1 trong số 1

B&R X20AI4622 X20 Series Analog Input Module

B&R X20AI4622 X20 Series Analog Input Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20AI4622

  • Country of origin:Hoa Kỳ

  • Product Type: Control systems

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Product Overview

The B&R X20AI4622 (X20 AI 4622) is a high-performance analog input module designed for precision process monitoring within the B&R X20 automation system. Engineered for demanding industrial environments—including power generation plants, chemical processing facilities, and automated manufacturing lines—this module provides 4 differential inputs capable of handling both current and voltage signals. By delivering reliable, high-resolution signal acquisition, the X20AI4622 significantly reduces sensor-to-controller latency and mitigates the risk of unscheduled downtime caused by signal inaccuracies. Its compact design and modular architecture ensure seamless integration into existing control cabinets, providing the robust data fidelity required for complex closed-loop control applications.

Technical Configuration

The module features a high-precision 13-bit digital converter (including sign) based on the Successive Approximation Register (SAR) conversion procedure. It is built for versatility, allowing the user to switch between voltage (plus/minus 10 V) and current (0 to 20 mA or 4 to 20 mA) modes simply by selecting the appropriate terminal connection points. The module is engineered with a 3rd-order low-pass input filter with a cutoff frequency of 1 kHz to eliminate high-frequency noise from industrial machinery. Electrical isolation is provided between the I/O channels and the backplane bus, protecting the CPU and downstream processing components from potential transients. Status monitoring is comprehensive, with integrated LEDs for channel-specific I/O functions and module-wide error diagnostics accessible via software.

Technical Specifications

Feature Specification
Model X20AI4622
Brand B&R
Analog Inputs 4 Differential
Resolution 13-bit (including sign)
Conversion Time 400 microseconds
Input Impedance (Voltage) 20 MOhm
Input Protection Max plus/minus 30 V (Voltage) / Max plus/minus 50 mA (Current)
Bus Power Consumption 0.01 W
Internal I/O Power 1.1 W
Operating Temperature -25 to 60 deg C (Horizontal)
Protection Rating IP20
Weight 1.0 kg

FAQs

Is the X20AI4622 compatible with all X20 series backplanes?

Yes, it is designed for the standard X20 system architecture, but you must order the X20BM11 bus module and X20TB12 terminal block separately as they are not included with the module.

How do I switch between voltage and current input modes?

The selection is hardware-dependent. You must wire the input signal to the specific terminal points designated for either voltage or current mode as outlined in the B&R user manual.

What is the recommended procedure if the module reports an overload?

The module is equipped with configurable diagnostics. When an overload is detected, the output of the digital value can be set via software configuration; check your software project settings to ensure the error-handling behavior matches your safety requirements.

Installation and Operational Guidelines

  • Wiring and Shielding: To ensure maximum signal integrity, always use shielded twisted-pair cables for analog signals. Ground the cable shield at one point—preferably at the entry to the control cabinet—to prevent ground loops that could interfere with the 13-bit conversion precision.
  • Thermal Management: When mounting the module in a cabinet, ensure a clearance of at least 12.5 mm to allow for proper airflow. If the installation altitude exceeds 2000 m above sea level, ensure the ambient temperature rating is derated by 0.5 deg C per 100 m to prevent thermal fatigue of the internal components.
  • Terminal Safety: The X20AI4622 is rated for hazardous locations (Class I, Division 2). Before servicing, ensure the environment is free of flammable gas concentrations and verify that the module is powered down before removing it from the X20BM11 bus module to prevent arcing.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Trắng xám
Country of origin
Hoa Kỳ
Power source
Nguồn điện DC

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...