1 of 1

Schneider Electric Altistart 22 ATS22D75S6U Soft Starter

Schneider Electric Altistart 22 ATS22D75S6U Soft Starter

Only 6 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: ATS22D75S6U

  • Country of origin:France

  • Product Type: Soft starters

  • Payment: T/T, Western Union

  • Weight: 8530g

  • Dimensions: 31cm x 36cm x 23cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The ATS22D75S6U is a Schneider Altistart 22 Soft Starter engineered for the controlled starting and stopping of three-phase asynchronous motors. Designed to reduce mechanical stress and electrical surges during motor startup, this soft starter manages a nominal current of 75 A and operates across a wide voltage range of 208V to 600V. It provides power control for motors rated between 20 HP and 60 HP, depending on the application voltage. The ATS22D75S6U features integrated bypass contactors and comprehensive protection functions to safeguard motors and machinery from overload, phase failure, and phase imbalance.

Features

  • Nominal current rating: 75 A
  • Wide operating voltage: 208V to 600V AC
  • Power compatibility: 20 HP to 60 HP
  • Integrated bypass contactor to reduce heat dissipation
  • Comprehensive motor protection features (overload, phase imbalance)
  • Compact design optimized for space-saving panel installation

Applications

  • Centrifugal and axial pumps
  • Ventilation and exhaust fans
  • Compressors
  • Conveyor systems
  • Industrial mixers and agitators

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Altistart
Subrange 22
Product Type Soft Starter
Nominal Current 75 A
Voltage Range 208 - 600V AC
Power Rating 20 - 60 HP
Dimensions 31.00 x 36.00 x 23.00 cm
Weight 8.53 kg
Commodity Code 84798997
Export Control (ECCN) N

Installation Guidelines

  • Mounting: Install the soft starter in a vertical orientation within an enclosure that provides adequate ventilation. Ensure sufficient clearance is maintained above and below the unit to allow for convective cooling.
  • Environmental: Ensure the installation environment is free from dust, moisture, and corrosive gases. Use an enclosure with the appropriate IP rating for the specific application environment.
  • Wiring: Connect the line supply (L1, L2, L3) and motor terminals (T1, T2, T3) using appropriately sized power conductors as specified in the local electrical code.
  • Grounding: Secure a solid connection to the cabinet's main protective earth (PE) bus to ensure electrical safety and effective noise mitigation.
  • Configuration: Utilize the integrated keypad or communication interface to set starting parameters (torque ramp and voltage limit) tailored to the specific load characteristics of the motor.

What is the function of an Altistart 22 soft starter?

It provides a controlled voltage ramp during motor startup and shutdown to reduce mechanical wear and limit electrical current spikes.

What motors can be controlled by the ATS22D75S6U?

It is designed for three-phase asynchronous motors within the range of 20 HP to 60 HP, depending on the line voltage.

Does this unit require an external bypass contactor?

No, the Altistart 22 features an integrated internal bypass contactor to reduce heat and improve system efficiency.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
France
Power source
AC-powered

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...