1 of 1

EL3002 | BECKHOFF | EtherCAT Terminal Analog Input Module

EL3002 | BECKHOFF | EtherCAT Terminal Analog Input Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL3002

  • Country of origin:Germany

  • Product Type: EtherCAT Terminal

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The EL3002 is a 2-channel analog input terminal manufactured by Beckhoff, designed for high-precision voltage measurement within EtherCAT automation systems. It processes signals in the ±10 V range with 12-bit resolution, providing reliable data for industrial monitoring and control. The module utilizes a single-ended input technology and features configurable filtering options, including FIR and IIR filters, to ensure signal integrity.

Features

  • 2-channel analog input (±10 V)
  • 12-bit resolution (16-bit internal representation)
  • Configurable input filter limit frequency (1 kHz)
  • Integrated limit value monitoring and overload status indication
  • Electrical isolation of 500 V between E-bus and field potential
  • Compact housing with signal LEDs for diagnostic feedback

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Model EL3002
Number of Inputs 2 (single-ended)
Signal Voltage -10 to +10 V
Resolution 12 bit
Conversion Time 0.625 ms (configurable)
Input Filter Frequency 1 kHz
Internal Resistance > 130 kΩ
Dielectric Strength Max. 30 V
Current Consumption (E-bus) Typ. 130 mA
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC

Installation Guidelines

  • DIN Rail Mounting: Secure the EL3002 onto a 35 mm DIN rail (EN 60715). Use the integrated double slot and key connection for reliable side-by-side assembly.
  • Wiring: The terminal accepts solid (0.08–2.5 mm²) and flexible (0.14–1.5 mm²) conductors. Use a screwdriver for spring-loaded terminal actuation. Strip wires to a length of 8–9 mm.
  • Environmental: The unit is IP20 rated. Ensure installation in a clean, temperature-controlled environment within the specified -25 to +60 degC range.
  • Hazardous Areas: Complies with ATEX (II 3 G Ex nA IIC T4 Gc). Ensure all local safety regulations are followed when integrating into potentially explosive atmospheres.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock: Conforms to EN 60068-2-6 / EN 60068-2-27

What is the voltage input range of the EL3002?

The EL3002 supports a signal voltage range of -10 V to +10 V.

Does the EL3002 require manual address configuration?

No, this EtherCAT terminal does not require any manual address or configuration settings.

What is the conversion time for the input signals?

The default conversion time is 0.625 ms, which is configurable by the user.

What kind of signal filtering is available?

The module features activatable FIR/IIR filters to help manage signal noise and improve measurement accuracy.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Dots
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...