Tavsif
Siemens 6ES7716-2DB10-0DC4 — sanoat avtomatlashtirish vazifalari uchun mo‘ljallangan SIMATIC Field PG M4 Premium plus dasturlash qurilmasi. Ushbu mustahkam qurilma Intel Core i7-35X0M protsessori (2,9 GHz, Turbo Boost texnologiyasi bilan 3,6 GHz gacha va 4 MB kesh), HD Graphic 4000 hamda 480 GB SATA qattiq holatli disk bilan jihozlangan. Unda integratsiyalangan DVD RW optik disk qurilmasi va 15,6 dyuymli Full HD (1920x1080) displey mavjud. Qurilma S5 interfeysi va S5-EPROMMER, shuningdek, eski tizimlarni qo‘llab-quvvatlash uchun S5-AG kabeli hamda EPROM adapteri bilan jihozlangan. Ulanish uchun MPI kabeli ham kiritilgan. Qurilma nemischa belgilar mavjud QWERTY klaviaturaga ega va turli Yevropa hududlari (DE, FR, NL, SP, BEL, OES, SWD, FIN) uchun mos tarmoq kabeli bilan ta’minlangan. Field PG M4 oldindan o‘rnatilgan Windows XP Professional SP3 va Windows 7 Ultimate SP1 (64-bit) bilan ikki yuklanishli konfiguratsiyani qo‘llab-quvvatlaydi hamda 8 GB tezkor xotira bilan to‘ldirilgan. U Siemens muhandislik dasturlari, jumladan STEP7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0 va STEP 5 uchun litsenziyalarni o‘z ichiga oladi; dasturiy ta’minot versiyasi V13.0.1.0.
Xususiyatlar
- Intel Core i7-35X0M protsessori (2,9 GHz, Turbo Boost bilan 3,6 GHz gacha)
- 15,6 dyuymli Full HD (1920x1080) displey
- 480 GB SATA qattiq holatli disk
- 8 GB tezkor xotira
- Ikki yuklanishli operatsion tizim (Windows XP Professional SP3 / Windows 7 Ultimate SP1 64-bit)
- S5-EPROMMER bilan integratsiyalangan S5 interfeysi
- Oldindan o‘rnatilgan dasturiy ta’minot litsenziyalari (STEP7 Prof combo, WinCC Advanced combo, STEP 7 Micro/WIN V4.0, STEP 5)
- DVD RW optik disk qurilmasi
- HD Graphic 4000
- S5-AG kabeli, EPROM adapteri va MPI kabeli bilan birga
Ilovalar
SIMATIC Field PG M4 sanoat avtomatlashtirishining quyidagi kabi turli ilovalari uchun mos keladi:
- SIMATIC S5 va S7 PLC qurilmalarini dasturlash va sozlash.
- WinCC Advanced va WinCC flexible yordamida HMI loyihalarini ishlab chiqish va ishga tushirish.
- Avtomatlashtirish tizimlarini joyida diagnostika qilish, texnik xizmat ko‘rsatish va nosozliklarni bartaraf etish.
- Eski SIMATIC S5 qurilmalarini yangilash va ularga texnik xizmat ko‘rsatish.
- Mustahkam va ko‘chma hisoblash platformasini talab qiladigan umumiy sanoat muhandislik va ishlab chiqish vazifalari.
Texnik xususiyatlar
| Ishlab chiqaruvchi |
Siemens |
| Turkum |
SIMATIC Field PG |
| Quyi turkum |
Field PG M4 |
| Mahsulot turi |
Premium dasturlash qurilmasi |
| Mahsulot holati |
Ishlab chiqarishdan chiqarilmoqda |
| Protsessor |
Intel Core i7-35X0M |
| Protsessor tezligi |
2,9 GHz (Turbo Boost bilan 3,6 GHz gacha) |
| Protsessor keshi |
4 MB |
| Tezkor xotira |
8 GB |
| Xotira |
480 GB SATA qattiq holatli disk |
| Optik disk qurilmasi |
DVD RW |
| Grafika |
HD Graphic 4000 |
| Displey o‘lchami |
15.6 dyuym |
| Displey aniqligi |
Full HD (1920 x 1080) |
| Klaviatura joylashuvi |
QWERTY (nemischa belgilar bilan) |
| Operatsion tizim |
Ikkita yuklanish (Windows XP Professional SP3, Windows 7 Ultimate SP1 64-bit) |
| Oldindan o‘rnatilgan dasturiy ta’minot |
STEP7 Prof combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, STEP 5 |
| Dasturiy ta’minot versiyasi |
V13.0.1.0 |
| Komplektdagi kabellar/adapterlar |
S5-AG kabeli, EPROM adapteri, MPI kabeli, elektr kabeli (DE, FR, NL, SP, BEL, OES, SWD, FIN) |
| Tovar kodi |
84713000 |
| Eksport nazorati qoidalari (ECCN) |
N |
| Qadoq o‘lchamlari (hisoblangan) |
39.50 x 30.00 x 17.00 cm |
| Yetkazib berish og‘irligi |
3.50 kg |
Ulanishlar / interfeyslar
| Interfeys turi |
Funksiya |
| S5 interfeysi |
SIMATIC S5 PLC’lariga ulanish va S5-EPROMMER funksiyasi uchun |
| MPI interfeysi |
SIMATIC S7 PLC’lari va HMI’lariga komplektdagi MPI kabeli orqali ulanish uchun |
| DVD RW optik disk qurilmasi |
Dasturiy ta’minotni o‘rnatish va ma’lumotlarni zaxiralash uchun |
O‘rnatish bo‘yicha ko‘rsatmalar
-
Quvvat ulanishi: Field PG M4’ni hududingiz uchun mos elektr kabelidan foydalanib, barqaror quvvat manbaiga ulang. Shikastlanishning oldini olish uchun quvvat manbai qurilma talablariga javob berishiga ishonch hosil qiling.
-
Atrof-muhit sharoitlari: Qurilmani belgilangan harorat va namlik diapazonlarida ishlating. Sanoat muhitiga xos chang, namlik va ortiqcha tebranishlarning bevosita ta’siridan saqlang.
-
Dasturiy ta’minotni sozlash: Dastlabki ishga tushirishda ikkita yuklanishli operatsion tizim konfiguratsiyasini tekshiring. Oldindan o‘rnatilgan barcha Siemens muhandislik dasturlari (STEP7, WinCC, STEP 5) to‘g‘ri litsenziyalanganini va loyihalaringiz uchun mos eng so‘nggi versiyaga yangilanganini tekshiring.
-
Periferik ulanishlar: SIMATIC S5 dasturlash uchun S5-AG kabeli va EPROM adapterini ulang. SIMATIC S7 PLC’lari yoki HMI’lariga ulanish uchun MPI kabelidan foydalaning. Barcha kabellar mahkam mahkamlanganiga ishonch hosil qiling.
-
Ma’lumotlarni boshqarish: Ma’lumotlar yo‘qolishining oldini olish uchun loyiha ma’lumotlari va tizim konfiguratsiyalarini muntazam ravishda tashqi xotiraga zaxiralang. Faol loyihalar uchun 480 GB SSD’dan samarali foydalaning.
-
Xavfsizlik: Kuchli parollar va tarmoqni segmentatsiyalashni o‘z ichiga olgan tegishli kiberxavfsizlik choralarini ko‘ring, ayniqsa zavod tarmoqlariga ulanganda.
-
Texnik xizmat: To‘g‘ri havo oqimini ta’minlash uchun qurilmaning sovitish ventilyatsiyasi teshiklarini to‘siqlardan xoli saqlang. Dasturiy ta’minot yangilanishlari va tizim holatini muntazam tekshirib turing.