1 of 3

GE IS230TAISH2C Mark VIe TMR DIN Rail Assembly Board

GE IS230TAISH2C Mark VIe TMR DIN Rail Assembly Board

Only 4 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IS230TAISH2C

  • Country of origin:United States

  • Product Type: Terminal Boards

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 2920g

  • Dimensions: 34cm x 22.5cm x 11.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The TMR DIN rail assembly board functions as a high-reliability hardware interface designed for the General Electric Mark VIe control platform. The IS230TAISH2C facilitates critical signal routing and field wiring integration, enabling structured connection pathways for sensors and actuators in mission-critical applications. By supporting Triple Modular Redundancy (TMR) architectures, this board provides cross-channel signal availability and hardware fault tolerance across dual or triple controller infrastructures linked via the high-speed IONet communication protocol. This continuous synchronization and majority voting capability ensure absolute data integrity for continuous process operations in demanding heavy industries like thermal power stations, petrochemical plants, and oil refining infrastructure.

Features

  • Equipped with an onboard heavy-duty terminal block providing up to forty-eight (48) individual field wiring terminals.
  • Supports scalable redundant system architectures, interfacing seamlessly with simplex, dual, or fanned TMR controller layouts.
  • Native alignment with high-speed IONet communication channels to handle precise controller state synchronization and voting tracking.
  • Designed for standard 35 mm DIN-rail mounting configurations to optimize high-density cabinet layouts and installation workflows.
  • Certified under strict industrial safety listings for dependable deployment in hazardous and non-hazardous operating zones.

Applications

  • Steam and Gas Turbine Protection Systems
  • Triple Modular Redundant (TMR) Control Architectures
  • Emergency Interlocking and Safety Shutdown Panels
  • Power Generation Plant Automation Infrastructure
  • Hazardous Area Field Instrument Distribution Links

Technical Specifications

Parameter Configuration and Rating Value
Manufacturer GE (General Electric)
Model IS230TAISH2C
Series Mark VIe Control System
Product Type TMR DIN Rail Assembly Board
Mounting Format Standard 35 mm DIN-Rail
Terminal Capacity Forty-eight (48) screw termination points
Country of Origin United States (USA)
Availability In Stock / Factory New
Standard Repair Turnaround 3 to 5 business days

Installation Guidelines

  • DIN Rail Mounting: Mount the assembly board horizontally or vertically on a standard 35 mm symmetric DIN rail. Ensure the locking tabs are completely engaged with the rail structure to resist cabinet vibrations.
  • Field Conductor Wiring: Strip field device and sensor signaling cables to the standard specified insulation length. Secure individual leads into the 48-point terminal block using calibrated screwdrivers to maintain accurate electrical contact tension.
  • Shielding and Data Integrity: Route incoming low-voltage sensor lines through dedicated grounded wire trays. Connect cable drain wires directly to the designated cabinet enclosure earth bar to suppress industrial electromagnetic interference (EMI).

Compliance and Certifications

  • UL E207685 Certification (Non-Hazardous Environments)
  • Class I, Division 2, Groups A, B, C, D
  • Class I, Zone 2, Group IIC

What is the maximum field connection capacity of this terminal assembly?

The board features a high-density terminal block configuration that accommodates up to forty-eight (48) distinct field device and sensor wire connections.

Why do multiple controllers synchronize state parameters across this hardware system?

Synchronization is required to maintain consistent and coordinated voting logic across the redundant network, protecting data integrity and reducing unexpected operational downtime.

What primary network handles the continuous data exchange between redundant nodes?

Redundant controllers utilize high-speed IONet channels to exchange calculated variables, internal timers, counter parameters, and real-time logic signals continuously.

Is this assembly board certified for installation in hazardous industrial zones?

Yes, it holds safety certifications for deployment in Class I, Division 2, Groups A, B, C, D and Class I, Zone 2, Group IIC environments.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black Green Silver
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...