FC-051PK18S2E20H3XXCXXXSXXX Danfoss VLT Micro Drive 0.18kW VFD

FC-051PK18S2E20H3XXCXXXSXXX Danfoss VLT Micro Drive 0.18kW VFD

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: FC-051PK18S2E20H3XXCXXXSXXX

  • Country of origin:United States

  • Product Type: Frequency Converter

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The FC-051PK18S2E20H3XXCXXXSXXX (FC-051PK18S2E20H3XXCXXXSXXX) is an ultra-compact frequency converter from the Danfoss VLT® Micro Drive FC 051 series, specifically engineered for low-power applications at 0.18 kW (0.25 hp). This single-phase 200-240 VAC drive is designed for high-density integration in small machinery, providing precise motor control with a minimal footprint. Despite its small M1 frame size, the FC-051PK18 includes professional features like Coated PCBs for environmental protection and an integrated H3 RFI filter (Class A1/B) to ensure electromagnetic compatibility in commercial and industrial settings. It is the ideal solution for controlling small fans, pumps, and conveyor belts where reliability and energy efficiency are required in a chassis-mount format.

Suffix Breakdown

The model code FC-051PK18S2E20H3XXCXXXSXXX specifies a precise hardware configuration tailored for small-scale automation:

  • FC-051: Part of the VLT® Micro Drive series.

  • PK18: Designates a power rating of 0.18 kW (0.25 hp).

  • S2: Single-phase input for 200-240 VAC mains voltage.

  • E20: IP20 / Chassis enclosure rating, requiring panel mounting.

  • H3: Integrated RFI Filter Class A1/B (Category C1) for maximum noise suppression.

  • X (Brake): No integrated brake chopper.

  • X (LCP): Supplied without a Local Control Panel (must be ordered separately).

  • C: Conformal Coating on PCBs for resistance against dust and moisture.

  • SXXX: Equipped with the latest standard software release.

  • M1: The most compact frame size in the FC 051 series.

Technical Specifications

Feature Specification
Model FC-051PK18S2E20
Brand Danfoss
Power Rating 0.18 kW / 0.25 hp
Mains Voltage 200 - 240 VAC (Single-phase)
Output Voltage 0 - 100% of supply voltage (3-phase)
Frame Size M1
RFI Category Class A1/B (C1) Integrated
PCB Protection Conformal Coating (Class 3C3)
Operating Temp -10 to 50 deg C (with derating)
Net Weight Approx. 1.1 kg
Shipping Weight 3.0 kg

Technical FAQs

How do I program the drive if it is supplied without an LCP?

The FC-051PK18 requires an external Local Control Panel (LCP 11 or LCP 12) for manual parameter adjustment. Alternatively, you can use the Danfoss MCT 10 setup software via a PC interface. This "no LCP" version is cost-effective for high-volume OEMs who pre-program drives before shipment.

Can this single-phase drive control a standard three-phase motor?

Yes. The FC-051PK18 takes single-phase 230V input and converts it to a pulse-width modulated (PWM) three-phase 230V output. This allows you to run industrial three-phase motors (wired in Delta for 230V) in locations where only single-phase power is available.

What environments is the "Coated PCB" version suitable for?

The "C" suffix indicates that the internal circuit boards are coated to protect against humidity, salt air, and conductive dust. This makes the drive suitable for use in environments like commercial kitchens, greenhouses, or small-scale industrial workshops where airborne contaminants are present.


Engineering & Installation Guide

  • M1 Frame Mounting: The M1 frame is designed for DIN-rail or backplate mounting. To ensure proper thermal management, maintain at least 100 mm of clearance above and below the unit. Side-by-side mounting is supported without derating, allowing for maximum cabinet space utilization.

  • EMI/RFI Grounding: To achieve the benefits of the H3 Class A1/B filter, you must use shielded motor cables. The shield should be connected to the metal decoupling plate of the drive using the provided 360-degree clamps. This is essential for preventing interference with nearby sensors or household electronics.

  • Commissioning for Low Power: When configuring the 0.18 kW drive, ensure the Motor Current (Parameter 1-24) is set accurately. Because the current is very low, even small deviations can lead to poor torque performance or false "No Motor" alarms. Perform an Automatic Motor Adaptation (AMA) for the best results.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...