1 of 1

Omron G3PE-225B-3N | Omron | Solid State Contactors for Three-phase Heaters

Omron G3PE-225B-3N | Omron | Solid State Contactors for Three-phase Heaters

Only 7 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: G3PE-225B-3N

  • Country of origin:Japan

  • Product Type: Three-phase Solid State Contactors for Heaters

  • Payment: T/T, Western Union

  • Weight: 2500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The G3PE-225B-3N is a high-performance three-phase solid state contactor designed specifically for controlling industrial heating loads. Utilizing a phototriac coupler for insulation, this solid state relay (SSR) provides rapid, maintenance-free switching without the wear associated with mechanical contactors. The unit features an integrated zero cross function, which minimizes inrush current and electromagnetic interference during switching, protecting the heater elements and prolonging system lifespan. Optimized for high-density industrial control panels, it supports DIN track mounting and provides reliable operation for three-phase heater applications requiring a 25 A load capacity.

Features

  • Three-phase control optimized for industrial heaters
  • Insulation Method: Phototriac coupler
  • Integrated zero cross function for reduced electrical noise
  • Built-in operation indicator (yellow LED) for status monitoring
  • Compact design suitable for DIN track mounting

Applications

  • Industrial oven and furnace temperature control
  • Plastic molding and extrusion heating systems
  • Commercial food processing equipment
  • Packaging machinery heat sealing

Technical Specifications

Parameter Specification
Manufacturer Omron
Model G3PE-225B-3N
Product Type Three-phase Solid State Contactor
Rated Input Voltage 12 to 24 VDC
Applicable Load 25 A, 100 to 240 VAC
Number of Phases Three-phase
Insulation Method Phototriac coupler
Zero Cross Function Yes
Mounting Type DIN track
Operation Indicator Yes (Yellow)
Shipping Weight 2.5 kg

Installation Guidelines

  • Mounting: Ensure the device is mounted on a standard DIN rail in a vertical orientation to facilitate natural convection cooling.
  • Heat Dissipation: Solid state contactors generate heat during operation. Maintain adequate clearance from other components to ensure sufficient airflow.
  • Wiring: Use appropriately sized conductors for the 25 A load. Ensure all terminal connections are tightened to the torque specifications provided in the installation manual.
  • Protection: It is recommended to install a fast-acting fuse in series with the load to provide short-circuit protection for the output semiconductors.

What is the function of the zero cross feature in the G3PE-225B-3N?

The zero cross function switches the output when the AC load voltage is near zero, which significantly reduces inrush current and electrical noise generated during switching.

What type of mounting does this solid state contactor support?

The G3PE-225B-3N is specifically designed for convenient DIN track mounting.

What is the load capacity of this unit?

This contactor is rated for an applicable load of 25 A at 100 to 240 VAC.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
Japan

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...