| Spetsifikatsiya |
Ishlab chiqaruvchi |
| GE Multilin / GE Grid Solutions |
Faza / yerga ulash / sezgir CT kirishlari |
| 5 A ikkilamchi |
Faza / yerga ulash CT o‘zgartirish diapazoni: 0,01 dan 20 × CT gacha |
| Sezgir yerga ulash CT o‘zgartirish diapazoni |
0,005 dan 1,000 × CT gacha |
| Tok kirishidagi yuklama |
5 A da 0,2 VA dan kam |
| Shina / liniya kuchlanishi kirishlari |
Faza–neytral orasida 50 V dan 240 V gacha |
| Boshqaruv quvvati kirish diapazoni (HI) |
88–300 VDC; 48–62 Hz da 70–265 VAC |
| Quvvat sarfi |
Nominal 25 VA, maksimal 35 VA |
| Kuchlanish yo‘qolganda ushlab turish vaqti |
30 ms |
| Mantiqiy kirishlar |
14 ta kontaktli va/yoki virtual, faqat 6 ta virtual |
| Analog kirish |
0–1 mA, 0–5 mA, 0–10 mA, 0–20 mA yoki 4–20 mA (375 om impedans) |
| Analog chiqishlar |
8 ta faol kanal, 4–20 mA (maksimal yuklama 600 om), to‘liq izolyatsiyalangan |
| Chiqish relesi |
1 TRIP (A shakli), 1 CLOSE (A shakli), 5 AUXILIARY (C shakli), 1 SELF-TEST WARNING (C shakli) |
| Qattiq jismli uzish chiqishi |
500 ms davomida 250 VDC da 15 A tokni ulash va o‘tkazish |
| Ketma-ket aloqa |
RS232 (old panel), RS485 / RS422 (orqa panel), 300–19 200 bod |
| Ethernet aloqasi |
10BaseT, RJ45 ulagichi, TCP/IP orqali ModBus RTU |
| Qo‘llab-quvvatlanadigan protokollar |
ModBus RTU, DNP 3.0 Level 2, ModBus RTU TCP/IP |
| Ishlash harorati diapazoni |
-40 darajaC dan +60 darajaC gacha |
| Saqlashdagi atrof-muhit harorati |
-40 darajaC dan +85 darajaC gacha |
| Namlik darajasi |
55 darajaC da 95% gacha (kondensatsiyasiz) ishlash |
| Himoyani ta’minlash darajasi |
IP40 (old qism), IP20 (orqa qism) |
| Ifloslanish darajasi |
2 |