Honeywell FS-SICC-0001/L20 Safety Manager System Interconnection Cable

Honeywell FS-SICC-0001/L20 Safety Manager System Interconnection Cable

Only 7 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: FS-SICC-0001/L20

  • Country of origin:United States

  • Product Type: Interconnection Cables

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for secure signal transmission within safety-instrumented systems, the FS-SICC-0001/L20 serves as a reliable physical link in industrial control environments. This pre-fabricated system interconnection cable establishes a direct connection between Honeywell Safety Manager I/O modules and Field Termination Assemblies (FTAs). By utilizing specialized connectors on both ends, it minimizes installation time and eliminates point-to-point wiring errors in high-integrity automation cabinets.

The cable assembly is engineered to maintain signal integrity across its 20-meter length, making it ideal for distributed control architectures and multi-cabinet safety systems. Its robust design supports critical applications where system uptime and deterministic response times are paramount.

Features

  • Pre-assembled dual-connector layout ensures fast and error-free commissioning.
  • Equipped with a specialized I/O module interface on one end and a standard 20-pin FTA connector on the opposing end.
  • Generous 20-meter length facilitates routing across large control cabinets and separation zones.
  • Durable insulation jacket designed to withstand typical industrial panel conditions.

Applications

  • Honeywell Safety Manager ESD (Emergency Shutdown) system integration.
  • Fire and Gas (F&G) system loop wiring.
  • Burner Management Systems (BMS) in petrochemical, power generation, and refining plants.
  • Connecting safety-critical I/O cards to field termination interfaces.

Technical Specifications

Manufacturer Honeywell
Part Number FS-SICC-0001/L20
System Compatibility Safety Manager
Cable Type System Interconnection Cable
Length 20 meters
Connector End A Dedicated I/O Connector
Connector End B 20-pin FTA Connector
Weight 2.0 kg

Connections and Interfaces

Connection End Interface Type Destination Pinout/Format
End A I/O Module Connector Safety Manager I/O Module Interface
End B FTA Connector 20-pin Field Termination Assembly

Installation Guidelines

  • Observe standard bending radius guidelines during cable routing to prevent internal conductor strain or signal degradation.
  • Avoid routing the interconnection cable parallel to high-voltage or high-current power cables to reduce the risk of electromagnetic interference.
  • Ensure the retention mechanisms on both the I/O module and FTA connectors are fully locked to guarantee physical connection stability under vibration.

What is the primary function of the Honeywell FS-SICC-0001/L20 cable?

The FS-SICC-0001/L20 connects Honeywell Safety Manager I/O modules directly to Field Termination Assemblies (FTAs).

How long is the FS-SICC-0001/L20 cable?

This system interconnection cable has a pre-fabricated length of 20 meters.

What are the connection interfaces on either end of the cable?

It features a specialized I/O module connector on one end and a 20-pin FTA connector on the other.

Can this cable be used in Safety Manager emergency shutdown systems?

Yes, it is designed specifically for integration within Safety Manager systems, including ESD, F&G, and BMS applications.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...