlik tasdiqlovlari (00) Mavjud emas
Kelib chiqish mamlakati Amerika Qo‘shma Shtatlari (AQSh)
Jo‘natish og‘irligi (hisoblangan) 4,00 kg
Qadoq o‘lchamlari (hisoblangan) 25,0 sm x 15,0 sm x 10,0 sm

Muqobil modellar va moslik

Eski Bently Nevada 3500/15-01-00-00 past kuchlanishli AC moduli rasman yangilangan 3500/15-05-00-00 quvvat manbai. Yangiroq model yuqori issiqlik samaradorligi uchun mo‘ljallangan optimallashtirilgan ichki rostlash sxemasiga ega. Eski qurilmalarni yangilash yoki almashtirishda yuzaga kelishi mumkin bo‘lgan orqa panel yuklanishi muammolarining oldini olish uchun barcha qo‘shimcha zaxira quvvat manbalari bir xil kirish kuchlanishi tasnifiga ega ekaniga ishonch hosil qiling.

Qo‘llashdagi xatolar va muhandislik qaydlari

Bu qurilma birlamchi quvvat manbali ishlash uchun sozlangan (-00 ikkilamchi opsiyasi). Stendning ishlamay qolishiga yo‘l qo‘yib bo‘lmaydigan muhim himoya arxitekturalarida ikki tomonlama zaxiralangan konfiguratsiyalarni tanlash kerak. Birlamchi quvvat manbali stenddan foydalanish elektr tarmog‘idagi kiruvchi liniyada kuchlanish pasayishi yoki mahalliy komponent nosozligi yuz berganda tizim monitoringining to‘liq yo‘qolishiga olib keladi. Issiqlikni tarqatish uchun 3500 stendining yuqori va pastki qismida yetarli shamollatish bo‘shlig‘i mavjudligini doimo ta’minlang, chunki ortiqcha harorat sharoitlari modul ichidagi filtrlovchi kondensatorlarning muddatidan oldin yomonlashishiga olib kelishi mumkin.

Ishga tushirish va simlarni ulash bo‘yicha maslahatlar

Xavfsiz texnik xizmat ko‘rsatish uchun kiruvchi quvvat liniyalari stend yaqinida joylashgan maxsus tashqi ikki qutbli avtomatik uzgich orqali o‘tkazilishi kerak. Elektromagnit xalaqitlarning qo‘shni past kuchlanishli datchik kabellariga o‘tishini oldini olish uchun AC kirish quvvati uchun yuqori sifatli ekranlangan kabellardan foydalaning. Barqaror ishlash va kuchlanish sakrashidan to‘g‘ri himoyalanishni ta’minlash uchun 3500 stendining orqa panelidagi korpusni yerga ulash shpilkasi past impedansli asboblar yerga ulash tizimiga bevosita ulanadigan bo‘lishi kerak.

O‘rnatish bo‘yicha ko‘rsatmalar

MUHIM OGOHLANTIRISH

Ushbu modulni chiqarish, o‘rnatish yoki simlarini ulashdan oldin barcha asosiy AC elektr manbalarini uzing hamda xom quvvat liniyalarini blokirovka qiling va yorliqlang. Tizim ishlayotganida klemma bloki va orqa panelda xavfli kuchlanishlar mavjud. Qurilmani to‘liq kuchlanishsizlantirmaslik og‘ir tan jarohati yoki uskunaning ishdan chiqishiga olib kelishi mumkin.

1

3500 stendining asosiy ta’minot zanjiri avtomatik uzgichi to‘liq o‘chirilganini va blokirovka yorlig‘i o‘rnatilganini tekshiring.

2

3500/15-01-00-00 modulini 3500 stendining chap tomonidagi belgilangan slotga ehtiyotkorlik bilan surib kiriting va orqa panel konnektorlariga to‘liq o‘rnashguncha davom eting.

3

Old panelni yerga ulash va mexanik tebranishlar modulni joyidan chiqarib yuborishining oldini olish uchun korpusni mahkamlovchi vintlarni mahkam torting.

4

AC quvvat ta’minoti simlarini kirish klemmasiga ulang, kuchlanish berishdan oldin barcha qutblar va himoya yerga ulash ulanishlarini qayta tekshiring.

FAQ

3500/15-01-00-00 quvvat ta’minoti modulining kirish kuchlanish diapazoni qanday?

Bu modul past kuchlanishli o‘zgaruvchan tok kirishi uchun sozlangan bo‘lib, 47–63 Hz chastota diapazonida nominal 85–132 Vac rms oralig‘ida ishonchli ishlaydi.

Bu modul ikkita zaxiralangan quvvat konfiguratsiyasini qo‘llab-quvvatlaydimi?

Maxsus -00-00 suffiksi ushbu konfiguratsiyada zaxira quvvat ta’minoti sozlanmaganini bildiradi. Zaxiralangan konfiguratsiyalar uchun orqa platada ikkinchi mos quvvat ta’minoti moduli tanlanishi va sozlanishi kerak.

Ushbu eski quvvat ta’minoti modulining rasmiy o‘rnini bosuvchi modul qaysi?

Eski 3500/15-01-00-00 moduli rasman 3500/15-05-00-00 moduli bilan almashtirilgan; u yaxshilangan issiqlik boshqaruvi va o‘tkinchi kuchlanishlardan himoyalanish imkoniyatlariga ega.

Stend ishlayotgan paytda ushbu quvvat ta’minotini issiq almashtirishim mumkinmi?

Agar siz bitta quvvat ta’minoti konfiguratsiyasidan foydalansangiz (-00 opsiyasi ko‘rsatganidek), modulni issiq almashtira olmaysiz. Tizimning to‘liq uzilib qolishining oldini olish uchun avval stenddagi quvvat to‘liq o‘chirilishi kerak.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

AS-Interface tarmoqlarini taxminsiz ishga tushirish

Ishonchli aktuator-sensor tarmoqlari uchun topologiya, quvvat va kuchlanish pasayishini tekshirish, adreslash, PLC xaritalash, nosozlik sinovlari hamda texnik xizmat ko‘rsatish qaydlarini qamrab...

Chastota o‘zgartirgichlar uchun tarmoq reaktorlari va chiqish filtrlarini tanlash

Chiziq reaktorlari, garmonik filtrlar, chiqish reaktorlari, dV/dt filtrlari va sinusoidal filtrlar turli VFD elektr sifati hamda motor kabellari muammolarini qanday hal qilishini va ularni xavfsiz...

Yorug‘likda va qorong‘ilikda ishlaydigan fotoelektrik sensor mantiqi

Yorug‘likda ishga tushuvchi va qorong‘ilikda ishga tushuvchi fotoelektrik datchik rejimlarining to‘siq nurli, retroreflektorli va diffuz sezish, PNP/NPN ulanishi, PLC mantiqi, ishga tushirish hamda...

Shoot-throughsiz H-bridge motor drayverlarini loyihalash

H-bridge motor drayverlari bo‘yicha amaliy qo‘llanma: kommutatsiya holatlari, o‘lik vaqt, induktiv tok yo‘llari, PWM tanlovlari, himoya, PCB joylashuvi, PLC bilan interfeys va bosqichma-bosqich ishga...

Mitsubishi FX PLC ketma-ketliklarini STL va RET yordamida loyihalash

Mitsubishi FX PLC STL va RET ko‘rsatmalari konveyer va pnevmatik ketma-ketliklarni qanday tuzishini amaliy holat dizayni, o‘tish mantiqi, vaqt tugashi nazorati, diagnostika va xavfsiz qayta ishga...

DIN klapan ulagichlarini tanlash va nosozliklarni bartaraf etish

DIN uslubidagi klapan ulagichlarini tanlash, ulash va diagnostika qilish bo‘yicha amaliy qo‘llanma: shaklni aniqlash, g‘altak kuchlanishi, so‘ndirish, qutblilik, germetiklik, ishga tushish vaqti...