1 of 1

Honeywell CC-PWRR01 C300 Redundant Power Supply Module

Honeywell CC-PWRR01 C300 Redundant Power Supply Module

Only 7 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: CC-PWRR01

  • Country of origin:United States

  • Product Type: PLC Power Supply Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 250 x 180 x 120 mm (9.84 x 7.09 x 4.72 in)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Delivering regulated, highly reliable power distribution within the Experion C300 controller subsystem, the Honeywell CC-PWRR01 functions as a dual-channel redundant power source designed to protect critical process control loops from input line failures. This module integrates directly into the Series C power carrier assemblies, allowing for seamless load-sharing, active diode auctioning, and uninterrupted power handovers. Engineered specifically to meet the high-availability demands of modern continuous process environments, the Honeywell CC-PWRR01 stabilizes system voltages, filters electromagnetic interference, and provides real-time diagnostic status feedback directly to the controller architecture.

Features

  • Active Redundant Load-Sharing: Seamlessly balances the current demand between paired power modules to extend component lifecycle and ensure zero-millisecond failover.
  • Hot-Swappable Architecture: Permits safe removal and replacement of a faulted power supply module while the process system remains fully energized.
  • Diagnostic Status Indication: Front-panel LEDs provide immediate, clear visual states of input power viability, output regulation, and over-temperature faults.
  • Integrated Diode Auctioning: Eliminates the risk of back-feeding or circuit disruption in the event of an internal component short-circuit.
  • Heavy-Duty Industrial Filtering: Built-in transient voltage surge suppression (TVSS) shields downstream C300 controllers and Series C I/O modules from grid irregularities.

Applications

  • Petrochemical refining and high-availability chemical synthesis plants.
  • Base-load and peak-generation thermal and combined-cycle power facilities.
  • Continuous process pulp, paper, and metallurgy control networks.
  • Offshore oil platform Emergency Shutdown (ESD) and Fire & Gas (F&G) systems.

Technical Specifications

Parameter Value / Specification
Manufacturer Honeywell
Model Number CC-PWRR01
System Compatibility Experion C300 / Series C I/O
Output Voltage 24 VDC nominal
Configuration Redundant (requires matching module on compatible carrier)
Cooling Method Natural convection
Operating Temperature 0 to 60 degC (32 to 140 degF)
Storage Temperature -40 to 85 degC (-40 to 185 degF)
Relative Humidity 5% to 95% non-condensing
Country of Origin United States / Global OEM sites
Shipping Weight (Calculated) 2.00 kg (4.41 lbs)
Package Dimensions (Calculated) 250 x 180 x 120 mm (9.84 x 7.09 x 4.72 in)

Connections and Interfaces

Connection Point Function / Circuit Assignment
Backplane Connector High-current blind-mate interface interfacing directly with the power carrier bus bars.
Status LED Array Visual indicators for Input OK (Green), Output OK (Green), and Module Fault/Over-Temp (Red).

Empirical Engineering Insights

Alternative Models & Compatibility

The CC-PWRR01 is designed specifically for insertion into the CC-PWRB01 (or equivalent) redundant power carrier. When performing system upgrades or migrations from legacy Experion platforms, verify that your existing carrier backplane is rated to accept Series C Form-Factor modules, as keying pins prevent physical mismating with non-compatible I/O racks.

Application Pitfalls & Engineering Notes

To guarantee optimal MTBF, maintain at least 50mm of clear space above and below the power carrier assembly to allow unobstructed convective airflow. In highly enclosed or non-ventilated field cabinets, thermal concentration can cause premature aging of the internal electrolytic capacitors. Always implement external ambient monitoring within the cabinet to ensure temperatures do not exceed the 60 degC threshold.

Commissioning & Wiring Tips

When bringing a redundant pair online, energize the primary and secondary power sources from isolated feed breakers. This layout ensures that an upstream breaker trip on Feed A does not compromise Feed B. Utilize the dry-contact alarm terminal block on the redundant carrier to route power fail status signals back to your diagnostic alarm logs in Experion PKS.

Installation Guidelines

CRITICAL WARNING: Ensure all incoming primary AC or DC power feeds are locked out, tagged out, and verified de-energized prior to installing, removing, or wiring any power carrier components. Working on live terminations poses severe flashover, shock, and equipment damage risks.
1
Mount the compatible Series C Redundant Power Carrier securely to the standard 35mm DIN rail or cabinet backplate using rugged grounding screws.
2
Align the CC-PWRR01 module with the dedicated slot guides on the carrier card. Slide the unit firmly until the blind-mate backplane connectors fully seat and the retaining mechanism clicks into place.
3
Connect your input feed wires to the respective terminal terminals on the carrier block, verifying torque settings match Honeywell installation specs. Do not over-tighten.
4
Apply power to Feed A and verify the corresponding LED lights up Green. Repeat for Feed B, ensuring both modules operate in active load-sharing configuration.

Can I hot-swap the CC-PWRR01 module while the C300 controller is running?

Yes. This power supply supports full hot-swap capability when installed on a redundant carrier backplane. The sister module will immediately shoulder the entire current load without interruption.

What is the primary indicator of a complete unit failure on this module?

An internal fault or over-temperature condition is indicated by a solid red LED on the front panel, and the Output OK green LED will turn off.

Is external diode protection required for redundant configurations?

No. The module features integrated auctioning diodes designed to prevent back-feeding, making external diode modules unnecessary.

How should I handle thermal management when mounting multiple modules?

Ensure a minimum of 50mm spacing above and below the power carrier assembly to facilitate natural air convection and prevent heat buildup.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

OpenVMS Alpha da ishlayotgan Bailey INFI 90 Symphony HMI larini zamonaviylashtirish

OpenVMS Alpha asosida ishlayotgan eskirgan Bailey Symphony operator stantsiyalarini almashtirish bo‘yicha amaliy qo‘llanma. Unda Alpha emulyatsiyasi, OpenVMS x86 ga ko‘chirish, OPC platformasini...

Nima uchun texnik xizmat ko‘rsatish ma’lumotlari sanoat ishonchliligi uchun muhimdir

Texnik xizmat ko‘rsatish ma’lumotlari ish buyurtmalari, sensor signallari, aktivlar tarixi, xarajatlar va texnik mutaxassislarning bilimlarini bog‘laydi. To‘g‘ri ishlatilganda, u rejalashtirish,...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...