Honeywell 05701-A-0327 System 57 ikki tomonlama SPCO rele kartasi
SKU 05701-A-0327
In stock
No reviews
12-month warranty
Free returns within 30 days
Manufacturer:
Honeywell
Product No.:
05701-A-0327
Country of origin:United States
Product Type:
Rele interfeys kartalari
Payment:
T/T, Western Union
Weight:
500g
Dimensions:
112 mm x 25 mm x 102 mm
Shipping port:
Xiamen
Warranty:
12 months
Honeywell 05701-A-0327 System 57 Double SPCO Relay Card
Tavsif
Honeywell 05701-A-0327 — System 57 / 5701 Series Control System uchun mo‘ljallangan plagin interfeys va boshqaruv konturi moduli. Ushbu apparat moduli, avvalo, sanoat gaz sensorlari va ularga biriktirilgan Single Channel Control Cards o‘rtasida ulanishni ta’minlovchi elektr ko‘prigi vazifasini bajaradi. Uzluksiz gaz ko‘rsatkichi va protsessor mantiqini fizik dala simlaridan ajratish orqali karta alohida monitoring tugunlarida kontur yaxlitligini ta’minlaydi.
Standart sensor signal yo‘llarini yo‘naltirishdan tashqari, modul tashqi signalizatorlar yoki himoya o‘chirish tizimlarini boshqarish uchun kuchlanishsiz kontakt chiqishlarini ta’minlaydigan bir qutbli almashuvchi (SPCO) elektromexanik relelarga ega. Ushbu integratsiyalangan rele kontaktlari muayyan xavf indekslarini kuzatish uchun doimiy ravishda yoki obyekt sharoitida sozlanadi va A1 signali darajasi, A2 signali darajasi hamda mahalliy nosozlik holati yo‘llari uchun diskret chegaralar bo‘yicha uzluksiz ishlaydi. Fizik joylashuv yuqori zichlikdagi DIN-reykali rack yig‘ilmalari uchun optimallashtirilgan bo‘lib, ikki kamerali ajratish dizayni mahalliy elektromagnit anomaliyalarni tabiiy ravishda susaytiradi.
Xususiyatlari
Tashqi dala infratuzilmasiga bevosita xavfsiz kuchlanishsiz kontakt chiqishlarini taqdim etuvchi, yuqori ishonchlilikka ega bir qutbli almashuvchi (SPCO) relelarni o‘z ichiga oladi.
Uchta alohida kuzatuv mezoni bo‘yicha individual signal konturlarini qayta ishlaydi: A1 signali, A2 signali va nosozlik holati.
Sub-rack korpusi ichida kabel ekranini bevosita toza tarzda drenajlashni osonlashtiruvchi integratsiyalangan yerga ulash yo‘liga ega.
Mavjud backplane quvvat shinasini o‘zgartirmasdan slotga muammosiz o‘rnatish imkonini beruvchi ixcham 3U Eurocard formatida ishlab chiqilgan.
Old va orqa sub-rack kirish konfiguratsiyalari uchun aniq belgilangan foydalanuvchi havolalarini aks ettiruvchi mustaqil klemma bloklari bilan qurilgan.
Qo‘llanilishi
Mahalliy A1 va A2 xavf sirenalari yoki ogohlantiruvchi stroboskop nurlari uchun fizik kontaktlarni takrorlashni talab qiladigan taqsimlangan gaz monitoringi massivlari.
Sanoat ulash shkaflaridagi analog xavfsizlik ko‘rsatkichlarini masofaviy PLC yoki DCS monitoring tizimlariga bog‘lovchi interfeysni yakunlash matritsalari.
Neft va gaz qazib olish muhitlari yoki suvni tozalash inshootlarida past kuchlanishli dala xavfsizlik signallarini qayta ishlovchi maxsus boshqaruv konturlari.
Maksimal 5A (tarmoqdagi AC kuchlanishlarni ulashda)
Balandligi
112 mm
Eni
25 mm
Chuqurligi
102 mm
Tashish vazni
2 kg
Ulanishlar/interfeyslar
Ulagich pini
Funksiya
TB1 - PSU (+)
Asosiy tashqi 24V DC quvvat ta’minoti qurilmasining musbat ulanish kirishi
TB1 - PSU (-)
Asosiy tashqi 24V DC quvvat ta’minoti qurilmasining manfiy umumiy tayanch qutbi
TB1 - AUX (+)
Kutish rejimidagi zaxira akkumulyator saqlash quvvat ta’minotining musbat ulanish kirishi
TB1 - AUX (-)
Kutish rejimidagi zaxira akkumulyator saqlash quvvat ta’minotining manfiy umumiy tayanch qutbi
TB1 - GND
Past impedansli, maxsus asboblar uchun toza yer ekran ulanishi
Orqa tomondan ulanishlar
Foydalanuvchi terminali ma’lumotnomasi
Ulagich pini / Funksiya
Yer
26 / Ekran yerga ulash yo‘li
Sensor S ulanishi
25 / Sensor ta’minot liniyasi
Sensor NS ulanishi
27 / Sinksiz / signalni qaytarish liniyasi
Sensor 01 ulanishi
28 / Sensorning 0V tayanch liniyasi
Analog chiqish (+)
29 / Izolyatsiyalangan tok halqasi chiqishining musbat qutbi
Analog chiqish (-)
32 / Izolyatsiyalangan tok halqasi chiqishining manfiy qutbi
Masofaviy bloklash kirishi
31 / Tashqi kanalni bloklash signali
Masofaviy tiklash kirishi
34 / Tashqi signalizatsiyani tiklash buyruq liniyasi
+24V (Chiqish/Kirish)
33 / Tizimning 24V DC yordamchi liniyasi
0V (Chiqish/Kirish)
36 / Tizimning 0V DC yordamchi umumiy liniyasi
Nosozlik NC
1 / Nosozlik relesining odatda yopiq terminali
Nosozlik NO
2 / Nosozlik relesining odatda ochiq terminali
Nosozlik COM
3 / Nosozlik relesining umumiy yo‘li
A1(1) NC
7 / A1 signalizatsiyasining odatda yopiq kontakti
A1(1) NO
8 / A1 signalizatsiyasining odatda ochiq kontakti
A1(1) COM
9 / A1 signalizatsiyasining umumiy yo‘li
A2(1) NC
11 / A2 signalizatsiyasining odatda yopiq kontakti
A2(1) NO
12 / A2 signalizatsiyasining odatda ochiq kontakti
A2(1) COM
10 / A2 signalizatsiyasi umumiy yo‘li
Old tomondan ulanishlar
Foydalanuvchi terminali ma’lumotnomasi
Ulagich pini / Funksiya
0V (Chiqish/Kirish)
36 / Tizimning 0V DC yordamchi umumiy liniyasi
+24V (Chiqish/Kirish)
35 / Tizimning 24V DC yordamchi liniyasi
Masofaviy tiklash kirishi
34 / Tashqi signalizatsiyani tiklash buyruq liniyasi
Masofaviy bloklash kirishi
33 / Tashqi kanalni bloklash signali
Analog chiqish (-)
32 / Izolyatsiyalangan tok halqasi chiqishining manfiy qutbi
Analog chiqish (+)
31 / Izolyatsiyalangan tok halqasi chiqishining musbat qutbi
Sensor 01 ulanishi
30 / Sensorning 0V tayanch liniyasi
Sensor NS ulanishi
29 / Sinksiz / signalni qaytarish liniyasi
Yer
28 / Ekran yerga ulash yo‘li
Sensor S ulanishi
27 / Sensor ta’minot liniyasi
Yer
26 / Muqobil ekran yerga ulash terminali
Yer
25 / Muqobil ekran yerga ulash terminali
Nosozlik NC
1 / Nosozlik relesining odatda yopiq terminali
Nosozlik NO
2 / Nosozlik relesining odatda ochiq terminali
Nosozlik COM
3 / Nosozlik relesining umumiy yo‘li
A1(1) NC
5 / A1 signalizatsiyasining odatda yopiq kontakti
A1(1) NO
8 / A1 signalizatsiyasining odatda ochiq kontakti
A1(1) COM
9 / A1 signalizatsiyasining umumiy yo‘li
A2(1) NC
11 / A2 signalizatsiyasining odatda yopiq kontakti
A2(1) NO
12 / A2 signalizatsiyasining odatda ochiq kontakti
A2(1) COM
10 / A2 signalizatsiyasi umumiy yo‘li
O‘rnatish bo‘yicha yo‘riqnoma
Tarmoq kuchlanishini ulash xavfsizligi: Rele klemalari orqali tarmoqdagi o‘zgaruvchan tok infratuzilmasi kiritilganda, tashqi o‘zgaruvchan tok ta’minoti liniyalari maksimal 5 A saqlagich bilan qat’iy cheklanganini tekshiring.
Himoya yerga ulash: Kontaktlarga yuqori kuchlanishli liniyalar ulanganida, yuqori ishonchlilikdagi himoya yerga ulash simi bevosita rele kartasining maxsus yerga ulash shtifti klemmasiga ulanadi.
Kabel yo‘nalishlarini ajratish: Nozik o‘lchash yo‘llarida parazit kuchlanish shovqinini yuzaga keltirmaslik uchun barcha boshqaruv relesi kontaktlari simlari yo‘nalishlarini yuqori sezgirlikdagi sensor signal liniyalaridan ajrating.
Ekranni bir uchidan ulash: Mahalliy yerga ulash shtiftlariga yoki po‘lat konstruksiyalarga mahkamlangan dala gaz detektorlari uchun xavfli yer konturi maydonlari hosil bo‘lishining oldini olish maqsadida kabel ekran qobig‘ini faqat bir uchidan — sensor korpusiga yoki rele interfeys kartasiga — ulang.
Issiq almashtirish blokirovkalari: Alohida kanal boshqaruv kartalarini orqa interfeys klemalariga ulangan faol dala yoki rele simlariga xalaqit bermasdan, sub-rakning old tomonidan chiqarish mumkin.
Ko‘p so‘raladigan savollar
A1 va A2 signalizatsiya relelari kontaktlarining yo‘nalishlari qanday aniqlanadi?
Odatda yopiq (NC) va odatda ochiq (NO) holatlar uchun hujjatlarda keltirilgan klemma tavsiflari boshqaruv moduli to‘liq quvvatsizlangan, elektr ta’minotisiz holatiga mos keladi.
Plata ichidagi FAULT rele zanjirining standart ishlash rejimi qanday?
FAULT relesi qurilma normal, nosozliksiz holatda bo‘lganda odatda quvvatlangan rejimda ishlash uchun qattiq simli ulangan; bu boshqaruv halqasidagi quvvatning to‘liq uzilishi xavfsiz holatdagi tizim signalizatsiyasi ishga tushishiga sabab bo‘lishini ta’minlaydi.
Signalizatsiya relesining ishga tushish rejimlarini odatda quvvatlangan mantiqqa moslab o‘zgartirish mumkinmi?
Ha, markaziy Engineering Interface Software dasturi orqali sozlamalarni yangilash natijasida A1 va A2 signalizatsiya relelarini odatda quvvatlangan yoki odatda quvvatsizlangan ishlash rejimiga alohida qayta sozlash mumkin.
Ushbu interfeys moduli qalinroq, yuqori tokli sanoat simlarini qabul qiladimi?
Interfeys karta yig‘masidagi o‘rnatilgan mexanik siqish klemalari maksimal kesim yuzasi 2,5 mm2 bo‘lgan bir yoki ko‘p tomirli asbobsozlik kabellarini ulash uchun mo‘ljallangan.
Product Documentation
Technical Datasheet (PDF)Complete specifications and technical drawings.
Chiziq reaktorlari, garmonik filtrlar, chiqish reaktorlari, dV/dt filtrlari va sinusoidal filtrlar turli VFD elektr sifati hamda motor kabellari muammolarini qanday hal qilishini va ularni xavfsiz...
Yorug‘likda ishga tushuvchi va qorong‘ilikda ishga tushuvchi fotoelektrik datchik rejimlarining to‘siq nurli, retroreflektorli va diffuz sezish, PNP/NPN ulanishi, PLC mantiqi, ishga tushirish hamda...
H-bridge motor drayverlari bo‘yicha amaliy qo‘llanma: kommutatsiya holatlari, o‘lik vaqt, induktiv tok yo‘llari, PWM tanlovlari, himoya, PCB joylashuvi, PLC bilan interfeys va bosqichma-bosqich ishga...
Mitsubishi FX PLC STL va RET ko‘rsatmalari konveyer va pnevmatik ketma-ketliklarni qanday tuzishini amaliy holat dizayni, o‘tish mantiqi, vaqt tugashi nazorati, diagnostika va xavfsiz qayta ishga...
DIN uslubidagi klapan ulagichlarini tanlash, ulash va diagnostika qilish bo‘yicha amaliy qo‘llanma: shaklni aniqlash, g‘altak kuchlanishi, so‘ndirish, qutblilik, germetiklik, ishga tushish vaqti...
PLC va mikrokontroller ikkalasi ham qadam va yo‘nalish signallari asosidagi harakatni hosil qila oladi, biroq yoyli payvandlash EMC, I/O himoyasi, diagnostika, texnik xizmat ko‘rsatish qulayligi,...
Choosing a selection results in a full page refresh.