GE Fanuc IC693ALG391 Series 90-30 analog tok chiqish moduli
SKU IC693ALG391
In stock
1 review
12-month warranty
Free returns within 30 days
Manufacturer:
General Electric
Product No.:
IC693ALG391
Country of origin:United States
Product Type:
Analog tok chiqish moduli
Barcode:
8537101190
Payment:
T/T, Western Union
Weight:
450g
Dimensions:
200 mm × 150 mm × 60 mm
Shipping port:
Xiamen
Warranty:
12 months
Tavsif
IC693ALG391 GE Fanuc Series 90-30 dasturlashtiriladigan mantiqiy boshqaruvchisi platformasi uchun ishlab chiqilgan, yuqori unumdorlikka ega 2 kanalli analog tok chiqish modulidir. Joyni tejovchi, bitta slotli ushbu interfeys platasi markaziy boshqaruv xostidan olingan 12-bitli raqamli ikkilik qiymatlarni aniq boshqaruv ilovalari uchun barqaror, izolyatsiyalangan, sanoat darajasidagi analog chiqish toklariga aylantiradi. 4–20 mA yoki 0–20 mA standart chiqish diapazonlarida ishlaydigan modul har bir dasturlashtiriladigan boshqaruvchi CPU I/O skanerlash sikli davomida ikkala kanalda to‘liq ichki raqamli-analog o‘zgartirishlarni bir vaqtda bajarish orqali konturlarni sinxron yangilashni ta’minlaydi. Yuqori tezlikdagi ichki galvanik optik izolyatsiya buferlari yuqori kuchlanishli sakrashlarni to‘sadi va faol maydon konturi kabellari bilan past kuchlanishli mantiqiy orqa panel tomoni o‘rtasidagi sanoat elektromagnit shovqin xalaqitlarini bartaraf etadi.
Xususiyatlari
Maxsus ichki 12-bitli raqamli-analog o‘zgartirgich arxitekturasi bilan boshqariladigan, yuqori tezlikdagi, o‘zaro alohida izolyatsiyalangan ikkita analog chiqish kanali.
Standart sanoatdagi 4–20 mA yoki kengaytirilgan 0–20 mA ish konturlarini qo‘llab-quvvatlaydigan, dasturiy jihatdan mustaqil ikkita konfiguratsiya profili.
Taxminan 5 millisekundlik bajarilish oralig‘ida ikkala kanal bo‘ylab ma’lumotlarni bir vaqtda o‘zgartirishni amalga oshiradigan integratsiyalangan yuqori tezlikdagi yangilash mantiqi.
Tizim to‘xtatilganda yoki qayta o‘rnatilganda alohida kanallar oxirgi faol chiqish holatini darhol ushlab turishi yoki to‘g‘ridan-to‘g‘ri 0/4 mA ga o‘tishini ta’minlaydigan ilg‘or faol xavfsizlik javob mexanizmi.
Standart past impedansli tok manbaini ta’minlash yoki oddiy tashqi jumper ulanishlari orqali kuchlanish manbai sifatida sozlash imkonini beruvchi ko‘p funksiyali zanjir yo‘nalishini boshqarish.
Maydon simlari terminali va boshqaruv mantiqi o‘rtasida 1500 voltgacha bo‘lgan elektr shovqini hamda umumiy rejimli o‘tkinchi jarayonlarni uzluksiz to‘sish uchun ishlab chiqilgan, yuqori chidamlilikka ega optik izolyatsiya to‘siqlari.
Standart izolyatsiyalangan PLC orqa panelidagi 24 VDC quvvat liniyalari yoki tashqi yordamchi 24 VDC kontur zaxira quvvat manbalaridan foydalanadigan ikki kirishli quvvat arxitekturasi.
Qo‘llanilishi
O‘zgaruvchan tezlikli yuritmalarda chastota etalonini boshqarish va modulyatsiyalangan tezlikni ketma-ket boshqarish konturlari.
Proporsional oqimni boshqarish klapanlari pozitsionerlari va pnevmatik aktuatorlarni muvozanatlash asboblari.
Masofaviy analog asbob yozuvchilari, kontur boshqaruvchilari va taqsimlangan qayta ishlash interfeys bloklari.
Qog‘oz ishlab chiqarish, suvni tozalash va neft-kimyo jarayonlarida parametrlarni profillash.
Texnik xususiyatlar
Elektr xususiyatlari
Parametr
Spetsifikatsiya
Nominal ta’minot kuchlanishi
Izolyatsiyalangan orqa panel shinasidan yoki tashqi kontur quvvat manbaidan +24 VDC
Mantiqiy ta’minot kuchlanishi
Orqa panel orqali bevosita ta’minlanadigan +5 VDC
Tashqi quvvat manbai kuchlanish diapazoni
20–30 VDC
Tashqi quvvat manbai kuchlanishining pulsatsiyasi
Maksimal 10%
Maksimal muvofiqlik kuchlanishi
25 V
Ichki quvvat sarfi (+5V)
+5 VDC mantiqiy ta’minot shinasidan 30 mA
Ichki quvvat sarfi (+24V)
Izolyatsiyalangan +24 VDC orqa panel yoki tashqi quvvat manbaidan 215 mA
Galvanik izolyatsiya to‘sig‘i
Dala tomoni ulanishlari va orqa panel mantiqi o‘rtasida uzluksiz 1500 volt
Ishlash ko‘rsatkichlari
Parametr
Spetsifikatsiya
Raqamli-analogga o‘tkazish ruxsati
12 bitli ikkilik (4096 dan 1 qism)
Kanalni yangilash tezligi
Ikkala chiqish kanali uchun bir vaqtda taxminan 5 millisekund
Chiqish toki diapazonlari
4 dan 20 mA gacha (standart) va 0 dan 20 mA gacha (jumper orqali)
Chiqish kuchlanishi diapazonlari
1 dan 5 V gacha va 0 dan 5 V gacha (tashqi rezistor bilan 2 dan 10 V gacha va 0 dan 10 V gacha)
Ruxsat darajasi (4 dan 20 mA gacha)
Eng kichik qiymatli bit uchun 4 uA (1 LSB = 4 uA)
Ruxsat darajasi (0 dan 20 mA gacha)
Eng kichik qiymatli bit uchun 5 uA (1 LSB = 5 uA)
Ruxsat darajasi (1 dan 5 V gacha)
Eng kichik qiymatli bit uchun 1 mV (1 LSB = 1 mV)
Ruxsat darajasi (0 dan 5 V gacha)
Eng kichik qiymatli bit uchun 1,25 mV (1 LSB = 1,25 mV)
Mutlaq aniqlik (4 dan 20 mA gacha)
25 °C (77 °F) atrof-muhit haroratida +/-8 uA
Mutlaq aniqlik (0 dan 20 mA gacha)
25 °C (77 °F) atrof-muhit haroratida +/-10 uA
Mutlaq aniqlik (1 dan 5 V gacha)
25 °C (77 °F) atrof-muhit haroratida +/-50 mV
Mutlaq aniqlik (0 dan 5 V gacha)
25 °C (77 °F) atrof-muhit haroratida +/-50 mV
Zavod kalibrlash koeffitsiyenti
Raqamli hisobning har bir bosqichi uchun 4 uA ga kalibrlangan
Chiqish yuklamasi parametrlari
Parametr / ishlash rejimi
Spetsifikatsiya / yuklama chegarasi
Foydalanuvchi yuklamasi qarshiligi (tok rejimi)
Maksimal 0 dan 850 omgacha
Chiqish yuklamasi sig‘imi (tok rejimi)
Maksimal 2000 pF
Chiqish yuklamasi induktivligi (tok rejimi)
Maksimal 1 H
Maksimal yuklama (kuchlanish rejimi)
Maksimal 5 mA boshqaruv toki (minimal yuklama qarshiligi 2K om)
Chiqish yuklamasi sig‘imi (kuchlanish rejimi)
Maksimal 2000 pF
Mexanik va fizik xususiyatlar
Atribut
Tavsif
Ishlab chiqaruvchi
GE Fanuc Automation (Industrial Systems)
Kelib chiqish mamlakati
AQSh
Korpus o‘lchami / slot kengligi
Bir slotli modul, yuqori zichlikdagi ixcham joylashuv
Baza platasiga joylashtirish cheklovlari
5 yoki 10 slotli Series 90-30 stendining istalgan mavjud I/O sloti
Modul holati diagnostikasi
Ichki quvvat ta’minoti faol holatini ko‘rsatuvchi bitta yashil old panel LED indikatori
Ulanishlar va interfeyslar
Olinadigan I/O terminal kolodkasi joylashuvi va pinlar taqsimoti
Old tomondagi ulanish yig‘masida dala konturlarini yo‘naltirish, konfiguratsiya jumperlari va yordamchi ta’minot ulanishlarini tartibga solish uchun standart 20 pinli olinadigan terminal kolodkasi ishlatiladi.
Terminal pini
Terminal belgisi
Muhandislik funksiyasi / sxema mosligi
1
VOUT1
1-kanal uchun kuchlanish rejimi chiqish terminali
2
VOUT2
2-kanal uchun kuchlanish rejimi chiqish terminali
3
IOUT1
1-kanal uchun tok rejimidagi manba chiqishi
4
IOUT2
2-kanal uchun tok rejimidagi manba chiqishi
5
RTN1
1-kanal uchun tok konturining qaytish yo‘li tuguni
6
RTN2
2-kanal uchun tok konturining qaytish yo‘li tuguni
7
GND
Ekran yerga ulash nuqtasi / korpus yer shinasiga ulanish
8
GND
Ekran yerga ulash nuqtasi / korpus yer shinasiga ulanish
9
JMPV1
1-kanal uchun kuchlanish rejimini tanlash jumper tuguni
10
JMPV2
2-kanal uchun kuchlanish rejimini tanlash jumper tuguni
11
NC
Ichki ulanish nuqtasi mavjud emas
12
DEF 0
Xavfsiz holat jumper tuguni (standart sozlama 0/4 mA konfiguratsiyasi)
13
NC
Ichki ulanish nuqtasi mavjud emas
14
RANGE 1
1-kanal uchun 0 dan 20 mA gacha shkala diapazoni jumper tuguni
15
NC
Ichki ulanish nuqtasi mavjud emas
16
NC
Ichki ulanish nuqtasi mavjud emas
17
NC
Ichki ulanish nuqtasi mavjud emas
18
24V
Yordamchi tashqi +24 VDC musbat ta’minot kiritish terminali
19
NC
Ichki ulanish nuqtasi mavjud emas
20
RANGE 2
2-kanal uchun 0 dan 20 mA gacha shkala diapazoni jumper tuguni
O‘rnatish bo‘yicha yo‘riqnoma
Uskunaning maksimal ishonchliligi, xavfsizligi va sanoat standartlariga muvofiqligini ta’minlash uchun o‘rnatish vaqtida ushbu tizimli muhandislik protokollariga rioya qiling.
1. Tizim quvvati xavfsizligi va slot cheklovlari
MUHIM OGOHLANTIRISH: QUvVATNI MAJBURIY UZISH
Modulni joylashtirish, sozlash yoki chiqarishdan oldin asosiy kontroller bazaviy platasining quvvat manbai to‘liq uzilganini doimo tasdiqlang. Hech qanday holatda quvvat ostida almashtirmang.
Modulni istalgan kengaytirish yoki CPU bazaviy platasidagi har qanday standart I/O slotiga o‘rnatish mumkin.
Quvvat ta’minotining zaiflashishi va qizib ketishining oldini olish uchun har bir CPU bazaviy platasida bir vaqtning o‘zida ko‘pi bilan 6 ta master modul o‘rnatish bilan cheklaning.
Signal to‘qnashuvining oldini olish uchun o‘rnatilgan har bir modul alohida, jismonan ajratilgan mustaqil tarmoq halqasiga yo‘naltirilganini ta’minlang.
+-------------------------------------------------------------+
| [CPU] | [Slot 2] | [Slot 3] | [Slot 4] | [Slot 5] | [Slot 6] |
| Slot1 | I/O LINK| I/O LINK| I/O LINK| I/O LINK| I/O LINK|
| | Master | Master | Master | Master | Master |
+-------------------------------------------------------------+
|__________ Har bir CPU bazaviy platasi uchun ko‘pi bilan 6 ta modul __________|
2. Aloqa kabellari va ekranlash usullari
Signal xalaqitlarini kamaytirish: 20 kontaktli Honda turidagi old portga ulanadigan barcha dala ulanishlari sanoat darajasidagi ekranlangan o‘ralgan juftlik (STP) kabellari orqali yo‘naltirilishi kerak. Bu RS-422/RS-485 muvozanatlangan liniya signalining yaxlitligini saqlash uchun juda muhim.
Drenaj simini yerga ulash: Yuqori chastotali elektromagnit shovqinni bartaraf etish uchun kabelning tashqi ekranini bevosita tizim ramasi yeriga yoki maxsus shassi yerga ulash shinasiga ulang.
3. Ishga tushirish ketma-ketligi va dastlabki quvvat berish
20 kontaktli Honda turidagi ulagichni birinchi taqsimlangan slave qurilmasiga olib boruvchi ketma-ket liniyaga mahkam ulang.
3
Asosiy quvvatni yoqish
Asosiy shassi quvvat ta’minotini yoqing va LED indikatorlari orqali ishga tushirish ketma-ketligi diagnostikasini diqqat bilan kuzating.
4. O‘rnatishdan keyingi nosozliklarni tiklash amallari
Liniya beqarorligini bartaraf etish: Ketma-ket shinada vaqtinchalik aloqa xatosi, kutish vaqti tugashi yoki paket yo‘qolishi yuz bersa, tizimning normal ishlashini tiklash uchun old paneldagi o‘rnatilgan interfeysdan foydalaning.
Qo‘lda qayta tiklashni ishga tushirish: Old paneldagi maxsus LINK RESTART qo‘lda bosiladigan tugmani mahkam bosing. Bu qotib qolgan xato registrlarini bekor qiladi, tarmoqdagi nosozliklarni tozalaydi va asosiy PLC protsessorini qayta yuklamasdan, ketma-ket aloqa liniyasini darhol sovuq ishga tushirishga majbur qiladi.
FAQ
Xost protsessori STOP rejimiga o‘tsa, analog tok konturi chiqishlarida nima sodir bo‘ladi?
Javob 12-terminal pinidagi DEF 0 jumperiga bog‘liq. Jumper ulanmagan bo‘lsa, zaxira quvvat ulangan taqdirda kanallar oxirgi faol qiymatini saqlab qoladi. Jumper ulangan bo‘lsa, tanlangan diapazonga qarab ular darhol 0 mA yoki 4 mA qiymatiga o‘tadi.
Tok konturi o‘rniga 0 dan 10 V gacha signal chiqarishi uchun modulni qanday o‘zgartirish mumkin?
0 dan 10 V gacha diapazonni sozlash uchun kanal jumper yordamida 0 dan 20 mA gacha diapazonga o‘rnatilishi va standart simli ulanish o‘rniga JMPVx va IOUTx terminallari orasiga yuqori aniqlikdagi 250 omli rezistor o‘rnatilishi kerak.
Bitta asosiy plataga ushbu modullardan eng ko‘pi bilan nechta o‘rnatish mumkin?
Agar modullar quvvatni faqat PLC backplane’idan olsa, bitta asosiy plataga ko‘pi bilan uchta modul o‘rnatish mumkin. Bu cheklovni bartaraf etish va backplane quvvat manbaini ortiqcha yuklamaslik uchun terminal blokiga tashqi 24 VDC quvvat manbai ulanishi kerak.
Modul foydalanuvchi kodi yozgan diapazondan tashqari registr qiymatlarini qanday qayta ishlaydi?
Modul to‘liq diapazonli tok chiqishlari uchun 32000 o‘nlik qiymatgacha masshtablangan 16 bitli 2 ning to‘ldiruvchisi formatidan foydalanadi. Agar 32767 dan katta yaroqsiz ma’lumot qiymati kiritilsa, dasturlash dasturi bu qiymatni rad etadi va qabul qilmaydi.
Chiziq reaktorlari, garmonik filtrlar, chiqish reaktorlari, dV/dt filtrlari va sinusoidal filtrlar turli VFD elektr sifati hamda motor kabellari muammolarini qanday hal qilishini va ularni xavfsiz...
Yorug‘likda ishga tushuvchi va qorong‘ilikda ishga tushuvchi fotoelektrik datchik rejimlarining to‘siq nurli, retroreflektorli va diffuz sezish, PNP/NPN ulanishi, PLC mantiqi, ishga tushirish hamda...
H-bridge motor drayverlari bo‘yicha amaliy qo‘llanma: kommutatsiya holatlari, o‘lik vaqt, induktiv tok yo‘llari, PWM tanlovlari, himoya, PCB joylashuvi, PLC bilan interfeys va bosqichma-bosqich ishga...
Mitsubishi FX PLC STL va RET ko‘rsatmalari konveyer va pnevmatik ketma-ketliklarni qanday tuzishini amaliy holat dizayni, o‘tish mantiqi, vaqt tugashi nazorati, diagnostika va xavfsiz qayta ishga...
DIN uslubidagi klapan ulagichlarini tanlash, ulash va diagnostika qilish bo‘yicha amaliy qo‘llanma: shaklni aniqlash, g‘altak kuchlanishi, so‘ndirish, qutblilik, germetiklik, ishga tushish vaqti...
PLC va mikrokontroller ikkalasi ham qadam va yo‘nalish signallari asosidagi harakatni hosil qila oladi, biroq yoyli payvandlash EMC, I/O himoyasi, diagnostika, texnik xizmat ko‘rsatish qulayligi,...
Choosing a selection results in a full page refresh.